Post on 07-Jul-2018
8/18/2019 7. Informe Inspección H- 1110 Rev1
1/6
1 of 6
Calibration Date: 2015-06-25
CS-2015- H-1110 REV 1
Page
CLIENT:
5 Mhz
EXAMINATED AREA (ITEMS)
Type/Model:
Weld
Butt weld's
TAG:
Other:
BEITE B&T CIA LTDA Order No.:
INSPECTION PLACE:
151/198
EQUIPMENT USED
EXAMINATION PERFORMED
N.A.
HEATER H-1110
PRESSURE VESSELH-1110
TC510 5MHZ SN16449
Examination of:
Equipment:
Fillet weld's
Thickness Control
HUATEC TG5000DL SN5500377 Transductor:
ULTRASONIC INSPECTION REPORT
Frecuence:
Other´s
Reference Document:
TG5000DL
PLANTA GNL BAJO ALTO
Model:
8/18/2019 7. Informe Inspección H- 1110 Rev1
2/6
Page 2 of 6
--- inches --- mm
0,468 inches 11,89 mm
1 2 3 4 5
0° 0,505 0,510 0,502 0,513 0,508
90° 0,495 0,505 0,498 0,515 0,510
180° 0,468 0,490 0,476 0,485 0,528
270° 0,495 0,505 0,498 0,515 0,510
Inspector, Level II
Name: Napoleón Tamayo
Date: Signature:2015-10-27
Measured Thickness (inches)
CS-2015- H-1110 REV 1
EXAMINATION REPORT
CLIENT: BEITE B&T CIA LTDA Order No. N.A.
ULTRASONIC INSPECTION A-SCAN
EXAMINATED ITEMS: SHELL
PLANTA GNL BAJO ALTO HEATER H-1110Design thickness:
Minimum measured thickness:
8/18/2019 7. Informe Inspección H- 1110 Rev1
3/6
Page 3 of 6
--- inches --- mm
0,625 inches 15,88 mm
1 2 3 4
0° 0,683 0,631 0,625 0,641
90° 0,631 0,630 0,630 0,627
180° 0,679 0,630 0,630 0,630
270° 0,670 0,639 0,638 0,631
Inspector, Level II
Name: Napoleón Tamayo
Date: Signature:2015-10-27
Measured Thickness (inches)
PLANTA GNL BAJO ALTO HEATER H-1110 Minimum measured thickness:
CLIENT: BEITE B&T CIA LTDA Order No. N.A.
EXAMINATED ITEMS: ELLIPTICAL HEAD (2) Design thickness:
ULTRASONIC INSPECTION A-SCANCS-2015- H-1110 REV 1
EXAMINATION REPORT
8/18/2019 7. Informe Inspección H- 1110 Rev1
4/6
Page 4 of 6
--- inches --- mm
--- inches --- mm
0° 90° 180° 270°
N1 - 3" 0,365 0,362 0,340 0,353
N2 - 3" 0,357 0,360 0,361 0,343
Inspector, Level II
Name: Napoleón Tamayo
Date: Signature:2015-10-27
CS-2015- H-1110 REV 1
EXAMINATION REPORT
CLIENT: BEITE B&T CIA LTDA Order No. N.A.
80
80
0,340
0,343
ULTRASONIC INSPECTION A-SCAN
EXAMINATED ITEMS: MANHOLES & NOZZLES Design thickness:
PLANTA GNL BAJO ALTO HEATER H-1110 Minimum measured thickness:
Measured Thickness (inches)Minimum measured thickness (inches)Schedule
8/18/2019 7. Informe Inspección H- 1110 Rev1
5/6
Page 5 of 6
--- inches --- mm
0,455 inches 11,56 mm
1 2 3 4 5
0° 0,490 0,502 0,490 0,507 0,497
90° 0,492 0,491 0,485 0,503 0,493
180° 0,455 0,463 0,464 0,465 0,476
270° 0,493 0,503 0,485 0,491 0,492
Inspector, Level II
Name: Napoleón Tamayo
Date: Signature:
Measured Thickness (inches)
2015-10-27
CLIENT: BEITE B&T CIA LTDA Order No. N.A.
ULTRASONIC INSPECTION B-SCANCS-2015- H-1110 REV 1
EXAMINATION REPORT
EXAMINATED ITEMS: SHELL Design thickness:
PLANTA GNL BAJO ALTO HEATER H-1110 Minimum measured thickness:
8/18/2019 7. Informe Inspección H- 1110 Rev1
6/6
Page 6 of 6
--- inches --- mm
0,612 inches 15,54 mm
1 2 3 4
0° 0,625 0,625 0,620 0,631
90° 0,626 0,630 0,627 0,627
180° 0,629 0,612 0,614 0,622
270° 0,667 0,632 0,630 0,626
Inspector, Level II
Name: Napoleón Tamayo
Date: Signature:
Measured Thickness (inches)
2015-10-27
CLIENT: BEITE B&T CIA LTDA Order No. N.A.
ULTRASONIC INSPECTION B-SCANCS-2015- H-1110 REV 1
EXAMINATION REPORT
EXAMINATED ITEMS: ELLIPTICAL HEAD (2) Design thickness:
PLANTA GNL BAJO ALTO HEATER H-1110 Minimum measured thickness: