INSPECCION DE PINTURAS EN CAMPO
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
CALIDAD EN PINTURAS INDUSTRIALES
NORMAS Y EQUIPOS
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 341
Distributed by
Criterios Generales
bull Contenido
bull Programa de trabajo
bull
Reunioacuten prejobbull Control de calidad
bull Materiales abrasivos
bull Medicioacuten de es esores
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Pruebas de adherencia por cinta
bull Perfil de anclaje
bull Condiciones ambientales
bull Pruebas de adherencia por traccioacuten mecaacutenica
bull Deteccioacuten de discontinuidades
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 441
Distributed by
Criterios Generales
REUNION PREJOB QUIENES INTERVIENEN
bull Especificador Persona oacute entidad que disentildea la especificacioacuten
bull Cliente Duentildeo del requerimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Contratista Firma ejecutora del proceso de la especificacioacutenDebe tener supropio departamento de Control de Calidad
bull Proveedor del recubrimiento Suministra el producto y asesoriacutea de manejoNunca reemplaza la interventoria
bull Inspector Documenta observa reporta de acuerdo con lo especificado
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 541
Distributed by
REUNION PREJOB
Tiene por objetivo analizar la especificacioacuten en cada una de suspartes para aclarar cualquier duda y dejar por escrito todos losalcances de los participantes asiacute como cualquier cambio que se
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
neces e
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 641
Distributed by
MATERIALES ABRASIVOS
bull Libre de contaminantes ( 2 MAX DE fe2o3)
bull Ph neutro
bull Minimo 6 en escala de mohs
bull Libre material organico
Pinturas para Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
TAMANtildeO(NORMA ASTM D-75)
bull Ret malla 8 1 max
bull Malla 8 - 20 20 - 40 max
bull Malla 20- 40 47- 80 maxbull Malla 40- 50 12 max
bull Pasa malla 50 2 max
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 741
Distributed by
Pinturas para Mantenimiento
PERFIL DE ANCLAJE (MILS) TIPO DE ABRASIVO NOTAS
05 80120 ARENA 90 PSI
1 3060 ARENA
15 2050 ARENA
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
2 1640 ARENA
25 1230 ARENA
3 820 ARENA
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 841
Distributed by
MEDICION DE ESPESOR HUMEDO
Consiste en medir la capa humeda de pintura recien aplicadapara realizar un seguimiento a los espesores que se estanmanejando
Pinturas para Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
Se puede calcular el espesor seco aproximado partiendo delespesor humedo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 941
Distributed by
SALES SOLUBLES
CLORUROS NITRATOS SULFATOS
microgcm2
microgcm2
microgcm2
Oil Company Tuberiacuteas 1 - -
NY State DOT Puentes 5 7 10Bridgecoat
Coatings Puentes 7 10 17
Inmersioacuten 5 - -
ENTIDAD SERVICIO
Shell Global US
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
mos r ca - -
Inmersioacuten 3 - -
Atmosfeacuterica 5 - -
EXXON Mobil 10 - -
Arizona Water Inmersioacuten 3 - -
(tanque agua) Atmosfeacuterica 5 - -
Inmersioacuten 3 - -
Atmosfeacuterica 5 -
Ecopetrol Todos 7 - 17
NAVSEA
Promigas SA
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1041
Distributed by
PREPARACION DE SUPERFICIE
PREPARACION DE SUPERFICIE
SE UTILIZAN CRITERIOS DE COMPARACION VISUAL
DEPENDE DEL ESTADO INICIAL DE LA LAMINA QUE SE HATRATADO Y DE LA PREPARACION DE SUPERFICIE UTILIZADA
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
GRADO COMERCIAL
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1141
Distributed by
PREPARACION DE SUPERFICIE
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1241
Distributed by
Pinturas para Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1341
Distributed by
MEDICION DE ESPESORES
bull Norma ldquosspc paint aplication specification ndeg 2Measurement of dry specification n 2rdquo
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
bull Procedimiento
bull Numero de mediciones
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1441
Distributed by
MEDICION DE ESPESORES
bull Calibracioacutenbull Debe ser calibrado anualmente en un laboratorio
autorizado
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Se debe calibrar antes de iniciar la medicionescon la laminilla mas cercana a los espesoresesperados
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1541
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1641
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1741
Distributed by
MEDICION DE ESPESORES
bull Procedimiento
bull Realizar 3 mediciones en un areacutea inferior a 1
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Promediar estos 3 datos hay que tener encuenta que ninguna medicioacuten debe ser inferior
al 80 del espesor especificado
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1841
Distributed by
NUMERO DE MEDICIONES
bull
Si el aacuterea es menor a 92 m2 tomar 5 muestreos
bull Si el aacuterea esta entre 92 m2 y 276 m2 medir cada 92 m2de acuerdo al numeral anterior
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Areas hasta 92 m2 escoger tres zonas de acuerdo alprimer numeral
bull Si es mayor a 92 m2 los primeros 92 m2 como el numeralanterior por cada 92 m2 tomar seguacuten el primer numeral
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1941
Distributed by
PRUEBAS DE ADHERENCIA POR CINTA
bullldquoEstandar test methodos for measuring adhesion bytape testrdquo norma astm d 3359
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
el contratista
bull En sistemas multicapas esta prueba generalmente
no muestra la adhesioacuten sobre el sustrato
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2041
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2141
Distributed by
PARA ESPESORES ENTRE 0 Y 2 MILS
bull Realizar una cuadricula de 25 partes a 1 mm dedistancia
bull A licar la cinta de arla entre 1 2 minutos
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull Calificar de acuerdo a los cuadros despegados 0b si sedespego mas del 65 hsta 5b que equivale a uncomportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2241
Distributed by
PARA ESPESORES ENTRE 2 Y 5 MILS
bull
Realizar una cuadricula de 25 partes a 2 mm dedistancia
bull
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull
Calificar de acuerdo a los cuadros despegados 0b si sedespego mas del 65 hsta 5b que equivale a uncomportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2341
Distributed by
PARA ESPESORES MAYORES A 5 MILS
bull
Realizar un corte en x con un angulo entre 30 y 45grados
bull
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull
Calificar de acuerdo a los cuadros despegados 0a si sedespego el cuadrado correspondiente a la x hasta 5aque equivale a un comportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2441
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2541
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Se realiza mediante la aplicacioacuten unos probadores o
Pinturas de Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
especiales y midiendo la tensioacuten aplicada paradespegar los mismos
bull Es una prueba de acuerdo con el cliente y el aplicador
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2641
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
de la pelicula como la cantidad de recubrimientosdespegados en el dado
bull La presion de ruptura esta de acuerdo a lossistemas aplicados y a la preparacioacuten de superficie
hecha
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2741
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull Procedimiento seguacuten norma astm d4541
bull Criterios(Seguacuten norma ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull a preparac on e super c e es a gra o comerc a yla pintura es base amida la tension minima es 710 psi
bull Si la preparacion de superficie es a grado comercial yla pintura es base amina la tension minima es 400 psi
bull
Si es poliuretano sobre pinturas aminas o amidas latension minima es 280 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2841
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios(Seguacuten norma icontec ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Si la preparacion es manual-mecanica la medicioncalificara indirectamente la calidad de la preparacion desuperficie
bull Si la pintura es un esmalte alquidico se debe esperar 15dias y la presion minima debe ser 250 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2941
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3041
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3141
Distributed by
PERFIL DE ANCLAJE
bull
Es la distancia promedio entre los picos y losvalles generados por la preparacion desuperficie
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Es una prueba de acuerdo cliente-aplicador
bull Se recomienda entre el 10 y el 15 del
espesor del sistema que se va a aplicar
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3241
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3341
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3441
Distributed by
PERFIL DE ANCLAJE
bull Se mide copiando el perfil mediante plaacutesticosespeciales y llevaacutendolo a un microacutemetro
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3541
Distributed by
CONDICIONES AMBIENTALES
bull Norma astm e337
bull Temperatura de chapabull Debe ser superior minimo en 3degc a la temperatura decrocio
bull Tem eratura ambiental
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
La reaccion de una pintura epoxica se detiene a menos de4degc
bull Humedad relativa
bull Se mide mediante higrometros ninguna pintura epoxica o
base solvente debe ser aplicada si la humedad relativa essuperior al 85
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3641
Distributed by
DETECCION DE DISCONTINUIDADES
bull Norma astm d 5162-91
bull Detectores bajo voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la pelicula mediantela circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se usa generalmente un detector entre 6 y 50 voltiosde corriente directa
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3741
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3841
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm d 5162-91
bull Detectores de alto voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se utilizan entre 1500 vol y 25000 vol
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3941
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm g 62-87
bull Detectores de alto voltaje para tuberias
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull
Se utilizan entre 1500 vol y 25000 volbull Los valores de prueba dependen de los
espesores del recubrimiento
Di t ib t d b
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4041
Distributed by
CONCLUSION
Para lograr un perfecto desempentildeo de unrecubrimiento debemos cubrir todas las fases delproceso de aplicacioacuten y seleccioacuten de forma integralEsto solo se lo ra con el total conocimiento or arte
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
de los involucrados de las teacutecnicas y caracteriacutesticasde los productos que usamos
Distributed by
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4141
Distributed by
Pinturas para mantenimiento
GRACIAS
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 241
Distributed by
INSPECCION DE PINTURAS EN CAMPO
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
CALIDAD EN PINTURAS INDUSTRIALES
NORMAS Y EQUIPOS
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 341
Distributed by
Criterios Generales
bull Contenido
bull Programa de trabajo
bull
Reunioacuten prejobbull Control de calidad
bull Materiales abrasivos
bull Medicioacuten de es esores
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Pruebas de adherencia por cinta
bull Perfil de anclaje
bull Condiciones ambientales
bull Pruebas de adherencia por traccioacuten mecaacutenica
bull Deteccioacuten de discontinuidades
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 441
Distributed by
Criterios Generales
REUNION PREJOB QUIENES INTERVIENEN
bull Especificador Persona oacute entidad que disentildea la especificacioacuten
bull Cliente Duentildeo del requerimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Contratista Firma ejecutora del proceso de la especificacioacutenDebe tener supropio departamento de Control de Calidad
bull Proveedor del recubrimiento Suministra el producto y asesoriacutea de manejoNunca reemplaza la interventoria
bull Inspector Documenta observa reporta de acuerdo con lo especificado
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 541
Distributed by
REUNION PREJOB
Tiene por objetivo analizar la especificacioacuten en cada una de suspartes para aclarar cualquier duda y dejar por escrito todos losalcances de los participantes asiacute como cualquier cambio que se
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
neces e
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 641
Distributed by
MATERIALES ABRASIVOS
bull Libre de contaminantes ( 2 MAX DE fe2o3)
bull Ph neutro
bull Minimo 6 en escala de mohs
bull Libre material organico
Pinturas para Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
TAMANtildeO(NORMA ASTM D-75)
bull Ret malla 8 1 max
bull Malla 8 - 20 20 - 40 max
bull Malla 20- 40 47- 80 maxbull Malla 40- 50 12 max
bull Pasa malla 50 2 max
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 741
Distributed by
Pinturas para Mantenimiento
PERFIL DE ANCLAJE (MILS) TIPO DE ABRASIVO NOTAS
05 80120 ARENA 90 PSI
1 3060 ARENA
15 2050 ARENA
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
2 1640 ARENA
25 1230 ARENA
3 820 ARENA
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 841
Distributed by
MEDICION DE ESPESOR HUMEDO
Consiste en medir la capa humeda de pintura recien aplicadapara realizar un seguimiento a los espesores que se estanmanejando
Pinturas para Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
Se puede calcular el espesor seco aproximado partiendo delespesor humedo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 941
Distributed by
SALES SOLUBLES
CLORUROS NITRATOS SULFATOS
microgcm2
microgcm2
microgcm2
Oil Company Tuberiacuteas 1 - -
NY State DOT Puentes 5 7 10Bridgecoat
Coatings Puentes 7 10 17
Inmersioacuten 5 - -
ENTIDAD SERVICIO
Shell Global US
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
mos r ca - -
Inmersioacuten 3 - -
Atmosfeacuterica 5 - -
EXXON Mobil 10 - -
Arizona Water Inmersioacuten 3 - -
(tanque agua) Atmosfeacuterica 5 - -
Inmersioacuten 3 - -
Atmosfeacuterica 5 -
Ecopetrol Todos 7 - 17
NAVSEA
Promigas SA
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1041
Distributed by
PREPARACION DE SUPERFICIE
PREPARACION DE SUPERFICIE
SE UTILIZAN CRITERIOS DE COMPARACION VISUAL
DEPENDE DEL ESTADO INICIAL DE LA LAMINA QUE SE HATRATADO Y DE LA PREPARACION DE SUPERFICIE UTILIZADA
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
GRADO COMERCIAL
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1141
Distributed by
PREPARACION DE SUPERFICIE
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1241
Distributed by
Pinturas para Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1341
Distributed by
MEDICION DE ESPESORES
bull Norma ldquosspc paint aplication specification ndeg 2Measurement of dry specification n 2rdquo
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
bull Procedimiento
bull Numero de mediciones
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1441
Distributed by
MEDICION DE ESPESORES
bull Calibracioacutenbull Debe ser calibrado anualmente en un laboratorio
autorizado
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Se debe calibrar antes de iniciar la medicionescon la laminilla mas cercana a los espesoresesperados
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1541
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1641
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1741
Distributed by
MEDICION DE ESPESORES
bull Procedimiento
bull Realizar 3 mediciones en un areacutea inferior a 1
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Promediar estos 3 datos hay que tener encuenta que ninguna medicioacuten debe ser inferior
al 80 del espesor especificado
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1841
Distributed by
NUMERO DE MEDICIONES
bull
Si el aacuterea es menor a 92 m2 tomar 5 muestreos
bull Si el aacuterea esta entre 92 m2 y 276 m2 medir cada 92 m2de acuerdo al numeral anterior
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Areas hasta 92 m2 escoger tres zonas de acuerdo alprimer numeral
bull Si es mayor a 92 m2 los primeros 92 m2 como el numeralanterior por cada 92 m2 tomar seguacuten el primer numeral
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1941
Distributed by
PRUEBAS DE ADHERENCIA POR CINTA
bullldquoEstandar test methodos for measuring adhesion bytape testrdquo norma astm d 3359
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
el contratista
bull En sistemas multicapas esta prueba generalmente
no muestra la adhesioacuten sobre el sustrato
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2041
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2141
Distributed by
PARA ESPESORES ENTRE 0 Y 2 MILS
bull Realizar una cuadricula de 25 partes a 1 mm dedistancia
bull A licar la cinta de arla entre 1 2 minutos
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull Calificar de acuerdo a los cuadros despegados 0b si sedespego mas del 65 hsta 5b que equivale a uncomportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2241
Distributed by
PARA ESPESORES ENTRE 2 Y 5 MILS
bull
Realizar una cuadricula de 25 partes a 2 mm dedistancia
bull
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull
Calificar de acuerdo a los cuadros despegados 0b si sedespego mas del 65 hsta 5b que equivale a uncomportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2341
Distributed by
PARA ESPESORES MAYORES A 5 MILS
bull
Realizar un corte en x con un angulo entre 30 y 45grados
bull
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull
Calificar de acuerdo a los cuadros despegados 0a si sedespego el cuadrado correspondiente a la x hasta 5aque equivale a un comportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2441
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2541
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Se realiza mediante la aplicacioacuten unos probadores o
Pinturas de Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
especiales y midiendo la tensioacuten aplicada paradespegar los mismos
bull Es una prueba de acuerdo con el cliente y el aplicador
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2641
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
de la pelicula como la cantidad de recubrimientosdespegados en el dado
bull La presion de ruptura esta de acuerdo a lossistemas aplicados y a la preparacioacuten de superficie
hecha
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2741
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull Procedimiento seguacuten norma astm d4541
bull Criterios(Seguacuten norma ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull a preparac on e super c e es a gra o comerc a yla pintura es base amida la tension minima es 710 psi
bull Si la preparacion de superficie es a grado comercial yla pintura es base amina la tension minima es 400 psi
bull
Si es poliuretano sobre pinturas aminas o amidas latension minima es 280 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2841
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios(Seguacuten norma icontec ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Si la preparacion es manual-mecanica la medicioncalificara indirectamente la calidad de la preparacion desuperficie
bull Si la pintura es un esmalte alquidico se debe esperar 15dias y la presion minima debe ser 250 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2941
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3041
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3141
Distributed by
PERFIL DE ANCLAJE
bull
Es la distancia promedio entre los picos y losvalles generados por la preparacion desuperficie
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Es una prueba de acuerdo cliente-aplicador
bull Se recomienda entre el 10 y el 15 del
espesor del sistema que se va a aplicar
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3241
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3341
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3441
Distributed by
PERFIL DE ANCLAJE
bull Se mide copiando el perfil mediante plaacutesticosespeciales y llevaacutendolo a un microacutemetro
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3541
Distributed by
CONDICIONES AMBIENTALES
bull Norma astm e337
bull Temperatura de chapabull Debe ser superior minimo en 3degc a la temperatura decrocio
bull Tem eratura ambiental
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
La reaccion de una pintura epoxica se detiene a menos de4degc
bull Humedad relativa
bull Se mide mediante higrometros ninguna pintura epoxica o
base solvente debe ser aplicada si la humedad relativa essuperior al 85
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3641
Distributed by
DETECCION DE DISCONTINUIDADES
bull Norma astm d 5162-91
bull Detectores bajo voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la pelicula mediantela circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se usa generalmente un detector entre 6 y 50 voltiosde corriente directa
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3741
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3841
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm d 5162-91
bull Detectores de alto voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se utilizan entre 1500 vol y 25000 vol
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3941
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm g 62-87
bull Detectores de alto voltaje para tuberias
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull
Se utilizan entre 1500 vol y 25000 volbull Los valores de prueba dependen de los
espesores del recubrimiento
Di t ib t d b
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4041
Distributed by
CONCLUSION
Para lograr un perfecto desempentildeo de unrecubrimiento debemos cubrir todas las fases delproceso de aplicacioacuten y seleccioacuten de forma integralEsto solo se lo ra con el total conocimiento or arte
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
de los involucrados de las teacutecnicas y caracteriacutesticasde los productos que usamos
Distributed by
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4141
Distributed by
Pinturas para mantenimiento
GRACIAS
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 341
Distributed by
Criterios Generales
bull Contenido
bull Programa de trabajo
bull
Reunioacuten prejobbull Control de calidad
bull Materiales abrasivos
bull Medicioacuten de es esores
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Pruebas de adherencia por cinta
bull Perfil de anclaje
bull Condiciones ambientales
bull Pruebas de adherencia por traccioacuten mecaacutenica
bull Deteccioacuten de discontinuidades
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 441
Distributed by
Criterios Generales
REUNION PREJOB QUIENES INTERVIENEN
bull Especificador Persona oacute entidad que disentildea la especificacioacuten
bull Cliente Duentildeo del requerimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Contratista Firma ejecutora del proceso de la especificacioacutenDebe tener supropio departamento de Control de Calidad
bull Proveedor del recubrimiento Suministra el producto y asesoriacutea de manejoNunca reemplaza la interventoria
bull Inspector Documenta observa reporta de acuerdo con lo especificado
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 541
Distributed by
REUNION PREJOB
Tiene por objetivo analizar la especificacioacuten en cada una de suspartes para aclarar cualquier duda y dejar por escrito todos losalcances de los participantes asiacute como cualquier cambio que se
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
neces e
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 641
Distributed by
MATERIALES ABRASIVOS
bull Libre de contaminantes ( 2 MAX DE fe2o3)
bull Ph neutro
bull Minimo 6 en escala de mohs
bull Libre material organico
Pinturas para Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
TAMANtildeO(NORMA ASTM D-75)
bull Ret malla 8 1 max
bull Malla 8 - 20 20 - 40 max
bull Malla 20- 40 47- 80 maxbull Malla 40- 50 12 max
bull Pasa malla 50 2 max
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 741
Distributed by
Pinturas para Mantenimiento
PERFIL DE ANCLAJE (MILS) TIPO DE ABRASIVO NOTAS
05 80120 ARENA 90 PSI
1 3060 ARENA
15 2050 ARENA
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
2 1640 ARENA
25 1230 ARENA
3 820 ARENA
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 841
Distributed by
MEDICION DE ESPESOR HUMEDO
Consiste en medir la capa humeda de pintura recien aplicadapara realizar un seguimiento a los espesores que se estanmanejando
Pinturas para Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
Se puede calcular el espesor seco aproximado partiendo delespesor humedo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 941
Distributed by
SALES SOLUBLES
CLORUROS NITRATOS SULFATOS
microgcm2
microgcm2
microgcm2
Oil Company Tuberiacuteas 1 - -
NY State DOT Puentes 5 7 10Bridgecoat
Coatings Puentes 7 10 17
Inmersioacuten 5 - -
ENTIDAD SERVICIO
Shell Global US
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
mos r ca - -
Inmersioacuten 3 - -
Atmosfeacuterica 5 - -
EXXON Mobil 10 - -
Arizona Water Inmersioacuten 3 - -
(tanque agua) Atmosfeacuterica 5 - -
Inmersioacuten 3 - -
Atmosfeacuterica 5 -
Ecopetrol Todos 7 - 17
NAVSEA
Promigas SA
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1041
Distributed by
PREPARACION DE SUPERFICIE
PREPARACION DE SUPERFICIE
SE UTILIZAN CRITERIOS DE COMPARACION VISUAL
DEPENDE DEL ESTADO INICIAL DE LA LAMINA QUE SE HATRATADO Y DE LA PREPARACION DE SUPERFICIE UTILIZADA
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
GRADO COMERCIAL
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1141
Distributed by
PREPARACION DE SUPERFICIE
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1241
Distributed by
Pinturas para Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1341
Distributed by
MEDICION DE ESPESORES
bull Norma ldquosspc paint aplication specification ndeg 2Measurement of dry specification n 2rdquo
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
bull Procedimiento
bull Numero de mediciones
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1441
Distributed by
MEDICION DE ESPESORES
bull Calibracioacutenbull Debe ser calibrado anualmente en un laboratorio
autorizado
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Se debe calibrar antes de iniciar la medicionescon la laminilla mas cercana a los espesoresesperados
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1541
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1641
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1741
Distributed by
MEDICION DE ESPESORES
bull Procedimiento
bull Realizar 3 mediciones en un areacutea inferior a 1
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Promediar estos 3 datos hay que tener encuenta que ninguna medicioacuten debe ser inferior
al 80 del espesor especificado
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1841
Distributed by
NUMERO DE MEDICIONES
bull
Si el aacuterea es menor a 92 m2 tomar 5 muestreos
bull Si el aacuterea esta entre 92 m2 y 276 m2 medir cada 92 m2de acuerdo al numeral anterior
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Areas hasta 92 m2 escoger tres zonas de acuerdo alprimer numeral
bull Si es mayor a 92 m2 los primeros 92 m2 como el numeralanterior por cada 92 m2 tomar seguacuten el primer numeral
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1941
Distributed by
PRUEBAS DE ADHERENCIA POR CINTA
bullldquoEstandar test methodos for measuring adhesion bytape testrdquo norma astm d 3359
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
el contratista
bull En sistemas multicapas esta prueba generalmente
no muestra la adhesioacuten sobre el sustrato
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2041
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2141
Distributed by
PARA ESPESORES ENTRE 0 Y 2 MILS
bull Realizar una cuadricula de 25 partes a 1 mm dedistancia
bull A licar la cinta de arla entre 1 2 minutos
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull Calificar de acuerdo a los cuadros despegados 0b si sedespego mas del 65 hsta 5b que equivale a uncomportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2241
Distributed by
PARA ESPESORES ENTRE 2 Y 5 MILS
bull
Realizar una cuadricula de 25 partes a 2 mm dedistancia
bull
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull
Calificar de acuerdo a los cuadros despegados 0b si sedespego mas del 65 hsta 5b que equivale a uncomportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2341
Distributed by
PARA ESPESORES MAYORES A 5 MILS
bull
Realizar un corte en x con un angulo entre 30 y 45grados
bull
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull
Calificar de acuerdo a los cuadros despegados 0a si sedespego el cuadrado correspondiente a la x hasta 5aque equivale a un comportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2441
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2541
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Se realiza mediante la aplicacioacuten unos probadores o
Pinturas de Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
especiales y midiendo la tensioacuten aplicada paradespegar los mismos
bull Es una prueba de acuerdo con el cliente y el aplicador
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2641
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
de la pelicula como la cantidad de recubrimientosdespegados en el dado
bull La presion de ruptura esta de acuerdo a lossistemas aplicados y a la preparacioacuten de superficie
hecha
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2741
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull Procedimiento seguacuten norma astm d4541
bull Criterios(Seguacuten norma ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull a preparac on e super c e es a gra o comerc a yla pintura es base amida la tension minima es 710 psi
bull Si la preparacion de superficie es a grado comercial yla pintura es base amina la tension minima es 400 psi
bull
Si es poliuretano sobre pinturas aminas o amidas latension minima es 280 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2841
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios(Seguacuten norma icontec ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Si la preparacion es manual-mecanica la medicioncalificara indirectamente la calidad de la preparacion desuperficie
bull Si la pintura es un esmalte alquidico se debe esperar 15dias y la presion minima debe ser 250 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2941
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3041
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3141
Distributed by
PERFIL DE ANCLAJE
bull
Es la distancia promedio entre los picos y losvalles generados por la preparacion desuperficie
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Es una prueba de acuerdo cliente-aplicador
bull Se recomienda entre el 10 y el 15 del
espesor del sistema que se va a aplicar
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3241
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3341
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3441
Distributed by
PERFIL DE ANCLAJE
bull Se mide copiando el perfil mediante plaacutesticosespeciales y llevaacutendolo a un microacutemetro
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3541
Distributed by
CONDICIONES AMBIENTALES
bull Norma astm e337
bull Temperatura de chapabull Debe ser superior minimo en 3degc a la temperatura decrocio
bull Tem eratura ambiental
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
La reaccion de una pintura epoxica se detiene a menos de4degc
bull Humedad relativa
bull Se mide mediante higrometros ninguna pintura epoxica o
base solvente debe ser aplicada si la humedad relativa essuperior al 85
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3641
Distributed by
DETECCION DE DISCONTINUIDADES
bull Norma astm d 5162-91
bull Detectores bajo voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la pelicula mediantela circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se usa generalmente un detector entre 6 y 50 voltiosde corriente directa
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3741
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3841
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm d 5162-91
bull Detectores de alto voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se utilizan entre 1500 vol y 25000 vol
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3941
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm g 62-87
bull Detectores de alto voltaje para tuberias
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull
Se utilizan entre 1500 vol y 25000 volbull Los valores de prueba dependen de los
espesores del recubrimiento
Di t ib t d b
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4041
Distributed by
CONCLUSION
Para lograr un perfecto desempentildeo de unrecubrimiento debemos cubrir todas las fases delproceso de aplicacioacuten y seleccioacuten de forma integralEsto solo se lo ra con el total conocimiento or arte
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
de los involucrados de las teacutecnicas y caracteriacutesticasde los productos que usamos
Distributed by
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4141
Distributed by
Pinturas para mantenimiento
GRACIAS
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 441
Distributed by
Criterios Generales
REUNION PREJOB QUIENES INTERVIENEN
bull Especificador Persona oacute entidad que disentildea la especificacioacuten
bull Cliente Duentildeo del requerimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Contratista Firma ejecutora del proceso de la especificacioacutenDebe tener supropio departamento de Control de Calidad
bull Proveedor del recubrimiento Suministra el producto y asesoriacutea de manejoNunca reemplaza la interventoria
bull Inspector Documenta observa reporta de acuerdo con lo especificado
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 541
Distributed by
REUNION PREJOB
Tiene por objetivo analizar la especificacioacuten en cada una de suspartes para aclarar cualquier duda y dejar por escrito todos losalcances de los participantes asiacute como cualquier cambio que se
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
neces e
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 641
Distributed by
MATERIALES ABRASIVOS
bull Libre de contaminantes ( 2 MAX DE fe2o3)
bull Ph neutro
bull Minimo 6 en escala de mohs
bull Libre material organico
Pinturas para Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
TAMANtildeO(NORMA ASTM D-75)
bull Ret malla 8 1 max
bull Malla 8 - 20 20 - 40 max
bull Malla 20- 40 47- 80 maxbull Malla 40- 50 12 max
bull Pasa malla 50 2 max
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 741
Distributed by
Pinturas para Mantenimiento
PERFIL DE ANCLAJE (MILS) TIPO DE ABRASIVO NOTAS
05 80120 ARENA 90 PSI
1 3060 ARENA
15 2050 ARENA
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
2 1640 ARENA
25 1230 ARENA
3 820 ARENA
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 841
Distributed by
MEDICION DE ESPESOR HUMEDO
Consiste en medir la capa humeda de pintura recien aplicadapara realizar un seguimiento a los espesores que se estanmanejando
Pinturas para Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
Se puede calcular el espesor seco aproximado partiendo delespesor humedo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 941
Distributed by
SALES SOLUBLES
CLORUROS NITRATOS SULFATOS
microgcm2
microgcm2
microgcm2
Oil Company Tuberiacuteas 1 - -
NY State DOT Puentes 5 7 10Bridgecoat
Coatings Puentes 7 10 17
Inmersioacuten 5 - -
ENTIDAD SERVICIO
Shell Global US
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
mos r ca - -
Inmersioacuten 3 - -
Atmosfeacuterica 5 - -
EXXON Mobil 10 - -
Arizona Water Inmersioacuten 3 - -
(tanque agua) Atmosfeacuterica 5 - -
Inmersioacuten 3 - -
Atmosfeacuterica 5 -
Ecopetrol Todos 7 - 17
NAVSEA
Promigas SA
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1041
Distributed by
PREPARACION DE SUPERFICIE
PREPARACION DE SUPERFICIE
SE UTILIZAN CRITERIOS DE COMPARACION VISUAL
DEPENDE DEL ESTADO INICIAL DE LA LAMINA QUE SE HATRATADO Y DE LA PREPARACION DE SUPERFICIE UTILIZADA
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
GRADO COMERCIAL
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1141
Distributed by
PREPARACION DE SUPERFICIE
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1241
Distributed by
Pinturas para Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1341
Distributed by
MEDICION DE ESPESORES
bull Norma ldquosspc paint aplication specification ndeg 2Measurement of dry specification n 2rdquo
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
bull Procedimiento
bull Numero de mediciones
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1441
Distributed by
MEDICION DE ESPESORES
bull Calibracioacutenbull Debe ser calibrado anualmente en un laboratorio
autorizado
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Se debe calibrar antes de iniciar la medicionescon la laminilla mas cercana a los espesoresesperados
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1541
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1641
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1741
Distributed by
MEDICION DE ESPESORES
bull Procedimiento
bull Realizar 3 mediciones en un areacutea inferior a 1
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Promediar estos 3 datos hay que tener encuenta que ninguna medicioacuten debe ser inferior
al 80 del espesor especificado
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1841
Distributed by
NUMERO DE MEDICIONES
bull
Si el aacuterea es menor a 92 m2 tomar 5 muestreos
bull Si el aacuterea esta entre 92 m2 y 276 m2 medir cada 92 m2de acuerdo al numeral anterior
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Areas hasta 92 m2 escoger tres zonas de acuerdo alprimer numeral
bull Si es mayor a 92 m2 los primeros 92 m2 como el numeralanterior por cada 92 m2 tomar seguacuten el primer numeral
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1941
Distributed by
PRUEBAS DE ADHERENCIA POR CINTA
bullldquoEstandar test methodos for measuring adhesion bytape testrdquo norma astm d 3359
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
el contratista
bull En sistemas multicapas esta prueba generalmente
no muestra la adhesioacuten sobre el sustrato
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2041
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2141
Distributed by
PARA ESPESORES ENTRE 0 Y 2 MILS
bull Realizar una cuadricula de 25 partes a 1 mm dedistancia
bull A licar la cinta de arla entre 1 2 minutos
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull Calificar de acuerdo a los cuadros despegados 0b si sedespego mas del 65 hsta 5b que equivale a uncomportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2241
Distributed by
PARA ESPESORES ENTRE 2 Y 5 MILS
bull
Realizar una cuadricula de 25 partes a 2 mm dedistancia
bull
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull
Calificar de acuerdo a los cuadros despegados 0b si sedespego mas del 65 hsta 5b que equivale a uncomportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2341
Distributed by
PARA ESPESORES MAYORES A 5 MILS
bull
Realizar un corte en x con un angulo entre 30 y 45grados
bull
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull
Calificar de acuerdo a los cuadros despegados 0a si sedespego el cuadrado correspondiente a la x hasta 5aque equivale a un comportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2441
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2541
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Se realiza mediante la aplicacioacuten unos probadores o
Pinturas de Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
especiales y midiendo la tensioacuten aplicada paradespegar los mismos
bull Es una prueba de acuerdo con el cliente y el aplicador
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2641
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
de la pelicula como la cantidad de recubrimientosdespegados en el dado
bull La presion de ruptura esta de acuerdo a lossistemas aplicados y a la preparacioacuten de superficie
hecha
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2741
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull Procedimiento seguacuten norma astm d4541
bull Criterios(Seguacuten norma ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull a preparac on e super c e es a gra o comerc a yla pintura es base amida la tension minima es 710 psi
bull Si la preparacion de superficie es a grado comercial yla pintura es base amina la tension minima es 400 psi
bull
Si es poliuretano sobre pinturas aminas o amidas latension minima es 280 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2841
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios(Seguacuten norma icontec ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Si la preparacion es manual-mecanica la medicioncalificara indirectamente la calidad de la preparacion desuperficie
bull Si la pintura es un esmalte alquidico se debe esperar 15dias y la presion minima debe ser 250 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2941
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3041
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3141
Distributed by
PERFIL DE ANCLAJE
bull
Es la distancia promedio entre los picos y losvalles generados por la preparacion desuperficie
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Es una prueba de acuerdo cliente-aplicador
bull Se recomienda entre el 10 y el 15 del
espesor del sistema que se va a aplicar
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3241
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3341
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3441
Distributed by
PERFIL DE ANCLAJE
bull Se mide copiando el perfil mediante plaacutesticosespeciales y llevaacutendolo a un microacutemetro
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3541
Distributed by
CONDICIONES AMBIENTALES
bull Norma astm e337
bull Temperatura de chapabull Debe ser superior minimo en 3degc a la temperatura decrocio
bull Tem eratura ambiental
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
La reaccion de una pintura epoxica se detiene a menos de4degc
bull Humedad relativa
bull Se mide mediante higrometros ninguna pintura epoxica o
base solvente debe ser aplicada si la humedad relativa essuperior al 85
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3641
Distributed by
DETECCION DE DISCONTINUIDADES
bull Norma astm d 5162-91
bull Detectores bajo voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la pelicula mediantela circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se usa generalmente un detector entre 6 y 50 voltiosde corriente directa
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3741
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3841
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm d 5162-91
bull Detectores de alto voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se utilizan entre 1500 vol y 25000 vol
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3941
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm g 62-87
bull Detectores de alto voltaje para tuberias
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull
Se utilizan entre 1500 vol y 25000 volbull Los valores de prueba dependen de los
espesores del recubrimiento
Di t ib t d b
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4041
Distributed by
CONCLUSION
Para lograr un perfecto desempentildeo de unrecubrimiento debemos cubrir todas las fases delproceso de aplicacioacuten y seleccioacuten de forma integralEsto solo se lo ra con el total conocimiento or arte
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
de los involucrados de las teacutecnicas y caracteriacutesticasde los productos que usamos
Distributed by
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4141
Distributed by
Pinturas para mantenimiento
GRACIAS
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 541
Distributed by
REUNION PREJOB
Tiene por objetivo analizar la especificacioacuten en cada una de suspartes para aclarar cualquier duda y dejar por escrito todos losalcances de los participantes asiacute como cualquier cambio que se
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
neces e
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 641
Distributed by
MATERIALES ABRASIVOS
bull Libre de contaminantes ( 2 MAX DE fe2o3)
bull Ph neutro
bull Minimo 6 en escala de mohs
bull Libre material organico
Pinturas para Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
TAMANtildeO(NORMA ASTM D-75)
bull Ret malla 8 1 max
bull Malla 8 - 20 20 - 40 max
bull Malla 20- 40 47- 80 maxbull Malla 40- 50 12 max
bull Pasa malla 50 2 max
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 741
Distributed by
Pinturas para Mantenimiento
PERFIL DE ANCLAJE (MILS) TIPO DE ABRASIVO NOTAS
05 80120 ARENA 90 PSI
1 3060 ARENA
15 2050 ARENA
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
2 1640 ARENA
25 1230 ARENA
3 820 ARENA
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 841
Distributed by
MEDICION DE ESPESOR HUMEDO
Consiste en medir la capa humeda de pintura recien aplicadapara realizar un seguimiento a los espesores que se estanmanejando
Pinturas para Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
Se puede calcular el espesor seco aproximado partiendo delespesor humedo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 941
Distributed by
SALES SOLUBLES
CLORUROS NITRATOS SULFATOS
microgcm2
microgcm2
microgcm2
Oil Company Tuberiacuteas 1 - -
NY State DOT Puentes 5 7 10Bridgecoat
Coatings Puentes 7 10 17
Inmersioacuten 5 - -
ENTIDAD SERVICIO
Shell Global US
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
mos r ca - -
Inmersioacuten 3 - -
Atmosfeacuterica 5 - -
EXXON Mobil 10 - -
Arizona Water Inmersioacuten 3 - -
(tanque agua) Atmosfeacuterica 5 - -
Inmersioacuten 3 - -
Atmosfeacuterica 5 -
Ecopetrol Todos 7 - 17
NAVSEA
Promigas SA
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1041
Distributed by
PREPARACION DE SUPERFICIE
PREPARACION DE SUPERFICIE
SE UTILIZAN CRITERIOS DE COMPARACION VISUAL
DEPENDE DEL ESTADO INICIAL DE LA LAMINA QUE SE HATRATADO Y DE LA PREPARACION DE SUPERFICIE UTILIZADA
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
GRADO COMERCIAL
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1141
Distributed by
PREPARACION DE SUPERFICIE
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1241
Distributed by
Pinturas para Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1341
Distributed by
MEDICION DE ESPESORES
bull Norma ldquosspc paint aplication specification ndeg 2Measurement of dry specification n 2rdquo
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
bull Procedimiento
bull Numero de mediciones
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1441
Distributed by
MEDICION DE ESPESORES
bull Calibracioacutenbull Debe ser calibrado anualmente en un laboratorio
autorizado
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Se debe calibrar antes de iniciar la medicionescon la laminilla mas cercana a los espesoresesperados
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1541
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1641
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1741
Distributed by
MEDICION DE ESPESORES
bull Procedimiento
bull Realizar 3 mediciones en un areacutea inferior a 1
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Promediar estos 3 datos hay que tener encuenta que ninguna medicioacuten debe ser inferior
al 80 del espesor especificado
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1841
Distributed by
NUMERO DE MEDICIONES
bull
Si el aacuterea es menor a 92 m2 tomar 5 muestreos
bull Si el aacuterea esta entre 92 m2 y 276 m2 medir cada 92 m2de acuerdo al numeral anterior
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Areas hasta 92 m2 escoger tres zonas de acuerdo alprimer numeral
bull Si es mayor a 92 m2 los primeros 92 m2 como el numeralanterior por cada 92 m2 tomar seguacuten el primer numeral
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1941
Distributed by
PRUEBAS DE ADHERENCIA POR CINTA
bullldquoEstandar test methodos for measuring adhesion bytape testrdquo norma astm d 3359
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
el contratista
bull En sistemas multicapas esta prueba generalmente
no muestra la adhesioacuten sobre el sustrato
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2041
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2141
Distributed by
PARA ESPESORES ENTRE 0 Y 2 MILS
bull Realizar una cuadricula de 25 partes a 1 mm dedistancia
bull A licar la cinta de arla entre 1 2 minutos
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull Calificar de acuerdo a los cuadros despegados 0b si sedespego mas del 65 hsta 5b que equivale a uncomportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2241
Distributed by
PARA ESPESORES ENTRE 2 Y 5 MILS
bull
Realizar una cuadricula de 25 partes a 2 mm dedistancia
bull
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull
Calificar de acuerdo a los cuadros despegados 0b si sedespego mas del 65 hsta 5b que equivale a uncomportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2341
Distributed by
PARA ESPESORES MAYORES A 5 MILS
bull
Realizar un corte en x con un angulo entre 30 y 45grados
bull
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull
Calificar de acuerdo a los cuadros despegados 0a si sedespego el cuadrado correspondiente a la x hasta 5aque equivale a un comportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2441
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2541
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Se realiza mediante la aplicacioacuten unos probadores o
Pinturas de Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
especiales y midiendo la tensioacuten aplicada paradespegar los mismos
bull Es una prueba de acuerdo con el cliente y el aplicador
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2641
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
de la pelicula como la cantidad de recubrimientosdespegados en el dado
bull La presion de ruptura esta de acuerdo a lossistemas aplicados y a la preparacioacuten de superficie
hecha
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2741
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull Procedimiento seguacuten norma astm d4541
bull Criterios(Seguacuten norma ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull a preparac on e super c e es a gra o comerc a yla pintura es base amida la tension minima es 710 psi
bull Si la preparacion de superficie es a grado comercial yla pintura es base amina la tension minima es 400 psi
bull
Si es poliuretano sobre pinturas aminas o amidas latension minima es 280 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2841
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios(Seguacuten norma icontec ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Si la preparacion es manual-mecanica la medicioncalificara indirectamente la calidad de la preparacion desuperficie
bull Si la pintura es un esmalte alquidico se debe esperar 15dias y la presion minima debe ser 250 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2941
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3041
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3141
Distributed by
PERFIL DE ANCLAJE
bull
Es la distancia promedio entre los picos y losvalles generados por la preparacion desuperficie
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Es una prueba de acuerdo cliente-aplicador
bull Se recomienda entre el 10 y el 15 del
espesor del sistema que se va a aplicar
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3241
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3341
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3441
Distributed by
PERFIL DE ANCLAJE
bull Se mide copiando el perfil mediante plaacutesticosespeciales y llevaacutendolo a un microacutemetro
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3541
Distributed by
CONDICIONES AMBIENTALES
bull Norma astm e337
bull Temperatura de chapabull Debe ser superior minimo en 3degc a la temperatura decrocio
bull Tem eratura ambiental
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
La reaccion de una pintura epoxica se detiene a menos de4degc
bull Humedad relativa
bull Se mide mediante higrometros ninguna pintura epoxica o
base solvente debe ser aplicada si la humedad relativa essuperior al 85
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3641
Distributed by
DETECCION DE DISCONTINUIDADES
bull Norma astm d 5162-91
bull Detectores bajo voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la pelicula mediantela circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se usa generalmente un detector entre 6 y 50 voltiosde corriente directa
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3741
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3841
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm d 5162-91
bull Detectores de alto voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se utilizan entre 1500 vol y 25000 vol
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3941
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm g 62-87
bull Detectores de alto voltaje para tuberias
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull
Se utilizan entre 1500 vol y 25000 volbull Los valores de prueba dependen de los
espesores del recubrimiento
Di t ib t d b
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4041
Distributed by
CONCLUSION
Para lograr un perfecto desempentildeo de unrecubrimiento debemos cubrir todas las fases delproceso de aplicacioacuten y seleccioacuten de forma integralEsto solo se lo ra con el total conocimiento or arte
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
de los involucrados de las teacutecnicas y caracteriacutesticasde los productos que usamos
Distributed by
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4141
Distributed by
Pinturas para mantenimiento
GRACIAS
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 641
Distributed by
MATERIALES ABRASIVOS
bull Libre de contaminantes ( 2 MAX DE fe2o3)
bull Ph neutro
bull Minimo 6 en escala de mohs
bull Libre material organico
Pinturas para Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
TAMANtildeO(NORMA ASTM D-75)
bull Ret malla 8 1 max
bull Malla 8 - 20 20 - 40 max
bull Malla 20- 40 47- 80 maxbull Malla 40- 50 12 max
bull Pasa malla 50 2 max
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 741
Distributed by
Pinturas para Mantenimiento
PERFIL DE ANCLAJE (MILS) TIPO DE ABRASIVO NOTAS
05 80120 ARENA 90 PSI
1 3060 ARENA
15 2050 ARENA
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
2 1640 ARENA
25 1230 ARENA
3 820 ARENA
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 841
Distributed by
MEDICION DE ESPESOR HUMEDO
Consiste en medir la capa humeda de pintura recien aplicadapara realizar un seguimiento a los espesores que se estanmanejando
Pinturas para Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
Se puede calcular el espesor seco aproximado partiendo delespesor humedo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 941
Distributed by
SALES SOLUBLES
CLORUROS NITRATOS SULFATOS
microgcm2
microgcm2
microgcm2
Oil Company Tuberiacuteas 1 - -
NY State DOT Puentes 5 7 10Bridgecoat
Coatings Puentes 7 10 17
Inmersioacuten 5 - -
ENTIDAD SERVICIO
Shell Global US
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
mos r ca - -
Inmersioacuten 3 - -
Atmosfeacuterica 5 - -
EXXON Mobil 10 - -
Arizona Water Inmersioacuten 3 - -
(tanque agua) Atmosfeacuterica 5 - -
Inmersioacuten 3 - -
Atmosfeacuterica 5 -
Ecopetrol Todos 7 - 17
NAVSEA
Promigas SA
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1041
Distributed by
PREPARACION DE SUPERFICIE
PREPARACION DE SUPERFICIE
SE UTILIZAN CRITERIOS DE COMPARACION VISUAL
DEPENDE DEL ESTADO INICIAL DE LA LAMINA QUE SE HATRATADO Y DE LA PREPARACION DE SUPERFICIE UTILIZADA
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
GRADO COMERCIAL
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1141
Distributed by
PREPARACION DE SUPERFICIE
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1241
Distributed by
Pinturas para Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1341
Distributed by
MEDICION DE ESPESORES
bull Norma ldquosspc paint aplication specification ndeg 2Measurement of dry specification n 2rdquo
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
bull Procedimiento
bull Numero de mediciones
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1441
Distributed by
MEDICION DE ESPESORES
bull Calibracioacutenbull Debe ser calibrado anualmente en un laboratorio
autorizado
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Se debe calibrar antes de iniciar la medicionescon la laminilla mas cercana a los espesoresesperados
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1541
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1641
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1741
Distributed by
MEDICION DE ESPESORES
bull Procedimiento
bull Realizar 3 mediciones en un areacutea inferior a 1
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Promediar estos 3 datos hay que tener encuenta que ninguna medicioacuten debe ser inferior
al 80 del espesor especificado
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1841
Distributed by
NUMERO DE MEDICIONES
bull
Si el aacuterea es menor a 92 m2 tomar 5 muestreos
bull Si el aacuterea esta entre 92 m2 y 276 m2 medir cada 92 m2de acuerdo al numeral anterior
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Areas hasta 92 m2 escoger tres zonas de acuerdo alprimer numeral
bull Si es mayor a 92 m2 los primeros 92 m2 como el numeralanterior por cada 92 m2 tomar seguacuten el primer numeral
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1941
Distributed by
PRUEBAS DE ADHERENCIA POR CINTA
bullldquoEstandar test methodos for measuring adhesion bytape testrdquo norma astm d 3359
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
el contratista
bull En sistemas multicapas esta prueba generalmente
no muestra la adhesioacuten sobre el sustrato
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2041
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2141
Distributed by
PARA ESPESORES ENTRE 0 Y 2 MILS
bull Realizar una cuadricula de 25 partes a 1 mm dedistancia
bull A licar la cinta de arla entre 1 2 minutos
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull Calificar de acuerdo a los cuadros despegados 0b si sedespego mas del 65 hsta 5b que equivale a uncomportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2241
Distributed by
PARA ESPESORES ENTRE 2 Y 5 MILS
bull
Realizar una cuadricula de 25 partes a 2 mm dedistancia
bull
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull
Calificar de acuerdo a los cuadros despegados 0b si sedespego mas del 65 hsta 5b que equivale a uncomportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2341
Distributed by
PARA ESPESORES MAYORES A 5 MILS
bull
Realizar un corte en x con un angulo entre 30 y 45grados
bull
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull
Calificar de acuerdo a los cuadros despegados 0a si sedespego el cuadrado correspondiente a la x hasta 5aque equivale a un comportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2441
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2541
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Se realiza mediante la aplicacioacuten unos probadores o
Pinturas de Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
especiales y midiendo la tensioacuten aplicada paradespegar los mismos
bull Es una prueba de acuerdo con el cliente y el aplicador
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2641
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
de la pelicula como la cantidad de recubrimientosdespegados en el dado
bull La presion de ruptura esta de acuerdo a lossistemas aplicados y a la preparacioacuten de superficie
hecha
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2741
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull Procedimiento seguacuten norma astm d4541
bull Criterios(Seguacuten norma ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull a preparac on e super c e es a gra o comerc a yla pintura es base amida la tension minima es 710 psi
bull Si la preparacion de superficie es a grado comercial yla pintura es base amina la tension minima es 400 psi
bull
Si es poliuretano sobre pinturas aminas o amidas latension minima es 280 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2841
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios(Seguacuten norma icontec ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Si la preparacion es manual-mecanica la medicioncalificara indirectamente la calidad de la preparacion desuperficie
bull Si la pintura es un esmalte alquidico se debe esperar 15dias y la presion minima debe ser 250 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2941
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3041
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3141
Distributed by
PERFIL DE ANCLAJE
bull
Es la distancia promedio entre los picos y losvalles generados por la preparacion desuperficie
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Es una prueba de acuerdo cliente-aplicador
bull Se recomienda entre el 10 y el 15 del
espesor del sistema que se va a aplicar
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3241
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3341
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3441
Distributed by
PERFIL DE ANCLAJE
bull Se mide copiando el perfil mediante plaacutesticosespeciales y llevaacutendolo a un microacutemetro
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3541
Distributed by
CONDICIONES AMBIENTALES
bull Norma astm e337
bull Temperatura de chapabull Debe ser superior minimo en 3degc a la temperatura decrocio
bull Tem eratura ambiental
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
La reaccion de una pintura epoxica se detiene a menos de4degc
bull Humedad relativa
bull Se mide mediante higrometros ninguna pintura epoxica o
base solvente debe ser aplicada si la humedad relativa essuperior al 85
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3641
Distributed by
DETECCION DE DISCONTINUIDADES
bull Norma astm d 5162-91
bull Detectores bajo voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la pelicula mediantela circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se usa generalmente un detector entre 6 y 50 voltiosde corriente directa
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3741
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3841
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm d 5162-91
bull Detectores de alto voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se utilizan entre 1500 vol y 25000 vol
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3941
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm g 62-87
bull Detectores de alto voltaje para tuberias
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull
Se utilizan entre 1500 vol y 25000 volbull Los valores de prueba dependen de los
espesores del recubrimiento
Di t ib t d b
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4041
Distributed by
CONCLUSION
Para lograr un perfecto desempentildeo de unrecubrimiento debemos cubrir todas las fases delproceso de aplicacioacuten y seleccioacuten de forma integralEsto solo se lo ra con el total conocimiento or arte
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
de los involucrados de las teacutecnicas y caracteriacutesticasde los productos que usamos
Distributed by
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4141
Distributed by
Pinturas para mantenimiento
GRACIAS
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 741
Distributed by
Pinturas para Mantenimiento
PERFIL DE ANCLAJE (MILS) TIPO DE ABRASIVO NOTAS
05 80120 ARENA 90 PSI
1 3060 ARENA
15 2050 ARENA
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
2 1640 ARENA
25 1230 ARENA
3 820 ARENA
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 841
Distributed by
MEDICION DE ESPESOR HUMEDO
Consiste en medir la capa humeda de pintura recien aplicadapara realizar un seguimiento a los espesores que se estanmanejando
Pinturas para Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
Se puede calcular el espesor seco aproximado partiendo delespesor humedo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 941
Distributed by
SALES SOLUBLES
CLORUROS NITRATOS SULFATOS
microgcm2
microgcm2
microgcm2
Oil Company Tuberiacuteas 1 - -
NY State DOT Puentes 5 7 10Bridgecoat
Coatings Puentes 7 10 17
Inmersioacuten 5 - -
ENTIDAD SERVICIO
Shell Global US
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
mos r ca - -
Inmersioacuten 3 - -
Atmosfeacuterica 5 - -
EXXON Mobil 10 - -
Arizona Water Inmersioacuten 3 - -
(tanque agua) Atmosfeacuterica 5 - -
Inmersioacuten 3 - -
Atmosfeacuterica 5 -
Ecopetrol Todos 7 - 17
NAVSEA
Promigas SA
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1041
Distributed by
PREPARACION DE SUPERFICIE
PREPARACION DE SUPERFICIE
SE UTILIZAN CRITERIOS DE COMPARACION VISUAL
DEPENDE DEL ESTADO INICIAL DE LA LAMINA QUE SE HATRATADO Y DE LA PREPARACION DE SUPERFICIE UTILIZADA
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
GRADO COMERCIAL
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1141
Distributed by
PREPARACION DE SUPERFICIE
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1241
Distributed by
Pinturas para Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1341
Distributed by
MEDICION DE ESPESORES
bull Norma ldquosspc paint aplication specification ndeg 2Measurement of dry specification n 2rdquo
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
bull Procedimiento
bull Numero de mediciones
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1441
Distributed by
MEDICION DE ESPESORES
bull Calibracioacutenbull Debe ser calibrado anualmente en un laboratorio
autorizado
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Se debe calibrar antes de iniciar la medicionescon la laminilla mas cercana a los espesoresesperados
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1541
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1641
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1741
Distributed by
MEDICION DE ESPESORES
bull Procedimiento
bull Realizar 3 mediciones en un areacutea inferior a 1
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Promediar estos 3 datos hay que tener encuenta que ninguna medicioacuten debe ser inferior
al 80 del espesor especificado
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1841
Distributed by
NUMERO DE MEDICIONES
bull
Si el aacuterea es menor a 92 m2 tomar 5 muestreos
bull Si el aacuterea esta entre 92 m2 y 276 m2 medir cada 92 m2de acuerdo al numeral anterior
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Areas hasta 92 m2 escoger tres zonas de acuerdo alprimer numeral
bull Si es mayor a 92 m2 los primeros 92 m2 como el numeralanterior por cada 92 m2 tomar seguacuten el primer numeral
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1941
Distributed by
PRUEBAS DE ADHERENCIA POR CINTA
bullldquoEstandar test methodos for measuring adhesion bytape testrdquo norma astm d 3359
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
el contratista
bull En sistemas multicapas esta prueba generalmente
no muestra la adhesioacuten sobre el sustrato
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2041
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2141
Distributed by
PARA ESPESORES ENTRE 0 Y 2 MILS
bull Realizar una cuadricula de 25 partes a 1 mm dedistancia
bull A licar la cinta de arla entre 1 2 minutos
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull Calificar de acuerdo a los cuadros despegados 0b si sedespego mas del 65 hsta 5b que equivale a uncomportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2241
Distributed by
PARA ESPESORES ENTRE 2 Y 5 MILS
bull
Realizar una cuadricula de 25 partes a 2 mm dedistancia
bull
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull
Calificar de acuerdo a los cuadros despegados 0b si sedespego mas del 65 hsta 5b que equivale a uncomportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2341
Distributed by
PARA ESPESORES MAYORES A 5 MILS
bull
Realizar un corte en x con un angulo entre 30 y 45grados
bull
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull
Calificar de acuerdo a los cuadros despegados 0a si sedespego el cuadrado correspondiente a la x hasta 5aque equivale a un comportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2441
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2541
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Se realiza mediante la aplicacioacuten unos probadores o
Pinturas de Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
especiales y midiendo la tensioacuten aplicada paradespegar los mismos
bull Es una prueba de acuerdo con el cliente y el aplicador
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2641
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
de la pelicula como la cantidad de recubrimientosdespegados en el dado
bull La presion de ruptura esta de acuerdo a lossistemas aplicados y a la preparacioacuten de superficie
hecha
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2741
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull Procedimiento seguacuten norma astm d4541
bull Criterios(Seguacuten norma ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull a preparac on e super c e es a gra o comerc a yla pintura es base amida la tension minima es 710 psi
bull Si la preparacion de superficie es a grado comercial yla pintura es base amina la tension minima es 400 psi
bull
Si es poliuretano sobre pinturas aminas o amidas latension minima es 280 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2841
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios(Seguacuten norma icontec ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Si la preparacion es manual-mecanica la medicioncalificara indirectamente la calidad de la preparacion desuperficie
bull Si la pintura es un esmalte alquidico se debe esperar 15dias y la presion minima debe ser 250 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2941
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3041
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3141
Distributed by
PERFIL DE ANCLAJE
bull
Es la distancia promedio entre los picos y losvalles generados por la preparacion desuperficie
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Es una prueba de acuerdo cliente-aplicador
bull Se recomienda entre el 10 y el 15 del
espesor del sistema que se va a aplicar
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3241
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3341
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3441
Distributed by
PERFIL DE ANCLAJE
bull Se mide copiando el perfil mediante plaacutesticosespeciales y llevaacutendolo a un microacutemetro
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3541
Distributed by
CONDICIONES AMBIENTALES
bull Norma astm e337
bull Temperatura de chapabull Debe ser superior minimo en 3degc a la temperatura decrocio
bull Tem eratura ambiental
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
La reaccion de una pintura epoxica se detiene a menos de4degc
bull Humedad relativa
bull Se mide mediante higrometros ninguna pintura epoxica o
base solvente debe ser aplicada si la humedad relativa essuperior al 85
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3641
Distributed by
DETECCION DE DISCONTINUIDADES
bull Norma astm d 5162-91
bull Detectores bajo voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la pelicula mediantela circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se usa generalmente un detector entre 6 y 50 voltiosde corriente directa
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3741
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3841
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm d 5162-91
bull Detectores de alto voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se utilizan entre 1500 vol y 25000 vol
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3941
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm g 62-87
bull Detectores de alto voltaje para tuberias
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull
Se utilizan entre 1500 vol y 25000 volbull Los valores de prueba dependen de los
espesores del recubrimiento
Di t ib t d b
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4041
Distributed by
CONCLUSION
Para lograr un perfecto desempentildeo de unrecubrimiento debemos cubrir todas las fases delproceso de aplicacioacuten y seleccioacuten de forma integralEsto solo se lo ra con el total conocimiento or arte
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
de los involucrados de las teacutecnicas y caracteriacutesticasde los productos que usamos
Distributed by
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4141
Distributed by
Pinturas para mantenimiento
GRACIAS
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 841
Distributed by
MEDICION DE ESPESOR HUMEDO
Consiste en medir la capa humeda de pintura recien aplicadapara realizar un seguimiento a los espesores que se estanmanejando
Pinturas para Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
Se puede calcular el espesor seco aproximado partiendo delespesor humedo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 941
Distributed by
SALES SOLUBLES
CLORUROS NITRATOS SULFATOS
microgcm2
microgcm2
microgcm2
Oil Company Tuberiacuteas 1 - -
NY State DOT Puentes 5 7 10Bridgecoat
Coatings Puentes 7 10 17
Inmersioacuten 5 - -
ENTIDAD SERVICIO
Shell Global US
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
mos r ca - -
Inmersioacuten 3 - -
Atmosfeacuterica 5 - -
EXXON Mobil 10 - -
Arizona Water Inmersioacuten 3 - -
(tanque agua) Atmosfeacuterica 5 - -
Inmersioacuten 3 - -
Atmosfeacuterica 5 -
Ecopetrol Todos 7 - 17
NAVSEA
Promigas SA
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1041
Distributed by
PREPARACION DE SUPERFICIE
PREPARACION DE SUPERFICIE
SE UTILIZAN CRITERIOS DE COMPARACION VISUAL
DEPENDE DEL ESTADO INICIAL DE LA LAMINA QUE SE HATRATADO Y DE LA PREPARACION DE SUPERFICIE UTILIZADA
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
GRADO COMERCIAL
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1141
Distributed by
PREPARACION DE SUPERFICIE
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1241
Distributed by
Pinturas para Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1341
Distributed by
MEDICION DE ESPESORES
bull Norma ldquosspc paint aplication specification ndeg 2Measurement of dry specification n 2rdquo
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
bull Procedimiento
bull Numero de mediciones
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1441
Distributed by
MEDICION DE ESPESORES
bull Calibracioacutenbull Debe ser calibrado anualmente en un laboratorio
autorizado
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Se debe calibrar antes de iniciar la medicionescon la laminilla mas cercana a los espesoresesperados
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1541
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1641
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1741
Distributed by
MEDICION DE ESPESORES
bull Procedimiento
bull Realizar 3 mediciones en un areacutea inferior a 1
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Promediar estos 3 datos hay que tener encuenta que ninguna medicioacuten debe ser inferior
al 80 del espesor especificado
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1841
Distributed by
NUMERO DE MEDICIONES
bull
Si el aacuterea es menor a 92 m2 tomar 5 muestreos
bull Si el aacuterea esta entre 92 m2 y 276 m2 medir cada 92 m2de acuerdo al numeral anterior
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Areas hasta 92 m2 escoger tres zonas de acuerdo alprimer numeral
bull Si es mayor a 92 m2 los primeros 92 m2 como el numeralanterior por cada 92 m2 tomar seguacuten el primer numeral
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1941
Distributed by
PRUEBAS DE ADHERENCIA POR CINTA
bullldquoEstandar test methodos for measuring adhesion bytape testrdquo norma astm d 3359
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
el contratista
bull En sistemas multicapas esta prueba generalmente
no muestra la adhesioacuten sobre el sustrato
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2041
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2141
Distributed by
PARA ESPESORES ENTRE 0 Y 2 MILS
bull Realizar una cuadricula de 25 partes a 1 mm dedistancia
bull A licar la cinta de arla entre 1 2 minutos
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull Calificar de acuerdo a los cuadros despegados 0b si sedespego mas del 65 hsta 5b que equivale a uncomportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2241
Distributed by
PARA ESPESORES ENTRE 2 Y 5 MILS
bull
Realizar una cuadricula de 25 partes a 2 mm dedistancia
bull
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull
Calificar de acuerdo a los cuadros despegados 0b si sedespego mas del 65 hsta 5b que equivale a uncomportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2341
Distributed by
PARA ESPESORES MAYORES A 5 MILS
bull
Realizar un corte en x con un angulo entre 30 y 45grados
bull
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull
Calificar de acuerdo a los cuadros despegados 0a si sedespego el cuadrado correspondiente a la x hasta 5aque equivale a un comportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2441
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2541
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Se realiza mediante la aplicacioacuten unos probadores o
Pinturas de Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
especiales y midiendo la tensioacuten aplicada paradespegar los mismos
bull Es una prueba de acuerdo con el cliente y el aplicador
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2641
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
de la pelicula como la cantidad de recubrimientosdespegados en el dado
bull La presion de ruptura esta de acuerdo a lossistemas aplicados y a la preparacioacuten de superficie
hecha
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2741
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull Procedimiento seguacuten norma astm d4541
bull Criterios(Seguacuten norma ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull a preparac on e super c e es a gra o comerc a yla pintura es base amida la tension minima es 710 psi
bull Si la preparacion de superficie es a grado comercial yla pintura es base amina la tension minima es 400 psi
bull
Si es poliuretano sobre pinturas aminas o amidas latension minima es 280 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2841
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios(Seguacuten norma icontec ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Si la preparacion es manual-mecanica la medicioncalificara indirectamente la calidad de la preparacion desuperficie
bull Si la pintura es un esmalte alquidico se debe esperar 15dias y la presion minima debe ser 250 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2941
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3041
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3141
Distributed by
PERFIL DE ANCLAJE
bull
Es la distancia promedio entre los picos y losvalles generados por la preparacion desuperficie
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Es una prueba de acuerdo cliente-aplicador
bull Se recomienda entre el 10 y el 15 del
espesor del sistema que se va a aplicar
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3241
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3341
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3441
Distributed by
PERFIL DE ANCLAJE
bull Se mide copiando el perfil mediante plaacutesticosespeciales y llevaacutendolo a un microacutemetro
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3541
Distributed by
CONDICIONES AMBIENTALES
bull Norma astm e337
bull Temperatura de chapabull Debe ser superior minimo en 3degc a la temperatura decrocio
bull Tem eratura ambiental
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
La reaccion de una pintura epoxica se detiene a menos de4degc
bull Humedad relativa
bull Se mide mediante higrometros ninguna pintura epoxica o
base solvente debe ser aplicada si la humedad relativa essuperior al 85
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3641
Distributed by
DETECCION DE DISCONTINUIDADES
bull Norma astm d 5162-91
bull Detectores bajo voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la pelicula mediantela circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se usa generalmente un detector entre 6 y 50 voltiosde corriente directa
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3741
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3841
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm d 5162-91
bull Detectores de alto voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se utilizan entre 1500 vol y 25000 vol
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3941
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm g 62-87
bull Detectores de alto voltaje para tuberias
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull
Se utilizan entre 1500 vol y 25000 volbull Los valores de prueba dependen de los
espesores del recubrimiento
Di t ib t d b
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4041
Distributed by
CONCLUSION
Para lograr un perfecto desempentildeo de unrecubrimiento debemos cubrir todas las fases delproceso de aplicacioacuten y seleccioacuten de forma integralEsto solo se lo ra con el total conocimiento or arte
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
de los involucrados de las teacutecnicas y caracteriacutesticasde los productos que usamos
Distributed by
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4141
Distributed by
Pinturas para mantenimiento
GRACIAS
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 941
Distributed by
SALES SOLUBLES
CLORUROS NITRATOS SULFATOS
microgcm2
microgcm2
microgcm2
Oil Company Tuberiacuteas 1 - -
NY State DOT Puentes 5 7 10Bridgecoat
Coatings Puentes 7 10 17
Inmersioacuten 5 - -
ENTIDAD SERVICIO
Shell Global US
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
mos r ca - -
Inmersioacuten 3 - -
Atmosfeacuterica 5 - -
EXXON Mobil 10 - -
Arizona Water Inmersioacuten 3 - -
(tanque agua) Atmosfeacuterica 5 - -
Inmersioacuten 3 - -
Atmosfeacuterica 5 -
Ecopetrol Todos 7 - 17
NAVSEA
Promigas SA
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1041
Distributed by
PREPARACION DE SUPERFICIE
PREPARACION DE SUPERFICIE
SE UTILIZAN CRITERIOS DE COMPARACION VISUAL
DEPENDE DEL ESTADO INICIAL DE LA LAMINA QUE SE HATRATADO Y DE LA PREPARACION DE SUPERFICIE UTILIZADA
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
GRADO COMERCIAL
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1141
Distributed by
PREPARACION DE SUPERFICIE
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1241
Distributed by
Pinturas para Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1341
Distributed by
MEDICION DE ESPESORES
bull Norma ldquosspc paint aplication specification ndeg 2Measurement of dry specification n 2rdquo
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
bull Procedimiento
bull Numero de mediciones
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1441
Distributed by
MEDICION DE ESPESORES
bull Calibracioacutenbull Debe ser calibrado anualmente en un laboratorio
autorizado
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Se debe calibrar antes de iniciar la medicionescon la laminilla mas cercana a los espesoresesperados
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1541
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1641
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1741
Distributed by
MEDICION DE ESPESORES
bull Procedimiento
bull Realizar 3 mediciones en un areacutea inferior a 1
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Promediar estos 3 datos hay que tener encuenta que ninguna medicioacuten debe ser inferior
al 80 del espesor especificado
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1841
Distributed by
NUMERO DE MEDICIONES
bull
Si el aacuterea es menor a 92 m2 tomar 5 muestreos
bull Si el aacuterea esta entre 92 m2 y 276 m2 medir cada 92 m2de acuerdo al numeral anterior
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Areas hasta 92 m2 escoger tres zonas de acuerdo alprimer numeral
bull Si es mayor a 92 m2 los primeros 92 m2 como el numeralanterior por cada 92 m2 tomar seguacuten el primer numeral
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1941
Distributed by
PRUEBAS DE ADHERENCIA POR CINTA
bullldquoEstandar test methodos for measuring adhesion bytape testrdquo norma astm d 3359
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
el contratista
bull En sistemas multicapas esta prueba generalmente
no muestra la adhesioacuten sobre el sustrato
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2041
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2141
Distributed by
PARA ESPESORES ENTRE 0 Y 2 MILS
bull Realizar una cuadricula de 25 partes a 1 mm dedistancia
bull A licar la cinta de arla entre 1 2 minutos
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull Calificar de acuerdo a los cuadros despegados 0b si sedespego mas del 65 hsta 5b que equivale a uncomportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2241
Distributed by
PARA ESPESORES ENTRE 2 Y 5 MILS
bull
Realizar una cuadricula de 25 partes a 2 mm dedistancia
bull
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull
Calificar de acuerdo a los cuadros despegados 0b si sedespego mas del 65 hsta 5b que equivale a uncomportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2341
Distributed by
PARA ESPESORES MAYORES A 5 MILS
bull
Realizar un corte en x con un angulo entre 30 y 45grados
bull
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull
Calificar de acuerdo a los cuadros despegados 0a si sedespego el cuadrado correspondiente a la x hasta 5aque equivale a un comportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2441
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2541
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Se realiza mediante la aplicacioacuten unos probadores o
Pinturas de Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
especiales y midiendo la tensioacuten aplicada paradespegar los mismos
bull Es una prueba de acuerdo con el cliente y el aplicador
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2641
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
de la pelicula como la cantidad de recubrimientosdespegados en el dado
bull La presion de ruptura esta de acuerdo a lossistemas aplicados y a la preparacioacuten de superficie
hecha
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2741
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull Procedimiento seguacuten norma astm d4541
bull Criterios(Seguacuten norma ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull a preparac on e super c e es a gra o comerc a yla pintura es base amida la tension minima es 710 psi
bull Si la preparacion de superficie es a grado comercial yla pintura es base amina la tension minima es 400 psi
bull
Si es poliuretano sobre pinturas aminas o amidas latension minima es 280 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2841
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios(Seguacuten norma icontec ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Si la preparacion es manual-mecanica la medicioncalificara indirectamente la calidad de la preparacion desuperficie
bull Si la pintura es un esmalte alquidico se debe esperar 15dias y la presion minima debe ser 250 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2941
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3041
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3141
Distributed by
PERFIL DE ANCLAJE
bull
Es la distancia promedio entre los picos y losvalles generados por la preparacion desuperficie
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Es una prueba de acuerdo cliente-aplicador
bull Se recomienda entre el 10 y el 15 del
espesor del sistema que se va a aplicar
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3241
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3341
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3441
Distributed by
PERFIL DE ANCLAJE
bull Se mide copiando el perfil mediante plaacutesticosespeciales y llevaacutendolo a un microacutemetro
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3541
Distributed by
CONDICIONES AMBIENTALES
bull Norma astm e337
bull Temperatura de chapabull Debe ser superior minimo en 3degc a la temperatura decrocio
bull Tem eratura ambiental
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
La reaccion de una pintura epoxica se detiene a menos de4degc
bull Humedad relativa
bull Se mide mediante higrometros ninguna pintura epoxica o
base solvente debe ser aplicada si la humedad relativa essuperior al 85
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3641
Distributed by
DETECCION DE DISCONTINUIDADES
bull Norma astm d 5162-91
bull Detectores bajo voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la pelicula mediantela circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se usa generalmente un detector entre 6 y 50 voltiosde corriente directa
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3741
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3841
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm d 5162-91
bull Detectores de alto voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se utilizan entre 1500 vol y 25000 vol
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3941
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm g 62-87
bull Detectores de alto voltaje para tuberias
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull
Se utilizan entre 1500 vol y 25000 volbull Los valores de prueba dependen de los
espesores del recubrimiento
Di t ib t d b
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4041
Distributed by
CONCLUSION
Para lograr un perfecto desempentildeo de unrecubrimiento debemos cubrir todas las fases delproceso de aplicacioacuten y seleccioacuten de forma integralEsto solo se lo ra con el total conocimiento or arte
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
de los involucrados de las teacutecnicas y caracteriacutesticasde los productos que usamos
Distributed by
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4141
Distributed by
Pinturas para mantenimiento
GRACIAS
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1041
Distributed by
PREPARACION DE SUPERFICIE
PREPARACION DE SUPERFICIE
SE UTILIZAN CRITERIOS DE COMPARACION VISUAL
DEPENDE DEL ESTADO INICIAL DE LA LAMINA QUE SE HATRATADO Y DE LA PREPARACION DE SUPERFICIE UTILIZADA
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
GRADO COMERCIAL
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1141
Distributed by
PREPARACION DE SUPERFICIE
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1241
Distributed by
Pinturas para Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1341
Distributed by
MEDICION DE ESPESORES
bull Norma ldquosspc paint aplication specification ndeg 2Measurement of dry specification n 2rdquo
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
bull Procedimiento
bull Numero de mediciones
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1441
Distributed by
MEDICION DE ESPESORES
bull Calibracioacutenbull Debe ser calibrado anualmente en un laboratorio
autorizado
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Se debe calibrar antes de iniciar la medicionescon la laminilla mas cercana a los espesoresesperados
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1541
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1641
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1741
Distributed by
MEDICION DE ESPESORES
bull Procedimiento
bull Realizar 3 mediciones en un areacutea inferior a 1
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Promediar estos 3 datos hay que tener encuenta que ninguna medicioacuten debe ser inferior
al 80 del espesor especificado
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1841
Distributed by
NUMERO DE MEDICIONES
bull
Si el aacuterea es menor a 92 m2 tomar 5 muestreos
bull Si el aacuterea esta entre 92 m2 y 276 m2 medir cada 92 m2de acuerdo al numeral anterior
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Areas hasta 92 m2 escoger tres zonas de acuerdo alprimer numeral
bull Si es mayor a 92 m2 los primeros 92 m2 como el numeralanterior por cada 92 m2 tomar seguacuten el primer numeral
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1941
Distributed by
PRUEBAS DE ADHERENCIA POR CINTA
bullldquoEstandar test methodos for measuring adhesion bytape testrdquo norma astm d 3359
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
el contratista
bull En sistemas multicapas esta prueba generalmente
no muestra la adhesioacuten sobre el sustrato
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2041
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2141
Distributed by
PARA ESPESORES ENTRE 0 Y 2 MILS
bull Realizar una cuadricula de 25 partes a 1 mm dedistancia
bull A licar la cinta de arla entre 1 2 minutos
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull Calificar de acuerdo a los cuadros despegados 0b si sedespego mas del 65 hsta 5b que equivale a uncomportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2241
Distributed by
PARA ESPESORES ENTRE 2 Y 5 MILS
bull
Realizar una cuadricula de 25 partes a 2 mm dedistancia
bull
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull
Calificar de acuerdo a los cuadros despegados 0b si sedespego mas del 65 hsta 5b que equivale a uncomportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2341
Distributed by
PARA ESPESORES MAYORES A 5 MILS
bull
Realizar un corte en x con un angulo entre 30 y 45grados
bull
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull
Calificar de acuerdo a los cuadros despegados 0a si sedespego el cuadrado correspondiente a la x hasta 5aque equivale a un comportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2441
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2541
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Se realiza mediante la aplicacioacuten unos probadores o
Pinturas de Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
especiales y midiendo la tensioacuten aplicada paradespegar los mismos
bull Es una prueba de acuerdo con el cliente y el aplicador
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2641
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
de la pelicula como la cantidad de recubrimientosdespegados en el dado
bull La presion de ruptura esta de acuerdo a lossistemas aplicados y a la preparacioacuten de superficie
hecha
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2741
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull Procedimiento seguacuten norma astm d4541
bull Criterios(Seguacuten norma ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull a preparac on e super c e es a gra o comerc a yla pintura es base amida la tension minima es 710 psi
bull Si la preparacion de superficie es a grado comercial yla pintura es base amina la tension minima es 400 psi
bull
Si es poliuretano sobre pinturas aminas o amidas latension minima es 280 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2841
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios(Seguacuten norma icontec ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Si la preparacion es manual-mecanica la medicioncalificara indirectamente la calidad de la preparacion desuperficie
bull Si la pintura es un esmalte alquidico se debe esperar 15dias y la presion minima debe ser 250 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2941
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3041
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3141
Distributed by
PERFIL DE ANCLAJE
bull
Es la distancia promedio entre los picos y losvalles generados por la preparacion desuperficie
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Es una prueba de acuerdo cliente-aplicador
bull Se recomienda entre el 10 y el 15 del
espesor del sistema que se va a aplicar
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3241
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3341
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3441
Distributed by
PERFIL DE ANCLAJE
bull Se mide copiando el perfil mediante plaacutesticosespeciales y llevaacutendolo a un microacutemetro
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3541
Distributed by
CONDICIONES AMBIENTALES
bull Norma astm e337
bull Temperatura de chapabull Debe ser superior minimo en 3degc a la temperatura decrocio
bull Tem eratura ambiental
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
La reaccion de una pintura epoxica se detiene a menos de4degc
bull Humedad relativa
bull Se mide mediante higrometros ninguna pintura epoxica o
base solvente debe ser aplicada si la humedad relativa essuperior al 85
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3641
Distributed by
DETECCION DE DISCONTINUIDADES
bull Norma astm d 5162-91
bull Detectores bajo voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la pelicula mediantela circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se usa generalmente un detector entre 6 y 50 voltiosde corriente directa
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3741
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3841
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm d 5162-91
bull Detectores de alto voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se utilizan entre 1500 vol y 25000 vol
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3941
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm g 62-87
bull Detectores de alto voltaje para tuberias
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull
Se utilizan entre 1500 vol y 25000 volbull Los valores de prueba dependen de los
espesores del recubrimiento
Di t ib t d b
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4041
Distributed by
CONCLUSION
Para lograr un perfecto desempentildeo de unrecubrimiento debemos cubrir todas las fases delproceso de aplicacioacuten y seleccioacuten de forma integralEsto solo se lo ra con el total conocimiento or arte
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
de los involucrados de las teacutecnicas y caracteriacutesticasde los productos que usamos
Distributed by
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4141
Distributed by
Pinturas para mantenimiento
GRACIAS
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1141
Distributed by
PREPARACION DE SUPERFICIE
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1241
Distributed by
Pinturas para Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1341
Distributed by
MEDICION DE ESPESORES
bull Norma ldquosspc paint aplication specification ndeg 2Measurement of dry specification n 2rdquo
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
bull Procedimiento
bull Numero de mediciones
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1441
Distributed by
MEDICION DE ESPESORES
bull Calibracioacutenbull Debe ser calibrado anualmente en un laboratorio
autorizado
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Se debe calibrar antes de iniciar la medicionescon la laminilla mas cercana a los espesoresesperados
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1541
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1641
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1741
Distributed by
MEDICION DE ESPESORES
bull Procedimiento
bull Realizar 3 mediciones en un areacutea inferior a 1
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Promediar estos 3 datos hay que tener encuenta que ninguna medicioacuten debe ser inferior
al 80 del espesor especificado
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1841
Distributed by
NUMERO DE MEDICIONES
bull
Si el aacuterea es menor a 92 m2 tomar 5 muestreos
bull Si el aacuterea esta entre 92 m2 y 276 m2 medir cada 92 m2de acuerdo al numeral anterior
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Areas hasta 92 m2 escoger tres zonas de acuerdo alprimer numeral
bull Si es mayor a 92 m2 los primeros 92 m2 como el numeralanterior por cada 92 m2 tomar seguacuten el primer numeral
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1941
Distributed by
PRUEBAS DE ADHERENCIA POR CINTA
bullldquoEstandar test methodos for measuring adhesion bytape testrdquo norma astm d 3359
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
el contratista
bull En sistemas multicapas esta prueba generalmente
no muestra la adhesioacuten sobre el sustrato
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2041
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2141
Distributed by
PARA ESPESORES ENTRE 0 Y 2 MILS
bull Realizar una cuadricula de 25 partes a 1 mm dedistancia
bull A licar la cinta de arla entre 1 2 minutos
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull Calificar de acuerdo a los cuadros despegados 0b si sedespego mas del 65 hsta 5b que equivale a uncomportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2241
Distributed by
PARA ESPESORES ENTRE 2 Y 5 MILS
bull
Realizar una cuadricula de 25 partes a 2 mm dedistancia
bull
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull
Calificar de acuerdo a los cuadros despegados 0b si sedespego mas del 65 hsta 5b que equivale a uncomportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2341
Distributed by
PARA ESPESORES MAYORES A 5 MILS
bull
Realizar un corte en x con un angulo entre 30 y 45grados
bull
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull
Calificar de acuerdo a los cuadros despegados 0a si sedespego el cuadrado correspondiente a la x hasta 5aque equivale a un comportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2441
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2541
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Se realiza mediante la aplicacioacuten unos probadores o
Pinturas de Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
especiales y midiendo la tensioacuten aplicada paradespegar los mismos
bull Es una prueba de acuerdo con el cliente y el aplicador
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2641
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
de la pelicula como la cantidad de recubrimientosdespegados en el dado
bull La presion de ruptura esta de acuerdo a lossistemas aplicados y a la preparacioacuten de superficie
hecha
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2741
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull Procedimiento seguacuten norma astm d4541
bull Criterios(Seguacuten norma ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull a preparac on e super c e es a gra o comerc a yla pintura es base amida la tension minima es 710 psi
bull Si la preparacion de superficie es a grado comercial yla pintura es base amina la tension minima es 400 psi
bull
Si es poliuretano sobre pinturas aminas o amidas latension minima es 280 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2841
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios(Seguacuten norma icontec ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Si la preparacion es manual-mecanica la medicioncalificara indirectamente la calidad de la preparacion desuperficie
bull Si la pintura es un esmalte alquidico se debe esperar 15dias y la presion minima debe ser 250 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2941
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3041
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3141
Distributed by
PERFIL DE ANCLAJE
bull
Es la distancia promedio entre los picos y losvalles generados por la preparacion desuperficie
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Es una prueba de acuerdo cliente-aplicador
bull Se recomienda entre el 10 y el 15 del
espesor del sistema que se va a aplicar
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3241
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3341
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3441
Distributed by
PERFIL DE ANCLAJE
bull Se mide copiando el perfil mediante plaacutesticosespeciales y llevaacutendolo a un microacutemetro
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3541
Distributed by
CONDICIONES AMBIENTALES
bull Norma astm e337
bull Temperatura de chapabull Debe ser superior minimo en 3degc a la temperatura decrocio
bull Tem eratura ambiental
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
La reaccion de una pintura epoxica se detiene a menos de4degc
bull Humedad relativa
bull Se mide mediante higrometros ninguna pintura epoxica o
base solvente debe ser aplicada si la humedad relativa essuperior al 85
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3641
Distributed by
DETECCION DE DISCONTINUIDADES
bull Norma astm d 5162-91
bull Detectores bajo voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la pelicula mediantela circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se usa generalmente un detector entre 6 y 50 voltiosde corriente directa
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3741
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3841
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm d 5162-91
bull Detectores de alto voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se utilizan entre 1500 vol y 25000 vol
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3941
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm g 62-87
bull Detectores de alto voltaje para tuberias
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull
Se utilizan entre 1500 vol y 25000 volbull Los valores de prueba dependen de los
espesores del recubrimiento
Di t ib t d b
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4041
Distributed by
CONCLUSION
Para lograr un perfecto desempentildeo de unrecubrimiento debemos cubrir todas las fases delproceso de aplicacioacuten y seleccioacuten de forma integralEsto solo se lo ra con el total conocimiento or arte
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
de los involucrados de las teacutecnicas y caracteriacutesticasde los productos que usamos
Distributed by
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4141
Distributed by
Pinturas para mantenimiento
GRACIAS
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1241
Distributed by
Pinturas para Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1341
Distributed by
MEDICION DE ESPESORES
bull Norma ldquosspc paint aplication specification ndeg 2Measurement of dry specification n 2rdquo
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
bull Procedimiento
bull Numero de mediciones
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1441
Distributed by
MEDICION DE ESPESORES
bull Calibracioacutenbull Debe ser calibrado anualmente en un laboratorio
autorizado
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Se debe calibrar antes de iniciar la medicionescon la laminilla mas cercana a los espesoresesperados
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1541
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1641
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1741
Distributed by
MEDICION DE ESPESORES
bull Procedimiento
bull Realizar 3 mediciones en un areacutea inferior a 1
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Promediar estos 3 datos hay que tener encuenta que ninguna medicioacuten debe ser inferior
al 80 del espesor especificado
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1841
Distributed by
NUMERO DE MEDICIONES
bull
Si el aacuterea es menor a 92 m2 tomar 5 muestreos
bull Si el aacuterea esta entre 92 m2 y 276 m2 medir cada 92 m2de acuerdo al numeral anterior
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Areas hasta 92 m2 escoger tres zonas de acuerdo alprimer numeral
bull Si es mayor a 92 m2 los primeros 92 m2 como el numeralanterior por cada 92 m2 tomar seguacuten el primer numeral
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1941
Distributed by
PRUEBAS DE ADHERENCIA POR CINTA
bullldquoEstandar test methodos for measuring adhesion bytape testrdquo norma astm d 3359
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
el contratista
bull En sistemas multicapas esta prueba generalmente
no muestra la adhesioacuten sobre el sustrato
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2041
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2141
Distributed by
PARA ESPESORES ENTRE 0 Y 2 MILS
bull Realizar una cuadricula de 25 partes a 1 mm dedistancia
bull A licar la cinta de arla entre 1 2 minutos
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull Calificar de acuerdo a los cuadros despegados 0b si sedespego mas del 65 hsta 5b que equivale a uncomportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2241
Distributed by
PARA ESPESORES ENTRE 2 Y 5 MILS
bull
Realizar una cuadricula de 25 partes a 2 mm dedistancia
bull
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull
Calificar de acuerdo a los cuadros despegados 0b si sedespego mas del 65 hsta 5b que equivale a uncomportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2341
Distributed by
PARA ESPESORES MAYORES A 5 MILS
bull
Realizar un corte en x con un angulo entre 30 y 45grados
bull
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull
Calificar de acuerdo a los cuadros despegados 0a si sedespego el cuadrado correspondiente a la x hasta 5aque equivale a un comportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2441
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2541
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Se realiza mediante la aplicacioacuten unos probadores o
Pinturas de Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
especiales y midiendo la tensioacuten aplicada paradespegar los mismos
bull Es una prueba de acuerdo con el cliente y el aplicador
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2641
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
de la pelicula como la cantidad de recubrimientosdespegados en el dado
bull La presion de ruptura esta de acuerdo a lossistemas aplicados y a la preparacioacuten de superficie
hecha
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2741
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull Procedimiento seguacuten norma astm d4541
bull Criterios(Seguacuten norma ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull a preparac on e super c e es a gra o comerc a yla pintura es base amida la tension minima es 710 psi
bull Si la preparacion de superficie es a grado comercial yla pintura es base amina la tension minima es 400 psi
bull
Si es poliuretano sobre pinturas aminas o amidas latension minima es 280 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2841
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios(Seguacuten norma icontec ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Si la preparacion es manual-mecanica la medicioncalificara indirectamente la calidad de la preparacion desuperficie
bull Si la pintura es un esmalte alquidico se debe esperar 15dias y la presion minima debe ser 250 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2941
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3041
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3141
Distributed by
PERFIL DE ANCLAJE
bull
Es la distancia promedio entre los picos y losvalles generados por la preparacion desuperficie
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Es una prueba de acuerdo cliente-aplicador
bull Se recomienda entre el 10 y el 15 del
espesor del sistema que se va a aplicar
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3241
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3341
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3441
Distributed by
PERFIL DE ANCLAJE
bull Se mide copiando el perfil mediante plaacutesticosespeciales y llevaacutendolo a un microacutemetro
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3541
Distributed by
CONDICIONES AMBIENTALES
bull Norma astm e337
bull Temperatura de chapabull Debe ser superior minimo en 3degc a la temperatura decrocio
bull Tem eratura ambiental
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
La reaccion de una pintura epoxica se detiene a menos de4degc
bull Humedad relativa
bull Se mide mediante higrometros ninguna pintura epoxica o
base solvente debe ser aplicada si la humedad relativa essuperior al 85
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3641
Distributed by
DETECCION DE DISCONTINUIDADES
bull Norma astm d 5162-91
bull Detectores bajo voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la pelicula mediantela circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se usa generalmente un detector entre 6 y 50 voltiosde corriente directa
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3741
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3841
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm d 5162-91
bull Detectores de alto voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se utilizan entre 1500 vol y 25000 vol
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3941
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm g 62-87
bull Detectores de alto voltaje para tuberias
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull
Se utilizan entre 1500 vol y 25000 volbull Los valores de prueba dependen de los
espesores del recubrimiento
Di t ib t d b
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4041
Distributed by
CONCLUSION
Para lograr un perfecto desempentildeo de unrecubrimiento debemos cubrir todas las fases delproceso de aplicacioacuten y seleccioacuten de forma integralEsto solo se lo ra con el total conocimiento or arte
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
de los involucrados de las teacutecnicas y caracteriacutesticasde los productos que usamos
Distributed by
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4141
Distributed by
Pinturas para mantenimiento
GRACIAS
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1341
Distributed by
MEDICION DE ESPESORES
bull Norma ldquosspc paint aplication specification ndeg 2Measurement of dry specification n 2rdquo
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
bull Procedimiento
bull Numero de mediciones
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1441
Distributed by
MEDICION DE ESPESORES
bull Calibracioacutenbull Debe ser calibrado anualmente en un laboratorio
autorizado
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Se debe calibrar antes de iniciar la medicionescon la laminilla mas cercana a los espesoresesperados
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1541
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1641
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1741
Distributed by
MEDICION DE ESPESORES
bull Procedimiento
bull Realizar 3 mediciones en un areacutea inferior a 1
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Promediar estos 3 datos hay que tener encuenta que ninguna medicioacuten debe ser inferior
al 80 del espesor especificado
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1841
Distributed by
NUMERO DE MEDICIONES
bull
Si el aacuterea es menor a 92 m2 tomar 5 muestreos
bull Si el aacuterea esta entre 92 m2 y 276 m2 medir cada 92 m2de acuerdo al numeral anterior
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Areas hasta 92 m2 escoger tres zonas de acuerdo alprimer numeral
bull Si es mayor a 92 m2 los primeros 92 m2 como el numeralanterior por cada 92 m2 tomar seguacuten el primer numeral
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1941
Distributed by
PRUEBAS DE ADHERENCIA POR CINTA
bullldquoEstandar test methodos for measuring adhesion bytape testrdquo norma astm d 3359
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
el contratista
bull En sistemas multicapas esta prueba generalmente
no muestra la adhesioacuten sobre el sustrato
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2041
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2141
Distributed by
PARA ESPESORES ENTRE 0 Y 2 MILS
bull Realizar una cuadricula de 25 partes a 1 mm dedistancia
bull A licar la cinta de arla entre 1 2 minutos
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull Calificar de acuerdo a los cuadros despegados 0b si sedespego mas del 65 hsta 5b que equivale a uncomportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2241
Distributed by
PARA ESPESORES ENTRE 2 Y 5 MILS
bull
Realizar una cuadricula de 25 partes a 2 mm dedistancia
bull
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull
Calificar de acuerdo a los cuadros despegados 0b si sedespego mas del 65 hsta 5b que equivale a uncomportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2341
Distributed by
PARA ESPESORES MAYORES A 5 MILS
bull
Realizar un corte en x con un angulo entre 30 y 45grados
bull
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull
Calificar de acuerdo a los cuadros despegados 0a si sedespego el cuadrado correspondiente a la x hasta 5aque equivale a un comportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2441
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2541
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Se realiza mediante la aplicacioacuten unos probadores o
Pinturas de Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
especiales y midiendo la tensioacuten aplicada paradespegar los mismos
bull Es una prueba de acuerdo con el cliente y el aplicador
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2641
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
de la pelicula como la cantidad de recubrimientosdespegados en el dado
bull La presion de ruptura esta de acuerdo a lossistemas aplicados y a la preparacioacuten de superficie
hecha
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2741
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull Procedimiento seguacuten norma astm d4541
bull Criterios(Seguacuten norma ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull a preparac on e super c e es a gra o comerc a yla pintura es base amida la tension minima es 710 psi
bull Si la preparacion de superficie es a grado comercial yla pintura es base amina la tension minima es 400 psi
bull
Si es poliuretano sobre pinturas aminas o amidas latension minima es 280 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2841
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios(Seguacuten norma icontec ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Si la preparacion es manual-mecanica la medicioncalificara indirectamente la calidad de la preparacion desuperficie
bull Si la pintura es un esmalte alquidico se debe esperar 15dias y la presion minima debe ser 250 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2941
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3041
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3141
Distributed by
PERFIL DE ANCLAJE
bull
Es la distancia promedio entre los picos y losvalles generados por la preparacion desuperficie
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Es una prueba de acuerdo cliente-aplicador
bull Se recomienda entre el 10 y el 15 del
espesor del sistema que se va a aplicar
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3241
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3341
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3441
Distributed by
PERFIL DE ANCLAJE
bull Se mide copiando el perfil mediante plaacutesticosespeciales y llevaacutendolo a un microacutemetro
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3541
Distributed by
CONDICIONES AMBIENTALES
bull Norma astm e337
bull Temperatura de chapabull Debe ser superior minimo en 3degc a la temperatura decrocio
bull Tem eratura ambiental
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
La reaccion de una pintura epoxica se detiene a menos de4degc
bull Humedad relativa
bull Se mide mediante higrometros ninguna pintura epoxica o
base solvente debe ser aplicada si la humedad relativa essuperior al 85
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3641
Distributed by
DETECCION DE DISCONTINUIDADES
bull Norma astm d 5162-91
bull Detectores bajo voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la pelicula mediantela circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se usa generalmente un detector entre 6 y 50 voltiosde corriente directa
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3741
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3841
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm d 5162-91
bull Detectores de alto voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se utilizan entre 1500 vol y 25000 vol
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3941
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm g 62-87
bull Detectores de alto voltaje para tuberias
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull
Se utilizan entre 1500 vol y 25000 volbull Los valores de prueba dependen de los
espesores del recubrimiento
Di t ib t d b
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4041
Distributed by
CONCLUSION
Para lograr un perfecto desempentildeo de unrecubrimiento debemos cubrir todas las fases delproceso de aplicacioacuten y seleccioacuten de forma integralEsto solo se lo ra con el total conocimiento or arte
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
de los involucrados de las teacutecnicas y caracteriacutesticasde los productos que usamos
Distributed by
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4141
Distributed by
Pinturas para mantenimiento
GRACIAS
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1441
Distributed by
MEDICION DE ESPESORES
bull Calibracioacutenbull Debe ser calibrado anualmente en un laboratorio
autorizado
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Se debe calibrar antes de iniciar la medicionescon la laminilla mas cercana a los espesoresesperados
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1541
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1641
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1741
Distributed by
MEDICION DE ESPESORES
bull Procedimiento
bull Realizar 3 mediciones en un areacutea inferior a 1
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Promediar estos 3 datos hay que tener encuenta que ninguna medicioacuten debe ser inferior
al 80 del espesor especificado
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1841
Distributed by
NUMERO DE MEDICIONES
bull
Si el aacuterea es menor a 92 m2 tomar 5 muestreos
bull Si el aacuterea esta entre 92 m2 y 276 m2 medir cada 92 m2de acuerdo al numeral anterior
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Areas hasta 92 m2 escoger tres zonas de acuerdo alprimer numeral
bull Si es mayor a 92 m2 los primeros 92 m2 como el numeralanterior por cada 92 m2 tomar seguacuten el primer numeral
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1941
Distributed by
PRUEBAS DE ADHERENCIA POR CINTA
bullldquoEstandar test methodos for measuring adhesion bytape testrdquo norma astm d 3359
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
el contratista
bull En sistemas multicapas esta prueba generalmente
no muestra la adhesioacuten sobre el sustrato
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2041
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2141
Distributed by
PARA ESPESORES ENTRE 0 Y 2 MILS
bull Realizar una cuadricula de 25 partes a 1 mm dedistancia
bull A licar la cinta de arla entre 1 2 minutos
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull Calificar de acuerdo a los cuadros despegados 0b si sedespego mas del 65 hsta 5b que equivale a uncomportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2241
Distributed by
PARA ESPESORES ENTRE 2 Y 5 MILS
bull
Realizar una cuadricula de 25 partes a 2 mm dedistancia
bull
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull
Calificar de acuerdo a los cuadros despegados 0b si sedespego mas del 65 hsta 5b que equivale a uncomportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2341
Distributed by
PARA ESPESORES MAYORES A 5 MILS
bull
Realizar un corte en x con un angulo entre 30 y 45grados
bull
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull
Calificar de acuerdo a los cuadros despegados 0a si sedespego el cuadrado correspondiente a la x hasta 5aque equivale a un comportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2441
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2541
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Se realiza mediante la aplicacioacuten unos probadores o
Pinturas de Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
especiales y midiendo la tensioacuten aplicada paradespegar los mismos
bull Es una prueba de acuerdo con el cliente y el aplicador
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2641
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
de la pelicula como la cantidad de recubrimientosdespegados en el dado
bull La presion de ruptura esta de acuerdo a lossistemas aplicados y a la preparacioacuten de superficie
hecha
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2741
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull Procedimiento seguacuten norma astm d4541
bull Criterios(Seguacuten norma ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull a preparac on e super c e es a gra o comerc a yla pintura es base amida la tension minima es 710 psi
bull Si la preparacion de superficie es a grado comercial yla pintura es base amina la tension minima es 400 psi
bull
Si es poliuretano sobre pinturas aminas o amidas latension minima es 280 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2841
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios(Seguacuten norma icontec ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Si la preparacion es manual-mecanica la medicioncalificara indirectamente la calidad de la preparacion desuperficie
bull Si la pintura es un esmalte alquidico se debe esperar 15dias y la presion minima debe ser 250 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2941
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3041
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3141
Distributed by
PERFIL DE ANCLAJE
bull
Es la distancia promedio entre los picos y losvalles generados por la preparacion desuperficie
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Es una prueba de acuerdo cliente-aplicador
bull Se recomienda entre el 10 y el 15 del
espesor del sistema que se va a aplicar
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3241
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3341
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3441
Distributed by
PERFIL DE ANCLAJE
bull Se mide copiando el perfil mediante plaacutesticosespeciales y llevaacutendolo a un microacutemetro
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3541
Distributed by
CONDICIONES AMBIENTALES
bull Norma astm e337
bull Temperatura de chapabull Debe ser superior minimo en 3degc a la temperatura decrocio
bull Tem eratura ambiental
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
La reaccion de una pintura epoxica se detiene a menos de4degc
bull Humedad relativa
bull Se mide mediante higrometros ninguna pintura epoxica o
base solvente debe ser aplicada si la humedad relativa essuperior al 85
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3641
Distributed by
DETECCION DE DISCONTINUIDADES
bull Norma astm d 5162-91
bull Detectores bajo voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la pelicula mediantela circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se usa generalmente un detector entre 6 y 50 voltiosde corriente directa
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3741
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3841
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm d 5162-91
bull Detectores de alto voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se utilizan entre 1500 vol y 25000 vol
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3941
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm g 62-87
bull Detectores de alto voltaje para tuberias
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull
Se utilizan entre 1500 vol y 25000 volbull Los valores de prueba dependen de los
espesores del recubrimiento
Di t ib t d b
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4041
Distributed by
CONCLUSION
Para lograr un perfecto desempentildeo de unrecubrimiento debemos cubrir todas las fases delproceso de aplicacioacuten y seleccioacuten de forma integralEsto solo se lo ra con el total conocimiento or arte
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
de los involucrados de las teacutecnicas y caracteriacutesticasde los productos que usamos
Distributed by
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4141
Distributed by
Pinturas para mantenimiento
GRACIAS
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1541
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1641
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1741
Distributed by
MEDICION DE ESPESORES
bull Procedimiento
bull Realizar 3 mediciones en un areacutea inferior a 1
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Promediar estos 3 datos hay que tener encuenta que ninguna medicioacuten debe ser inferior
al 80 del espesor especificado
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1841
Distributed by
NUMERO DE MEDICIONES
bull
Si el aacuterea es menor a 92 m2 tomar 5 muestreos
bull Si el aacuterea esta entre 92 m2 y 276 m2 medir cada 92 m2de acuerdo al numeral anterior
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Areas hasta 92 m2 escoger tres zonas de acuerdo alprimer numeral
bull Si es mayor a 92 m2 los primeros 92 m2 como el numeralanterior por cada 92 m2 tomar seguacuten el primer numeral
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1941
Distributed by
PRUEBAS DE ADHERENCIA POR CINTA
bullldquoEstandar test methodos for measuring adhesion bytape testrdquo norma astm d 3359
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
el contratista
bull En sistemas multicapas esta prueba generalmente
no muestra la adhesioacuten sobre el sustrato
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2041
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2141
Distributed by
PARA ESPESORES ENTRE 0 Y 2 MILS
bull Realizar una cuadricula de 25 partes a 1 mm dedistancia
bull A licar la cinta de arla entre 1 2 minutos
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull Calificar de acuerdo a los cuadros despegados 0b si sedespego mas del 65 hsta 5b que equivale a uncomportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2241
Distributed by
PARA ESPESORES ENTRE 2 Y 5 MILS
bull
Realizar una cuadricula de 25 partes a 2 mm dedistancia
bull
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull
Calificar de acuerdo a los cuadros despegados 0b si sedespego mas del 65 hsta 5b que equivale a uncomportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2341
Distributed by
PARA ESPESORES MAYORES A 5 MILS
bull
Realizar un corte en x con un angulo entre 30 y 45grados
bull
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull
Calificar de acuerdo a los cuadros despegados 0a si sedespego el cuadrado correspondiente a la x hasta 5aque equivale a un comportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2441
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2541
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Se realiza mediante la aplicacioacuten unos probadores o
Pinturas de Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
especiales y midiendo la tensioacuten aplicada paradespegar los mismos
bull Es una prueba de acuerdo con el cliente y el aplicador
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2641
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
de la pelicula como la cantidad de recubrimientosdespegados en el dado
bull La presion de ruptura esta de acuerdo a lossistemas aplicados y a la preparacioacuten de superficie
hecha
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2741
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull Procedimiento seguacuten norma astm d4541
bull Criterios(Seguacuten norma ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull a preparac on e super c e es a gra o comerc a yla pintura es base amida la tension minima es 710 psi
bull Si la preparacion de superficie es a grado comercial yla pintura es base amina la tension minima es 400 psi
bull
Si es poliuretano sobre pinturas aminas o amidas latension minima es 280 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2841
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios(Seguacuten norma icontec ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Si la preparacion es manual-mecanica la medicioncalificara indirectamente la calidad de la preparacion desuperficie
bull Si la pintura es un esmalte alquidico se debe esperar 15dias y la presion minima debe ser 250 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2941
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3041
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3141
Distributed by
PERFIL DE ANCLAJE
bull
Es la distancia promedio entre los picos y losvalles generados por la preparacion desuperficie
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Es una prueba de acuerdo cliente-aplicador
bull Se recomienda entre el 10 y el 15 del
espesor del sistema que se va a aplicar
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3241
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3341
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3441
Distributed by
PERFIL DE ANCLAJE
bull Se mide copiando el perfil mediante plaacutesticosespeciales y llevaacutendolo a un microacutemetro
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3541
Distributed by
CONDICIONES AMBIENTALES
bull Norma astm e337
bull Temperatura de chapabull Debe ser superior minimo en 3degc a la temperatura decrocio
bull Tem eratura ambiental
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
La reaccion de una pintura epoxica se detiene a menos de4degc
bull Humedad relativa
bull Se mide mediante higrometros ninguna pintura epoxica o
base solvente debe ser aplicada si la humedad relativa essuperior al 85
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3641
Distributed by
DETECCION DE DISCONTINUIDADES
bull Norma astm d 5162-91
bull Detectores bajo voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la pelicula mediantela circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se usa generalmente un detector entre 6 y 50 voltiosde corriente directa
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3741
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3841
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm d 5162-91
bull Detectores de alto voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se utilizan entre 1500 vol y 25000 vol
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3941
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm g 62-87
bull Detectores de alto voltaje para tuberias
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull
Se utilizan entre 1500 vol y 25000 volbull Los valores de prueba dependen de los
espesores del recubrimiento
Di t ib t d b
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4041
Distributed by
CONCLUSION
Para lograr un perfecto desempentildeo de unrecubrimiento debemos cubrir todas las fases delproceso de aplicacioacuten y seleccioacuten de forma integralEsto solo se lo ra con el total conocimiento or arte
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
de los involucrados de las teacutecnicas y caracteriacutesticasde los productos que usamos
Distributed by
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4141
Distributed by
Pinturas para mantenimiento
GRACIAS
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1641
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1741
Distributed by
MEDICION DE ESPESORES
bull Procedimiento
bull Realizar 3 mediciones en un areacutea inferior a 1
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Promediar estos 3 datos hay que tener encuenta que ninguna medicioacuten debe ser inferior
al 80 del espesor especificado
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1841
Distributed by
NUMERO DE MEDICIONES
bull
Si el aacuterea es menor a 92 m2 tomar 5 muestreos
bull Si el aacuterea esta entre 92 m2 y 276 m2 medir cada 92 m2de acuerdo al numeral anterior
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Areas hasta 92 m2 escoger tres zonas de acuerdo alprimer numeral
bull Si es mayor a 92 m2 los primeros 92 m2 como el numeralanterior por cada 92 m2 tomar seguacuten el primer numeral
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1941
Distributed by
PRUEBAS DE ADHERENCIA POR CINTA
bullldquoEstandar test methodos for measuring adhesion bytape testrdquo norma astm d 3359
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
el contratista
bull En sistemas multicapas esta prueba generalmente
no muestra la adhesioacuten sobre el sustrato
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2041
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2141
Distributed by
PARA ESPESORES ENTRE 0 Y 2 MILS
bull Realizar una cuadricula de 25 partes a 1 mm dedistancia
bull A licar la cinta de arla entre 1 2 minutos
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull Calificar de acuerdo a los cuadros despegados 0b si sedespego mas del 65 hsta 5b que equivale a uncomportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2241
Distributed by
PARA ESPESORES ENTRE 2 Y 5 MILS
bull
Realizar una cuadricula de 25 partes a 2 mm dedistancia
bull
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull
Calificar de acuerdo a los cuadros despegados 0b si sedespego mas del 65 hsta 5b que equivale a uncomportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2341
Distributed by
PARA ESPESORES MAYORES A 5 MILS
bull
Realizar un corte en x con un angulo entre 30 y 45grados
bull
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull
Calificar de acuerdo a los cuadros despegados 0a si sedespego el cuadrado correspondiente a la x hasta 5aque equivale a un comportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2441
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2541
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Se realiza mediante la aplicacioacuten unos probadores o
Pinturas de Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
especiales y midiendo la tensioacuten aplicada paradespegar los mismos
bull Es una prueba de acuerdo con el cliente y el aplicador
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2641
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
de la pelicula como la cantidad de recubrimientosdespegados en el dado
bull La presion de ruptura esta de acuerdo a lossistemas aplicados y a la preparacioacuten de superficie
hecha
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2741
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull Procedimiento seguacuten norma astm d4541
bull Criterios(Seguacuten norma ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull a preparac on e super c e es a gra o comerc a yla pintura es base amida la tension minima es 710 psi
bull Si la preparacion de superficie es a grado comercial yla pintura es base amina la tension minima es 400 psi
bull
Si es poliuretano sobre pinturas aminas o amidas latension minima es 280 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2841
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios(Seguacuten norma icontec ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Si la preparacion es manual-mecanica la medicioncalificara indirectamente la calidad de la preparacion desuperficie
bull Si la pintura es un esmalte alquidico se debe esperar 15dias y la presion minima debe ser 250 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2941
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3041
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3141
Distributed by
PERFIL DE ANCLAJE
bull
Es la distancia promedio entre los picos y losvalles generados por la preparacion desuperficie
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Es una prueba de acuerdo cliente-aplicador
bull Se recomienda entre el 10 y el 15 del
espesor del sistema que se va a aplicar
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3241
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3341
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3441
Distributed by
PERFIL DE ANCLAJE
bull Se mide copiando el perfil mediante plaacutesticosespeciales y llevaacutendolo a un microacutemetro
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3541
Distributed by
CONDICIONES AMBIENTALES
bull Norma astm e337
bull Temperatura de chapabull Debe ser superior minimo en 3degc a la temperatura decrocio
bull Tem eratura ambiental
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
La reaccion de una pintura epoxica se detiene a menos de4degc
bull Humedad relativa
bull Se mide mediante higrometros ninguna pintura epoxica o
base solvente debe ser aplicada si la humedad relativa essuperior al 85
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3641
Distributed by
DETECCION DE DISCONTINUIDADES
bull Norma astm d 5162-91
bull Detectores bajo voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la pelicula mediantela circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se usa generalmente un detector entre 6 y 50 voltiosde corriente directa
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3741
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3841
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm d 5162-91
bull Detectores de alto voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se utilizan entre 1500 vol y 25000 vol
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3941
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm g 62-87
bull Detectores de alto voltaje para tuberias
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull
Se utilizan entre 1500 vol y 25000 volbull Los valores de prueba dependen de los
espesores del recubrimiento
Di t ib t d b
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4041
Distributed by
CONCLUSION
Para lograr un perfecto desempentildeo de unrecubrimiento debemos cubrir todas las fases delproceso de aplicacioacuten y seleccioacuten de forma integralEsto solo se lo ra con el total conocimiento or arte
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
de los involucrados de las teacutecnicas y caracteriacutesticasde los productos que usamos
Distributed by
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4141
Distributed by
Pinturas para mantenimiento
GRACIAS
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1741
Distributed by
MEDICION DE ESPESORES
bull Procedimiento
bull Realizar 3 mediciones en un areacutea inferior a 1
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Promediar estos 3 datos hay que tener encuenta que ninguna medicioacuten debe ser inferior
al 80 del espesor especificado
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1841
Distributed by
NUMERO DE MEDICIONES
bull
Si el aacuterea es menor a 92 m2 tomar 5 muestreos
bull Si el aacuterea esta entre 92 m2 y 276 m2 medir cada 92 m2de acuerdo al numeral anterior
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Areas hasta 92 m2 escoger tres zonas de acuerdo alprimer numeral
bull Si es mayor a 92 m2 los primeros 92 m2 como el numeralanterior por cada 92 m2 tomar seguacuten el primer numeral
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1941
Distributed by
PRUEBAS DE ADHERENCIA POR CINTA
bullldquoEstandar test methodos for measuring adhesion bytape testrdquo norma astm d 3359
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
el contratista
bull En sistemas multicapas esta prueba generalmente
no muestra la adhesioacuten sobre el sustrato
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2041
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2141
Distributed by
PARA ESPESORES ENTRE 0 Y 2 MILS
bull Realizar una cuadricula de 25 partes a 1 mm dedistancia
bull A licar la cinta de arla entre 1 2 minutos
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull Calificar de acuerdo a los cuadros despegados 0b si sedespego mas del 65 hsta 5b que equivale a uncomportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2241
Distributed by
PARA ESPESORES ENTRE 2 Y 5 MILS
bull
Realizar una cuadricula de 25 partes a 2 mm dedistancia
bull
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull
Calificar de acuerdo a los cuadros despegados 0b si sedespego mas del 65 hsta 5b que equivale a uncomportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2341
Distributed by
PARA ESPESORES MAYORES A 5 MILS
bull
Realizar un corte en x con un angulo entre 30 y 45grados
bull
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull
Calificar de acuerdo a los cuadros despegados 0a si sedespego el cuadrado correspondiente a la x hasta 5aque equivale a un comportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2441
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2541
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Se realiza mediante la aplicacioacuten unos probadores o
Pinturas de Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
especiales y midiendo la tensioacuten aplicada paradespegar los mismos
bull Es una prueba de acuerdo con el cliente y el aplicador
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2641
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
de la pelicula como la cantidad de recubrimientosdespegados en el dado
bull La presion de ruptura esta de acuerdo a lossistemas aplicados y a la preparacioacuten de superficie
hecha
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2741
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull Procedimiento seguacuten norma astm d4541
bull Criterios(Seguacuten norma ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull a preparac on e super c e es a gra o comerc a yla pintura es base amida la tension minima es 710 psi
bull Si la preparacion de superficie es a grado comercial yla pintura es base amina la tension minima es 400 psi
bull
Si es poliuretano sobre pinturas aminas o amidas latension minima es 280 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2841
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios(Seguacuten norma icontec ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Si la preparacion es manual-mecanica la medicioncalificara indirectamente la calidad de la preparacion desuperficie
bull Si la pintura es un esmalte alquidico se debe esperar 15dias y la presion minima debe ser 250 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2941
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3041
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3141
Distributed by
PERFIL DE ANCLAJE
bull
Es la distancia promedio entre los picos y losvalles generados por la preparacion desuperficie
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Es una prueba de acuerdo cliente-aplicador
bull Se recomienda entre el 10 y el 15 del
espesor del sistema que se va a aplicar
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3241
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3341
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3441
Distributed by
PERFIL DE ANCLAJE
bull Se mide copiando el perfil mediante plaacutesticosespeciales y llevaacutendolo a un microacutemetro
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3541
Distributed by
CONDICIONES AMBIENTALES
bull Norma astm e337
bull Temperatura de chapabull Debe ser superior minimo en 3degc a la temperatura decrocio
bull Tem eratura ambiental
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
La reaccion de una pintura epoxica se detiene a menos de4degc
bull Humedad relativa
bull Se mide mediante higrometros ninguna pintura epoxica o
base solvente debe ser aplicada si la humedad relativa essuperior al 85
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3641
Distributed by
DETECCION DE DISCONTINUIDADES
bull Norma astm d 5162-91
bull Detectores bajo voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la pelicula mediantela circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se usa generalmente un detector entre 6 y 50 voltiosde corriente directa
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3741
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3841
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm d 5162-91
bull Detectores de alto voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se utilizan entre 1500 vol y 25000 vol
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3941
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm g 62-87
bull Detectores de alto voltaje para tuberias
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull
Se utilizan entre 1500 vol y 25000 volbull Los valores de prueba dependen de los
espesores del recubrimiento
Di t ib t d b
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4041
Distributed by
CONCLUSION
Para lograr un perfecto desempentildeo de unrecubrimiento debemos cubrir todas las fases delproceso de aplicacioacuten y seleccioacuten de forma integralEsto solo se lo ra con el total conocimiento or arte
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
de los involucrados de las teacutecnicas y caracteriacutesticasde los productos que usamos
Distributed by
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4141
Distributed by
Pinturas para mantenimiento
GRACIAS
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1841
Distributed by
NUMERO DE MEDICIONES
bull
Si el aacuterea es menor a 92 m2 tomar 5 muestreos
bull Si el aacuterea esta entre 92 m2 y 276 m2 medir cada 92 m2de acuerdo al numeral anterior
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Areas hasta 92 m2 escoger tres zonas de acuerdo alprimer numeral
bull Si es mayor a 92 m2 los primeros 92 m2 como el numeralanterior por cada 92 m2 tomar seguacuten el primer numeral
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1941
Distributed by
PRUEBAS DE ADHERENCIA POR CINTA
bullldquoEstandar test methodos for measuring adhesion bytape testrdquo norma astm d 3359
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
el contratista
bull En sistemas multicapas esta prueba generalmente
no muestra la adhesioacuten sobre el sustrato
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2041
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2141
Distributed by
PARA ESPESORES ENTRE 0 Y 2 MILS
bull Realizar una cuadricula de 25 partes a 1 mm dedistancia
bull A licar la cinta de arla entre 1 2 minutos
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull Calificar de acuerdo a los cuadros despegados 0b si sedespego mas del 65 hsta 5b que equivale a uncomportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2241
Distributed by
PARA ESPESORES ENTRE 2 Y 5 MILS
bull
Realizar una cuadricula de 25 partes a 2 mm dedistancia
bull
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull
Calificar de acuerdo a los cuadros despegados 0b si sedespego mas del 65 hsta 5b que equivale a uncomportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2341
Distributed by
PARA ESPESORES MAYORES A 5 MILS
bull
Realizar un corte en x con un angulo entre 30 y 45grados
bull
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull
Calificar de acuerdo a los cuadros despegados 0a si sedespego el cuadrado correspondiente a la x hasta 5aque equivale a un comportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2441
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2541
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Se realiza mediante la aplicacioacuten unos probadores o
Pinturas de Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
especiales y midiendo la tensioacuten aplicada paradespegar los mismos
bull Es una prueba de acuerdo con el cliente y el aplicador
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2641
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
de la pelicula como la cantidad de recubrimientosdespegados en el dado
bull La presion de ruptura esta de acuerdo a lossistemas aplicados y a la preparacioacuten de superficie
hecha
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2741
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull Procedimiento seguacuten norma astm d4541
bull Criterios(Seguacuten norma ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull a preparac on e super c e es a gra o comerc a yla pintura es base amida la tension minima es 710 psi
bull Si la preparacion de superficie es a grado comercial yla pintura es base amina la tension minima es 400 psi
bull
Si es poliuretano sobre pinturas aminas o amidas latension minima es 280 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2841
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios(Seguacuten norma icontec ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Si la preparacion es manual-mecanica la medicioncalificara indirectamente la calidad de la preparacion desuperficie
bull Si la pintura es un esmalte alquidico se debe esperar 15dias y la presion minima debe ser 250 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2941
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3041
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3141
Distributed by
PERFIL DE ANCLAJE
bull
Es la distancia promedio entre los picos y losvalles generados por la preparacion desuperficie
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Es una prueba de acuerdo cliente-aplicador
bull Se recomienda entre el 10 y el 15 del
espesor del sistema que se va a aplicar
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3241
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3341
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3441
Distributed by
PERFIL DE ANCLAJE
bull Se mide copiando el perfil mediante plaacutesticosespeciales y llevaacutendolo a un microacutemetro
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3541
Distributed by
CONDICIONES AMBIENTALES
bull Norma astm e337
bull Temperatura de chapabull Debe ser superior minimo en 3degc a la temperatura decrocio
bull Tem eratura ambiental
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
La reaccion de una pintura epoxica se detiene a menos de4degc
bull Humedad relativa
bull Se mide mediante higrometros ninguna pintura epoxica o
base solvente debe ser aplicada si la humedad relativa essuperior al 85
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3641
Distributed by
DETECCION DE DISCONTINUIDADES
bull Norma astm d 5162-91
bull Detectores bajo voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la pelicula mediantela circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se usa generalmente un detector entre 6 y 50 voltiosde corriente directa
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3741
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3841
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm d 5162-91
bull Detectores de alto voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se utilizan entre 1500 vol y 25000 vol
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3941
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm g 62-87
bull Detectores de alto voltaje para tuberias
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull
Se utilizan entre 1500 vol y 25000 volbull Los valores de prueba dependen de los
espesores del recubrimiento
Di t ib t d b
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4041
Distributed by
CONCLUSION
Para lograr un perfecto desempentildeo de unrecubrimiento debemos cubrir todas las fases delproceso de aplicacioacuten y seleccioacuten de forma integralEsto solo se lo ra con el total conocimiento or arte
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
de los involucrados de las teacutecnicas y caracteriacutesticasde los productos que usamos
Distributed by
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4141
Distributed by
Pinturas para mantenimiento
GRACIAS
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 1941
Distributed by
PRUEBAS DE ADHERENCIA POR CINTA
bullldquoEstandar test methodos for measuring adhesion bytape testrdquo norma astm d 3359
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
el contratista
bull En sistemas multicapas esta prueba generalmente
no muestra la adhesioacuten sobre el sustrato
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2041
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2141
Distributed by
PARA ESPESORES ENTRE 0 Y 2 MILS
bull Realizar una cuadricula de 25 partes a 1 mm dedistancia
bull A licar la cinta de arla entre 1 2 minutos
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull Calificar de acuerdo a los cuadros despegados 0b si sedespego mas del 65 hsta 5b que equivale a uncomportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2241
Distributed by
PARA ESPESORES ENTRE 2 Y 5 MILS
bull
Realizar una cuadricula de 25 partes a 2 mm dedistancia
bull
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull
Calificar de acuerdo a los cuadros despegados 0b si sedespego mas del 65 hsta 5b que equivale a uncomportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2341
Distributed by
PARA ESPESORES MAYORES A 5 MILS
bull
Realizar un corte en x con un angulo entre 30 y 45grados
bull
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull
Calificar de acuerdo a los cuadros despegados 0a si sedespego el cuadrado correspondiente a la x hasta 5aque equivale a un comportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2441
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2541
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Se realiza mediante la aplicacioacuten unos probadores o
Pinturas de Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
especiales y midiendo la tensioacuten aplicada paradespegar los mismos
bull Es una prueba de acuerdo con el cliente y el aplicador
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2641
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
de la pelicula como la cantidad de recubrimientosdespegados en el dado
bull La presion de ruptura esta de acuerdo a lossistemas aplicados y a la preparacioacuten de superficie
hecha
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2741
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull Procedimiento seguacuten norma astm d4541
bull Criterios(Seguacuten norma ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull a preparac on e super c e es a gra o comerc a yla pintura es base amida la tension minima es 710 psi
bull Si la preparacion de superficie es a grado comercial yla pintura es base amina la tension minima es 400 psi
bull
Si es poliuretano sobre pinturas aminas o amidas latension minima es 280 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2841
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios(Seguacuten norma icontec ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Si la preparacion es manual-mecanica la medicioncalificara indirectamente la calidad de la preparacion desuperficie
bull Si la pintura es un esmalte alquidico se debe esperar 15dias y la presion minima debe ser 250 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2941
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3041
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3141
Distributed by
PERFIL DE ANCLAJE
bull
Es la distancia promedio entre los picos y losvalles generados por la preparacion desuperficie
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Es una prueba de acuerdo cliente-aplicador
bull Se recomienda entre el 10 y el 15 del
espesor del sistema que se va a aplicar
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3241
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3341
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3441
Distributed by
PERFIL DE ANCLAJE
bull Se mide copiando el perfil mediante plaacutesticosespeciales y llevaacutendolo a un microacutemetro
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3541
Distributed by
CONDICIONES AMBIENTALES
bull Norma astm e337
bull Temperatura de chapabull Debe ser superior minimo en 3degc a la temperatura decrocio
bull Tem eratura ambiental
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
La reaccion de una pintura epoxica se detiene a menos de4degc
bull Humedad relativa
bull Se mide mediante higrometros ninguna pintura epoxica o
base solvente debe ser aplicada si la humedad relativa essuperior al 85
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3641
Distributed by
DETECCION DE DISCONTINUIDADES
bull Norma astm d 5162-91
bull Detectores bajo voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la pelicula mediantela circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se usa generalmente un detector entre 6 y 50 voltiosde corriente directa
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3741
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3841
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm d 5162-91
bull Detectores de alto voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se utilizan entre 1500 vol y 25000 vol
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3941
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm g 62-87
bull Detectores de alto voltaje para tuberias
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull
Se utilizan entre 1500 vol y 25000 volbull Los valores de prueba dependen de los
espesores del recubrimiento
Di t ib t d b
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4041
Distributed by
CONCLUSION
Para lograr un perfecto desempentildeo de unrecubrimiento debemos cubrir todas las fases delproceso de aplicacioacuten y seleccioacuten de forma integralEsto solo se lo ra con el total conocimiento or arte
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
de los involucrados de las teacutecnicas y caracteriacutesticasde los productos que usamos
Distributed by
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4141
Distributed by
Pinturas para mantenimiento
GRACIAS
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2041
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2141
Distributed by
PARA ESPESORES ENTRE 0 Y 2 MILS
bull Realizar una cuadricula de 25 partes a 1 mm dedistancia
bull A licar la cinta de arla entre 1 2 minutos
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull Calificar de acuerdo a los cuadros despegados 0b si sedespego mas del 65 hsta 5b que equivale a uncomportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2241
Distributed by
PARA ESPESORES ENTRE 2 Y 5 MILS
bull
Realizar una cuadricula de 25 partes a 2 mm dedistancia
bull
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull
Calificar de acuerdo a los cuadros despegados 0b si sedespego mas del 65 hsta 5b que equivale a uncomportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2341
Distributed by
PARA ESPESORES MAYORES A 5 MILS
bull
Realizar un corte en x con un angulo entre 30 y 45grados
bull
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull
Calificar de acuerdo a los cuadros despegados 0a si sedespego el cuadrado correspondiente a la x hasta 5aque equivale a un comportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2441
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2541
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Se realiza mediante la aplicacioacuten unos probadores o
Pinturas de Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
especiales y midiendo la tensioacuten aplicada paradespegar los mismos
bull Es una prueba de acuerdo con el cliente y el aplicador
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2641
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
de la pelicula como la cantidad de recubrimientosdespegados en el dado
bull La presion de ruptura esta de acuerdo a lossistemas aplicados y a la preparacioacuten de superficie
hecha
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2741
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull Procedimiento seguacuten norma astm d4541
bull Criterios(Seguacuten norma ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull a preparac on e super c e es a gra o comerc a yla pintura es base amida la tension minima es 710 psi
bull Si la preparacion de superficie es a grado comercial yla pintura es base amina la tension minima es 400 psi
bull
Si es poliuretano sobre pinturas aminas o amidas latension minima es 280 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2841
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios(Seguacuten norma icontec ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Si la preparacion es manual-mecanica la medicioncalificara indirectamente la calidad de la preparacion desuperficie
bull Si la pintura es un esmalte alquidico se debe esperar 15dias y la presion minima debe ser 250 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2941
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3041
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3141
Distributed by
PERFIL DE ANCLAJE
bull
Es la distancia promedio entre los picos y losvalles generados por la preparacion desuperficie
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Es una prueba de acuerdo cliente-aplicador
bull Se recomienda entre el 10 y el 15 del
espesor del sistema que se va a aplicar
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3241
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3341
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3441
Distributed by
PERFIL DE ANCLAJE
bull Se mide copiando el perfil mediante plaacutesticosespeciales y llevaacutendolo a un microacutemetro
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3541
Distributed by
CONDICIONES AMBIENTALES
bull Norma astm e337
bull Temperatura de chapabull Debe ser superior minimo en 3degc a la temperatura decrocio
bull Tem eratura ambiental
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
La reaccion de una pintura epoxica se detiene a menos de4degc
bull Humedad relativa
bull Se mide mediante higrometros ninguna pintura epoxica o
base solvente debe ser aplicada si la humedad relativa essuperior al 85
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3641
Distributed by
DETECCION DE DISCONTINUIDADES
bull Norma astm d 5162-91
bull Detectores bajo voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la pelicula mediantela circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se usa generalmente un detector entre 6 y 50 voltiosde corriente directa
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3741
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3841
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm d 5162-91
bull Detectores de alto voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se utilizan entre 1500 vol y 25000 vol
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3941
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm g 62-87
bull Detectores de alto voltaje para tuberias
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull
Se utilizan entre 1500 vol y 25000 volbull Los valores de prueba dependen de los
espesores del recubrimiento
Di t ib t d b
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4041
Distributed by
CONCLUSION
Para lograr un perfecto desempentildeo de unrecubrimiento debemos cubrir todas las fases delproceso de aplicacioacuten y seleccioacuten de forma integralEsto solo se lo ra con el total conocimiento or arte
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
de los involucrados de las teacutecnicas y caracteriacutesticasde los productos que usamos
Distributed by
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4141
Distributed by
Pinturas para mantenimiento
GRACIAS
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2141
Distributed by
PARA ESPESORES ENTRE 0 Y 2 MILS
bull Realizar una cuadricula de 25 partes a 1 mm dedistancia
bull A licar la cinta de arla entre 1 2 minutos
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull Calificar de acuerdo a los cuadros despegados 0b si sedespego mas del 65 hsta 5b que equivale a uncomportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2241
Distributed by
PARA ESPESORES ENTRE 2 Y 5 MILS
bull
Realizar una cuadricula de 25 partes a 2 mm dedistancia
bull
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull
Calificar de acuerdo a los cuadros despegados 0b si sedespego mas del 65 hsta 5b que equivale a uncomportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2341
Distributed by
PARA ESPESORES MAYORES A 5 MILS
bull
Realizar un corte en x con un angulo entre 30 y 45grados
bull
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull
Calificar de acuerdo a los cuadros despegados 0a si sedespego el cuadrado correspondiente a la x hasta 5aque equivale a un comportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2441
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2541
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Se realiza mediante la aplicacioacuten unos probadores o
Pinturas de Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
especiales y midiendo la tensioacuten aplicada paradespegar los mismos
bull Es una prueba de acuerdo con el cliente y el aplicador
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2641
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
de la pelicula como la cantidad de recubrimientosdespegados en el dado
bull La presion de ruptura esta de acuerdo a lossistemas aplicados y a la preparacioacuten de superficie
hecha
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2741
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull Procedimiento seguacuten norma astm d4541
bull Criterios(Seguacuten norma ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull a preparac on e super c e es a gra o comerc a yla pintura es base amida la tension minima es 710 psi
bull Si la preparacion de superficie es a grado comercial yla pintura es base amina la tension minima es 400 psi
bull
Si es poliuretano sobre pinturas aminas o amidas latension minima es 280 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2841
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios(Seguacuten norma icontec ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Si la preparacion es manual-mecanica la medicioncalificara indirectamente la calidad de la preparacion desuperficie
bull Si la pintura es un esmalte alquidico se debe esperar 15dias y la presion minima debe ser 250 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2941
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3041
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3141
Distributed by
PERFIL DE ANCLAJE
bull
Es la distancia promedio entre los picos y losvalles generados por la preparacion desuperficie
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Es una prueba de acuerdo cliente-aplicador
bull Se recomienda entre el 10 y el 15 del
espesor del sistema que se va a aplicar
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3241
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3341
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3441
Distributed by
PERFIL DE ANCLAJE
bull Se mide copiando el perfil mediante plaacutesticosespeciales y llevaacutendolo a un microacutemetro
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3541
Distributed by
CONDICIONES AMBIENTALES
bull Norma astm e337
bull Temperatura de chapabull Debe ser superior minimo en 3degc a la temperatura decrocio
bull Tem eratura ambiental
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
La reaccion de una pintura epoxica se detiene a menos de4degc
bull Humedad relativa
bull Se mide mediante higrometros ninguna pintura epoxica o
base solvente debe ser aplicada si la humedad relativa essuperior al 85
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3641
Distributed by
DETECCION DE DISCONTINUIDADES
bull Norma astm d 5162-91
bull Detectores bajo voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la pelicula mediantela circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se usa generalmente un detector entre 6 y 50 voltiosde corriente directa
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3741
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3841
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm d 5162-91
bull Detectores de alto voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se utilizan entre 1500 vol y 25000 vol
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3941
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm g 62-87
bull Detectores de alto voltaje para tuberias
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull
Se utilizan entre 1500 vol y 25000 volbull Los valores de prueba dependen de los
espesores del recubrimiento
Di t ib t d b
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4041
Distributed by
CONCLUSION
Para lograr un perfecto desempentildeo de unrecubrimiento debemos cubrir todas las fases delproceso de aplicacioacuten y seleccioacuten de forma integralEsto solo se lo ra con el total conocimiento or arte
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
de los involucrados de las teacutecnicas y caracteriacutesticasde los productos que usamos
Distributed by
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4141
Distributed by
Pinturas para mantenimiento
GRACIAS
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2241
Distributed by
PARA ESPESORES ENTRE 2 Y 5 MILS
bull
Realizar una cuadricula de 25 partes a 2 mm dedistancia
bull
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull
Calificar de acuerdo a los cuadros despegados 0b si sedespego mas del 65 hsta 5b que equivale a uncomportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2341
Distributed by
PARA ESPESORES MAYORES A 5 MILS
bull
Realizar un corte en x con un angulo entre 30 y 45grados
bull
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull
Calificar de acuerdo a los cuadros despegados 0a si sedespego el cuadrado correspondiente a la x hasta 5aque equivale a un comportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2441
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2541
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Se realiza mediante la aplicacioacuten unos probadores o
Pinturas de Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
especiales y midiendo la tensioacuten aplicada paradespegar los mismos
bull Es una prueba de acuerdo con el cliente y el aplicador
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2641
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
de la pelicula como la cantidad de recubrimientosdespegados en el dado
bull La presion de ruptura esta de acuerdo a lossistemas aplicados y a la preparacioacuten de superficie
hecha
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2741
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull Procedimiento seguacuten norma astm d4541
bull Criterios(Seguacuten norma ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull a preparac on e super c e es a gra o comerc a yla pintura es base amida la tension minima es 710 psi
bull Si la preparacion de superficie es a grado comercial yla pintura es base amina la tension minima es 400 psi
bull
Si es poliuretano sobre pinturas aminas o amidas latension minima es 280 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2841
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios(Seguacuten norma icontec ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Si la preparacion es manual-mecanica la medicioncalificara indirectamente la calidad de la preparacion desuperficie
bull Si la pintura es un esmalte alquidico se debe esperar 15dias y la presion minima debe ser 250 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2941
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3041
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3141
Distributed by
PERFIL DE ANCLAJE
bull
Es la distancia promedio entre los picos y losvalles generados por la preparacion desuperficie
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Es una prueba de acuerdo cliente-aplicador
bull Se recomienda entre el 10 y el 15 del
espesor del sistema que se va a aplicar
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3241
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3341
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3441
Distributed by
PERFIL DE ANCLAJE
bull Se mide copiando el perfil mediante plaacutesticosespeciales y llevaacutendolo a un microacutemetro
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3541
Distributed by
CONDICIONES AMBIENTALES
bull Norma astm e337
bull Temperatura de chapabull Debe ser superior minimo en 3degc a la temperatura decrocio
bull Tem eratura ambiental
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
La reaccion de una pintura epoxica se detiene a menos de4degc
bull Humedad relativa
bull Se mide mediante higrometros ninguna pintura epoxica o
base solvente debe ser aplicada si la humedad relativa essuperior al 85
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3641
Distributed by
DETECCION DE DISCONTINUIDADES
bull Norma astm d 5162-91
bull Detectores bajo voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la pelicula mediantela circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se usa generalmente un detector entre 6 y 50 voltiosde corriente directa
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3741
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3841
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm d 5162-91
bull Detectores de alto voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se utilizan entre 1500 vol y 25000 vol
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3941
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm g 62-87
bull Detectores de alto voltaje para tuberias
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull
Se utilizan entre 1500 vol y 25000 volbull Los valores de prueba dependen de los
espesores del recubrimiento
Di t ib t d b
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4041
Distributed by
CONCLUSION
Para lograr un perfecto desempentildeo de unrecubrimiento debemos cubrir todas las fases delproceso de aplicacioacuten y seleccioacuten de forma integralEsto solo se lo ra con el total conocimiento or arte
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
de los involucrados de las teacutecnicas y caracteriacutesticasde los productos que usamos
Distributed by
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4141
Distributed by
Pinturas para mantenimiento
GRACIAS
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2341
Distributed by
PARA ESPESORES MAYORES A 5 MILS
bull
Realizar un corte en x con un angulo entre 30 y 45grados
bull
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Levantar la cinta fuertemente
bull
Calificar de acuerdo a los cuadros despegados 0a si sedespego el cuadrado correspondiente a la x hasta 5aque equivale a un comportamiento optimo
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2441
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2541
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Se realiza mediante la aplicacioacuten unos probadores o
Pinturas de Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
especiales y midiendo la tensioacuten aplicada paradespegar los mismos
bull Es una prueba de acuerdo con el cliente y el aplicador
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2641
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
de la pelicula como la cantidad de recubrimientosdespegados en el dado
bull La presion de ruptura esta de acuerdo a lossistemas aplicados y a la preparacioacuten de superficie
hecha
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2741
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull Procedimiento seguacuten norma astm d4541
bull Criterios(Seguacuten norma ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull a preparac on e super c e es a gra o comerc a yla pintura es base amida la tension minima es 710 psi
bull Si la preparacion de superficie es a grado comercial yla pintura es base amina la tension minima es 400 psi
bull
Si es poliuretano sobre pinturas aminas o amidas latension minima es 280 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2841
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios(Seguacuten norma icontec ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Si la preparacion es manual-mecanica la medicioncalificara indirectamente la calidad de la preparacion desuperficie
bull Si la pintura es un esmalte alquidico se debe esperar 15dias y la presion minima debe ser 250 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2941
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3041
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3141
Distributed by
PERFIL DE ANCLAJE
bull
Es la distancia promedio entre los picos y losvalles generados por la preparacion desuperficie
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Es una prueba de acuerdo cliente-aplicador
bull Se recomienda entre el 10 y el 15 del
espesor del sistema que se va a aplicar
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3241
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3341
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3441
Distributed by
PERFIL DE ANCLAJE
bull Se mide copiando el perfil mediante plaacutesticosespeciales y llevaacutendolo a un microacutemetro
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3541
Distributed by
CONDICIONES AMBIENTALES
bull Norma astm e337
bull Temperatura de chapabull Debe ser superior minimo en 3degc a la temperatura decrocio
bull Tem eratura ambiental
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
La reaccion de una pintura epoxica se detiene a menos de4degc
bull Humedad relativa
bull Se mide mediante higrometros ninguna pintura epoxica o
base solvente debe ser aplicada si la humedad relativa essuperior al 85
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3641
Distributed by
DETECCION DE DISCONTINUIDADES
bull Norma astm d 5162-91
bull Detectores bajo voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la pelicula mediantela circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se usa generalmente un detector entre 6 y 50 voltiosde corriente directa
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3741
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3841
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm d 5162-91
bull Detectores de alto voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se utilizan entre 1500 vol y 25000 vol
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3941
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm g 62-87
bull Detectores de alto voltaje para tuberias
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull
Se utilizan entre 1500 vol y 25000 volbull Los valores de prueba dependen de los
espesores del recubrimiento
Di t ib t d b
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4041
Distributed by
CONCLUSION
Para lograr un perfecto desempentildeo de unrecubrimiento debemos cubrir todas las fases delproceso de aplicacioacuten y seleccioacuten de forma integralEsto solo se lo ra con el total conocimiento or arte
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
de los involucrados de las teacutecnicas y caracteriacutesticasde los productos que usamos
Distributed by
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4141
Distributed by
Pinturas para mantenimiento
GRACIAS
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2441
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2541
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Se realiza mediante la aplicacioacuten unos probadores o
Pinturas de Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
especiales y midiendo la tensioacuten aplicada paradespegar los mismos
bull Es una prueba de acuerdo con el cliente y el aplicador
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2641
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
de la pelicula como la cantidad de recubrimientosdespegados en el dado
bull La presion de ruptura esta de acuerdo a lossistemas aplicados y a la preparacioacuten de superficie
hecha
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2741
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull Procedimiento seguacuten norma astm d4541
bull Criterios(Seguacuten norma ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull a preparac on e super c e es a gra o comerc a yla pintura es base amida la tension minima es 710 psi
bull Si la preparacion de superficie es a grado comercial yla pintura es base amina la tension minima es 400 psi
bull
Si es poliuretano sobre pinturas aminas o amidas latension minima es 280 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2841
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios(Seguacuten norma icontec ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Si la preparacion es manual-mecanica la medicioncalificara indirectamente la calidad de la preparacion desuperficie
bull Si la pintura es un esmalte alquidico se debe esperar 15dias y la presion minima debe ser 250 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2941
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3041
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3141
Distributed by
PERFIL DE ANCLAJE
bull
Es la distancia promedio entre los picos y losvalles generados por la preparacion desuperficie
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Es una prueba de acuerdo cliente-aplicador
bull Se recomienda entre el 10 y el 15 del
espesor del sistema que se va a aplicar
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3241
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3341
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3441
Distributed by
PERFIL DE ANCLAJE
bull Se mide copiando el perfil mediante plaacutesticosespeciales y llevaacutendolo a un microacutemetro
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3541
Distributed by
CONDICIONES AMBIENTALES
bull Norma astm e337
bull Temperatura de chapabull Debe ser superior minimo en 3degc a la temperatura decrocio
bull Tem eratura ambiental
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
La reaccion de una pintura epoxica se detiene a menos de4degc
bull Humedad relativa
bull Se mide mediante higrometros ninguna pintura epoxica o
base solvente debe ser aplicada si la humedad relativa essuperior al 85
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3641
Distributed by
DETECCION DE DISCONTINUIDADES
bull Norma astm d 5162-91
bull Detectores bajo voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la pelicula mediantela circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se usa generalmente un detector entre 6 y 50 voltiosde corriente directa
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3741
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3841
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm d 5162-91
bull Detectores de alto voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se utilizan entre 1500 vol y 25000 vol
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3941
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm g 62-87
bull Detectores de alto voltaje para tuberias
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull
Se utilizan entre 1500 vol y 25000 volbull Los valores de prueba dependen de los
espesores del recubrimiento
Di t ib t d b
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4041
Distributed by
CONCLUSION
Para lograr un perfecto desempentildeo de unrecubrimiento debemos cubrir todas las fases delproceso de aplicacioacuten y seleccioacuten de forma integralEsto solo se lo ra con el total conocimiento or arte
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
de los involucrados de las teacutecnicas y caracteriacutesticasde los productos que usamos
Distributed by
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4141
Distributed by
Pinturas para mantenimiento
GRACIAS
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2541
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Se realiza mediante la aplicacioacuten unos probadores o
Pinturas de Mantenimiento
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
especiales y midiendo la tensioacuten aplicada paradespegar los mismos
bull Es una prueba de acuerdo con el cliente y el aplicador
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2641
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
de la pelicula como la cantidad de recubrimientosdespegados en el dado
bull La presion de ruptura esta de acuerdo a lossistemas aplicados y a la preparacioacuten de superficie
hecha
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2741
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull Procedimiento seguacuten norma astm d4541
bull Criterios(Seguacuten norma ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull a preparac on e super c e es a gra o comerc a yla pintura es base amida la tension minima es 710 psi
bull Si la preparacion de superficie es a grado comercial yla pintura es base amina la tension minima es 400 psi
bull
Si es poliuretano sobre pinturas aminas o amidas latension minima es 280 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2841
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios(Seguacuten norma icontec ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Si la preparacion es manual-mecanica la medicioncalificara indirectamente la calidad de la preparacion desuperficie
bull Si la pintura es un esmalte alquidico se debe esperar 15dias y la presion minima debe ser 250 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2941
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3041
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3141
Distributed by
PERFIL DE ANCLAJE
bull
Es la distancia promedio entre los picos y losvalles generados por la preparacion desuperficie
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Es una prueba de acuerdo cliente-aplicador
bull Se recomienda entre el 10 y el 15 del
espesor del sistema que se va a aplicar
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3241
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3341
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3441
Distributed by
PERFIL DE ANCLAJE
bull Se mide copiando el perfil mediante plaacutesticosespeciales y llevaacutendolo a un microacutemetro
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3541
Distributed by
CONDICIONES AMBIENTALES
bull Norma astm e337
bull Temperatura de chapabull Debe ser superior minimo en 3degc a la temperatura decrocio
bull Tem eratura ambiental
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
La reaccion de una pintura epoxica se detiene a menos de4degc
bull Humedad relativa
bull Se mide mediante higrometros ninguna pintura epoxica o
base solvente debe ser aplicada si la humedad relativa essuperior al 85
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3641
Distributed by
DETECCION DE DISCONTINUIDADES
bull Norma astm d 5162-91
bull Detectores bajo voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la pelicula mediantela circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se usa generalmente un detector entre 6 y 50 voltiosde corriente directa
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3741
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3841
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm d 5162-91
bull Detectores de alto voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se utilizan entre 1500 vol y 25000 vol
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3941
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm g 62-87
bull Detectores de alto voltaje para tuberias
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull
Se utilizan entre 1500 vol y 25000 volbull Los valores de prueba dependen de los
espesores del recubrimiento
Di t ib t d b
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4041
Distributed by
CONCLUSION
Para lograr un perfecto desempentildeo de unrecubrimiento debemos cubrir todas las fases delproceso de aplicacioacuten y seleccioacuten de forma integralEsto solo se lo ra con el total conocimiento or arte
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
de los involucrados de las teacutecnicas y caracteriacutesticasde los productos que usamos
Distributed by
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4141
Distributed by
Pinturas para mantenimiento
GRACIAS
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2641
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
de la pelicula como la cantidad de recubrimientosdespegados en el dado
bull La presion de ruptura esta de acuerdo a lossistemas aplicados y a la preparacioacuten de superficie
hecha
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2741
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull Procedimiento seguacuten norma astm d4541
bull Criterios(Seguacuten norma ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull a preparac on e super c e es a gra o comerc a yla pintura es base amida la tension minima es 710 psi
bull Si la preparacion de superficie es a grado comercial yla pintura es base amina la tension minima es 400 psi
bull
Si es poliuretano sobre pinturas aminas o amidas latension minima es 280 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2841
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios(Seguacuten norma icontec ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Si la preparacion es manual-mecanica la medicioncalificara indirectamente la calidad de la preparacion desuperficie
bull Si la pintura es un esmalte alquidico se debe esperar 15dias y la presion minima debe ser 250 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2941
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3041
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3141
Distributed by
PERFIL DE ANCLAJE
bull
Es la distancia promedio entre los picos y losvalles generados por la preparacion desuperficie
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Es una prueba de acuerdo cliente-aplicador
bull Se recomienda entre el 10 y el 15 del
espesor del sistema que se va a aplicar
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3241
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3341
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3441
Distributed by
PERFIL DE ANCLAJE
bull Se mide copiando el perfil mediante plaacutesticosespeciales y llevaacutendolo a un microacutemetro
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3541
Distributed by
CONDICIONES AMBIENTALES
bull Norma astm e337
bull Temperatura de chapabull Debe ser superior minimo en 3degc a la temperatura decrocio
bull Tem eratura ambiental
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
La reaccion de una pintura epoxica se detiene a menos de4degc
bull Humedad relativa
bull Se mide mediante higrometros ninguna pintura epoxica o
base solvente debe ser aplicada si la humedad relativa essuperior al 85
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3641
Distributed by
DETECCION DE DISCONTINUIDADES
bull Norma astm d 5162-91
bull Detectores bajo voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la pelicula mediantela circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se usa generalmente un detector entre 6 y 50 voltiosde corriente directa
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3741
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3841
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm d 5162-91
bull Detectores de alto voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se utilizan entre 1500 vol y 25000 vol
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3941
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm g 62-87
bull Detectores de alto voltaje para tuberias
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull
Se utilizan entre 1500 vol y 25000 volbull Los valores de prueba dependen de los
espesores del recubrimiento
Di t ib t d b
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4041
Distributed by
CONCLUSION
Para lograr un perfecto desempentildeo de unrecubrimiento debemos cubrir todas las fases delproceso de aplicacioacuten y seleccioacuten de forma integralEsto solo se lo ra con el total conocimiento or arte
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
de los involucrados de las teacutecnicas y caracteriacutesticasde los productos que usamos
Distributed by
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4141
Distributed by
Pinturas para mantenimiento
GRACIAS
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2741
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull Procedimiento seguacuten norma astm d4541
bull Criterios(Seguacuten norma ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull a preparac on e super c e es a gra o comerc a yla pintura es base amida la tension minima es 710 psi
bull Si la preparacion de superficie es a grado comercial yla pintura es base amina la tension minima es 400 psi
bull
Si es poliuretano sobre pinturas aminas o amidas latension minima es 280 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2841
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios(Seguacuten norma icontec ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Si la preparacion es manual-mecanica la medicioncalificara indirectamente la calidad de la preparacion desuperficie
bull Si la pintura es un esmalte alquidico se debe esperar 15dias y la presion minima debe ser 250 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2941
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3041
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3141
Distributed by
PERFIL DE ANCLAJE
bull
Es la distancia promedio entre los picos y losvalles generados por la preparacion desuperficie
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Es una prueba de acuerdo cliente-aplicador
bull Se recomienda entre el 10 y el 15 del
espesor del sistema que se va a aplicar
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3241
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3341
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3441
Distributed by
PERFIL DE ANCLAJE
bull Se mide copiando el perfil mediante plaacutesticosespeciales y llevaacutendolo a un microacutemetro
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3541
Distributed by
CONDICIONES AMBIENTALES
bull Norma astm e337
bull Temperatura de chapabull Debe ser superior minimo en 3degc a la temperatura decrocio
bull Tem eratura ambiental
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
La reaccion de una pintura epoxica se detiene a menos de4degc
bull Humedad relativa
bull Se mide mediante higrometros ninguna pintura epoxica o
base solvente debe ser aplicada si la humedad relativa essuperior al 85
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3641
Distributed by
DETECCION DE DISCONTINUIDADES
bull Norma astm d 5162-91
bull Detectores bajo voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la pelicula mediantela circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se usa generalmente un detector entre 6 y 50 voltiosde corriente directa
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3741
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3841
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm d 5162-91
bull Detectores de alto voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se utilizan entre 1500 vol y 25000 vol
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3941
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm g 62-87
bull Detectores de alto voltaje para tuberias
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull
Se utilizan entre 1500 vol y 25000 volbull Los valores de prueba dependen de los
espesores del recubrimiento
Di t ib t d b
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4041
Distributed by
CONCLUSION
Para lograr un perfecto desempentildeo de unrecubrimiento debemos cubrir todas las fases delproceso de aplicacioacuten y seleccioacuten de forma integralEsto solo se lo ra con el total conocimiento or arte
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
de los involucrados de las teacutecnicas y caracteriacutesticasde los productos que usamos
Distributed by
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4141
Distributed by
Pinturas para mantenimiento
GRACIAS
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2841
Distributed by
PRUEBA DE ADHERENCIA POR TENSION
bull
Norma astm d4541
bull Criterios(Seguacuten norma icontec ntc 3951)
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Si la preparacion es manual-mecanica la medicioncalificara indirectamente la calidad de la preparacion desuperficie
bull Si la pintura es un esmalte alquidico se debe esperar 15dias y la presion minima debe ser 250 psi
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2941
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3041
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3141
Distributed by
PERFIL DE ANCLAJE
bull
Es la distancia promedio entre los picos y losvalles generados por la preparacion desuperficie
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Es una prueba de acuerdo cliente-aplicador
bull Se recomienda entre el 10 y el 15 del
espesor del sistema que se va a aplicar
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3241
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3341
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3441
Distributed by
PERFIL DE ANCLAJE
bull Se mide copiando el perfil mediante plaacutesticosespeciales y llevaacutendolo a un microacutemetro
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3541
Distributed by
CONDICIONES AMBIENTALES
bull Norma astm e337
bull Temperatura de chapabull Debe ser superior minimo en 3degc a la temperatura decrocio
bull Tem eratura ambiental
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
La reaccion de una pintura epoxica se detiene a menos de4degc
bull Humedad relativa
bull Se mide mediante higrometros ninguna pintura epoxica o
base solvente debe ser aplicada si la humedad relativa essuperior al 85
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3641
Distributed by
DETECCION DE DISCONTINUIDADES
bull Norma astm d 5162-91
bull Detectores bajo voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la pelicula mediantela circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se usa generalmente un detector entre 6 y 50 voltiosde corriente directa
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3741
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3841
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm d 5162-91
bull Detectores de alto voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se utilizan entre 1500 vol y 25000 vol
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3941
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm g 62-87
bull Detectores de alto voltaje para tuberias
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull
Se utilizan entre 1500 vol y 25000 volbull Los valores de prueba dependen de los
espesores del recubrimiento
Di t ib t d b
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4041
Distributed by
CONCLUSION
Para lograr un perfecto desempentildeo de unrecubrimiento debemos cubrir todas las fases delproceso de aplicacioacuten y seleccioacuten de forma integralEsto solo se lo ra con el total conocimiento or arte
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
de los involucrados de las teacutecnicas y caracteriacutesticasde los productos que usamos
Distributed by
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4141
Distributed by
Pinturas para mantenimiento
GRACIAS
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 2941
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3041
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3141
Distributed by
PERFIL DE ANCLAJE
bull
Es la distancia promedio entre los picos y losvalles generados por la preparacion desuperficie
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Es una prueba de acuerdo cliente-aplicador
bull Se recomienda entre el 10 y el 15 del
espesor del sistema que se va a aplicar
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3241
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3341
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3441
Distributed by
PERFIL DE ANCLAJE
bull Se mide copiando el perfil mediante plaacutesticosespeciales y llevaacutendolo a un microacutemetro
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3541
Distributed by
CONDICIONES AMBIENTALES
bull Norma astm e337
bull Temperatura de chapabull Debe ser superior minimo en 3degc a la temperatura decrocio
bull Tem eratura ambiental
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
La reaccion de una pintura epoxica se detiene a menos de4degc
bull Humedad relativa
bull Se mide mediante higrometros ninguna pintura epoxica o
base solvente debe ser aplicada si la humedad relativa essuperior al 85
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3641
Distributed by
DETECCION DE DISCONTINUIDADES
bull Norma astm d 5162-91
bull Detectores bajo voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la pelicula mediantela circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se usa generalmente un detector entre 6 y 50 voltiosde corriente directa
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3741
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3841
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm d 5162-91
bull Detectores de alto voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se utilizan entre 1500 vol y 25000 vol
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3941
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm g 62-87
bull Detectores de alto voltaje para tuberias
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull
Se utilizan entre 1500 vol y 25000 volbull Los valores de prueba dependen de los
espesores del recubrimiento
Di t ib t d b
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4041
Distributed by
CONCLUSION
Para lograr un perfecto desempentildeo de unrecubrimiento debemos cubrir todas las fases delproceso de aplicacioacuten y seleccioacuten de forma integralEsto solo se lo ra con el total conocimiento or arte
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
de los involucrados de las teacutecnicas y caracteriacutesticasde los productos que usamos
Distributed by
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4141
Distributed by
Pinturas para mantenimiento
GRACIAS
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3041
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3141
Distributed by
PERFIL DE ANCLAJE
bull
Es la distancia promedio entre los picos y losvalles generados por la preparacion desuperficie
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Es una prueba de acuerdo cliente-aplicador
bull Se recomienda entre el 10 y el 15 del
espesor del sistema que se va a aplicar
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3241
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3341
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3441
Distributed by
PERFIL DE ANCLAJE
bull Se mide copiando el perfil mediante plaacutesticosespeciales y llevaacutendolo a un microacutemetro
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3541
Distributed by
CONDICIONES AMBIENTALES
bull Norma astm e337
bull Temperatura de chapabull Debe ser superior minimo en 3degc a la temperatura decrocio
bull Tem eratura ambiental
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
La reaccion de una pintura epoxica se detiene a menos de4degc
bull Humedad relativa
bull Se mide mediante higrometros ninguna pintura epoxica o
base solvente debe ser aplicada si la humedad relativa essuperior al 85
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3641
Distributed by
DETECCION DE DISCONTINUIDADES
bull Norma astm d 5162-91
bull Detectores bajo voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la pelicula mediantela circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se usa generalmente un detector entre 6 y 50 voltiosde corriente directa
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3741
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3841
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm d 5162-91
bull Detectores de alto voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se utilizan entre 1500 vol y 25000 vol
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3941
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm g 62-87
bull Detectores de alto voltaje para tuberias
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull
Se utilizan entre 1500 vol y 25000 volbull Los valores de prueba dependen de los
espesores del recubrimiento
Di t ib t d b
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4041
Distributed by
CONCLUSION
Para lograr un perfecto desempentildeo de unrecubrimiento debemos cubrir todas las fases delproceso de aplicacioacuten y seleccioacuten de forma integralEsto solo se lo ra con el total conocimiento or arte
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
de los involucrados de las teacutecnicas y caracteriacutesticasde los productos que usamos
Distributed by
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4141
Distributed by
Pinturas para mantenimiento
GRACIAS
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3141
Distributed by
PERFIL DE ANCLAJE
bull
Es la distancia promedio entre los picos y losvalles generados por la preparacion desuperficie
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Es una prueba de acuerdo cliente-aplicador
bull Se recomienda entre el 10 y el 15 del
espesor del sistema que se va a aplicar
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3241
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3341
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3441
Distributed by
PERFIL DE ANCLAJE
bull Se mide copiando el perfil mediante plaacutesticosespeciales y llevaacutendolo a un microacutemetro
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3541
Distributed by
CONDICIONES AMBIENTALES
bull Norma astm e337
bull Temperatura de chapabull Debe ser superior minimo en 3degc a la temperatura decrocio
bull Tem eratura ambiental
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
La reaccion de una pintura epoxica se detiene a menos de4degc
bull Humedad relativa
bull Se mide mediante higrometros ninguna pintura epoxica o
base solvente debe ser aplicada si la humedad relativa essuperior al 85
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3641
Distributed by
DETECCION DE DISCONTINUIDADES
bull Norma astm d 5162-91
bull Detectores bajo voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la pelicula mediantela circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se usa generalmente un detector entre 6 y 50 voltiosde corriente directa
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3741
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3841
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm d 5162-91
bull Detectores de alto voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se utilizan entre 1500 vol y 25000 vol
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3941
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm g 62-87
bull Detectores de alto voltaje para tuberias
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull
Se utilizan entre 1500 vol y 25000 volbull Los valores de prueba dependen de los
espesores del recubrimiento
Di t ib t d b
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4041
Distributed by
CONCLUSION
Para lograr un perfecto desempentildeo de unrecubrimiento debemos cubrir todas las fases delproceso de aplicacioacuten y seleccioacuten de forma integralEsto solo se lo ra con el total conocimiento or arte
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
de los involucrados de las teacutecnicas y caracteriacutesticasde los productos que usamos
Distributed by
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4141
Distributed by
Pinturas para mantenimiento
GRACIAS
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3241
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3341
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3441
Distributed by
PERFIL DE ANCLAJE
bull Se mide copiando el perfil mediante plaacutesticosespeciales y llevaacutendolo a un microacutemetro
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3541
Distributed by
CONDICIONES AMBIENTALES
bull Norma astm e337
bull Temperatura de chapabull Debe ser superior minimo en 3degc a la temperatura decrocio
bull Tem eratura ambiental
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
La reaccion de una pintura epoxica se detiene a menos de4degc
bull Humedad relativa
bull Se mide mediante higrometros ninguna pintura epoxica o
base solvente debe ser aplicada si la humedad relativa essuperior al 85
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3641
Distributed by
DETECCION DE DISCONTINUIDADES
bull Norma astm d 5162-91
bull Detectores bajo voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la pelicula mediantela circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se usa generalmente un detector entre 6 y 50 voltiosde corriente directa
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3741
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3841
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm d 5162-91
bull Detectores de alto voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se utilizan entre 1500 vol y 25000 vol
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3941
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm g 62-87
bull Detectores de alto voltaje para tuberias
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull
Se utilizan entre 1500 vol y 25000 volbull Los valores de prueba dependen de los
espesores del recubrimiento
Di t ib t d b
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4041
Distributed by
CONCLUSION
Para lograr un perfecto desempentildeo de unrecubrimiento debemos cubrir todas las fases delproceso de aplicacioacuten y seleccioacuten de forma integralEsto solo se lo ra con el total conocimiento or arte
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
de los involucrados de las teacutecnicas y caracteriacutesticasde los productos que usamos
Distributed by
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4141
Distributed by
Pinturas para mantenimiento
GRACIAS
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3341
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3441
Distributed by
PERFIL DE ANCLAJE
bull Se mide copiando el perfil mediante plaacutesticosespeciales y llevaacutendolo a un microacutemetro
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3541
Distributed by
CONDICIONES AMBIENTALES
bull Norma astm e337
bull Temperatura de chapabull Debe ser superior minimo en 3degc a la temperatura decrocio
bull Tem eratura ambiental
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
La reaccion de una pintura epoxica se detiene a menos de4degc
bull Humedad relativa
bull Se mide mediante higrometros ninguna pintura epoxica o
base solvente debe ser aplicada si la humedad relativa essuperior al 85
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3641
Distributed by
DETECCION DE DISCONTINUIDADES
bull Norma astm d 5162-91
bull Detectores bajo voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la pelicula mediantela circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se usa generalmente un detector entre 6 y 50 voltiosde corriente directa
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3741
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3841
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm d 5162-91
bull Detectores de alto voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se utilizan entre 1500 vol y 25000 vol
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3941
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm g 62-87
bull Detectores de alto voltaje para tuberias
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull
Se utilizan entre 1500 vol y 25000 volbull Los valores de prueba dependen de los
espesores del recubrimiento
Di t ib t d b
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4041
Distributed by
CONCLUSION
Para lograr un perfecto desempentildeo de unrecubrimiento debemos cubrir todas las fases delproceso de aplicacioacuten y seleccioacuten de forma integralEsto solo se lo ra con el total conocimiento or arte
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
de los involucrados de las teacutecnicas y caracteriacutesticasde los productos que usamos
Distributed by
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4141
Distributed by
Pinturas para mantenimiento
GRACIAS
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3441
Distributed by
PERFIL DE ANCLAJE
bull Se mide copiando el perfil mediante plaacutesticosespeciales y llevaacutendolo a un microacutemetro
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3541
Distributed by
CONDICIONES AMBIENTALES
bull Norma astm e337
bull Temperatura de chapabull Debe ser superior minimo en 3degc a la temperatura decrocio
bull Tem eratura ambiental
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
La reaccion de una pintura epoxica se detiene a menos de4degc
bull Humedad relativa
bull Se mide mediante higrometros ninguna pintura epoxica o
base solvente debe ser aplicada si la humedad relativa essuperior al 85
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3641
Distributed by
DETECCION DE DISCONTINUIDADES
bull Norma astm d 5162-91
bull Detectores bajo voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la pelicula mediantela circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se usa generalmente un detector entre 6 y 50 voltiosde corriente directa
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3741
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3841
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm d 5162-91
bull Detectores de alto voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se utilizan entre 1500 vol y 25000 vol
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3941
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm g 62-87
bull Detectores de alto voltaje para tuberias
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull
Se utilizan entre 1500 vol y 25000 volbull Los valores de prueba dependen de los
espesores del recubrimiento
Di t ib t d b
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4041
Distributed by
CONCLUSION
Para lograr un perfecto desempentildeo de unrecubrimiento debemos cubrir todas las fases delproceso de aplicacioacuten y seleccioacuten de forma integralEsto solo se lo ra con el total conocimiento or arte
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
de los involucrados de las teacutecnicas y caracteriacutesticasde los productos que usamos
Distributed by
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4141
Distributed by
Pinturas para mantenimiento
GRACIAS
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3541
Distributed by
CONDICIONES AMBIENTALES
bull Norma astm e337
bull Temperatura de chapabull Debe ser superior minimo en 3degc a la temperatura decrocio
bull Tem eratura ambiental
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull
La reaccion de una pintura epoxica se detiene a menos de4degc
bull Humedad relativa
bull Se mide mediante higrometros ninguna pintura epoxica o
base solvente debe ser aplicada si la humedad relativa essuperior al 85
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3641
Distributed by
DETECCION DE DISCONTINUIDADES
bull Norma astm d 5162-91
bull Detectores bajo voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la pelicula mediantela circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se usa generalmente un detector entre 6 y 50 voltiosde corriente directa
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3741
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3841
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm d 5162-91
bull Detectores de alto voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se utilizan entre 1500 vol y 25000 vol
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3941
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm g 62-87
bull Detectores de alto voltaje para tuberias
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull
Se utilizan entre 1500 vol y 25000 volbull Los valores de prueba dependen de los
espesores del recubrimiento
Di t ib t d b
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4041
Distributed by
CONCLUSION
Para lograr un perfecto desempentildeo de unrecubrimiento debemos cubrir todas las fases delproceso de aplicacioacuten y seleccioacuten de forma integralEsto solo se lo ra con el total conocimiento or arte
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
de los involucrados de las teacutecnicas y caracteriacutesticasde los productos que usamos
Distributed by
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4141
Distributed by
Pinturas para mantenimiento
GRACIAS
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3641
Distributed by
DETECCION DE DISCONTINUIDADES
bull Norma astm d 5162-91
bull Detectores bajo voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la pelicula mediantela circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se usa generalmente un detector entre 6 y 50 voltiosde corriente directa
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3741
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3841
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm d 5162-91
bull Detectores de alto voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se utilizan entre 1500 vol y 25000 vol
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3941
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm g 62-87
bull Detectores de alto voltaje para tuberias
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull
Se utilizan entre 1500 vol y 25000 volbull Los valores de prueba dependen de los
espesores del recubrimiento
Di t ib t d b
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4041
Distributed by
CONCLUSION
Para lograr un perfecto desempentildeo de unrecubrimiento debemos cubrir todas las fases delproceso de aplicacioacuten y seleccioacuten de forma integralEsto solo se lo ra con el total conocimiento or arte
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
de los involucrados de las teacutecnicas y caracteriacutesticasde los productos que usamos
Distributed by
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4141
Distributed by
Pinturas para mantenimiento
GRACIAS
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3741
Distributed by
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3841
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm d 5162-91
bull Detectores de alto voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se utilizan entre 1500 vol y 25000 vol
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3941
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm g 62-87
bull Detectores de alto voltaje para tuberias
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull
Se utilizan entre 1500 vol y 25000 volbull Los valores de prueba dependen de los
espesores del recubrimiento
Di t ib t d b
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4041
Distributed by
CONCLUSION
Para lograr un perfecto desempentildeo de unrecubrimiento debemos cubrir todas las fases delproceso de aplicacioacuten y seleccioacuten de forma integralEsto solo se lo ra con el total conocimiento or arte
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
de los involucrados de las teacutecnicas y caracteriacutesticasde los productos que usamos
Distributed by
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4141
Distributed by
Pinturas para mantenimiento
GRACIAS
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3841
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm d 5162-91
bull Detectores de alto voltaje
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull Se utilizan entre 1500 vol y 25000 vol
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3941
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm g 62-87
bull Detectores de alto voltaje para tuberias
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull
Se utilizan entre 1500 vol y 25000 volbull Los valores de prueba dependen de los
espesores del recubrimiento
Di t ib t d b
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4041
Distributed by
CONCLUSION
Para lograr un perfecto desempentildeo de unrecubrimiento debemos cubrir todas las fases delproceso de aplicacioacuten y seleccioacuten de forma integralEsto solo se lo ra con el total conocimiento or arte
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
de los involucrados de las teacutecnicas y caracteriacutesticasde los productos que usamos
Distributed by
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4141
Distributed by
Pinturas para mantenimiento
GRACIAS
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 3941
Distributed by
DETECCION DE DISCONTINUIDADES
bull
Norma astm g 62-87
bull Detectores de alto voltaje para tuberias
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
bull Detecta cualquier discontinuidad en la peliculamediante la circulacion de corriente electrica
bull Se debe correr a 03 ms
bull
Se utilizan entre 1500 vol y 25000 volbull Los valores de prueba dependen de los
espesores del recubrimiento
Di t ib t d b
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4041
Distributed by
CONCLUSION
Para lograr un perfecto desempentildeo de unrecubrimiento debemos cubrir todas las fases delproceso de aplicacioacuten y seleccioacuten de forma integralEsto solo se lo ra con el total conocimiento or arte
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
de los involucrados de las teacutecnicas y caracteriacutesticasde los productos que usamos
Distributed by
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4141
Distributed by
Pinturas para mantenimiento
GRACIAS
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4041
Distributed by
CONCLUSION
Para lograr un perfecto desempentildeo de unrecubrimiento debemos cubrir todas las fases delproceso de aplicacioacuten y seleccioacuten de forma integralEsto solo se lo ra con el total conocimiento or arte
Criterios Generales
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
de los involucrados de las teacutecnicas y caracteriacutesticasde los productos que usamos
Distributed by
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4141
Distributed by
Pinturas para mantenimiento
GRACIAS
Protective CoatingsAll products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale
7252019 Inspeccioacuten de Pintura en Campo
httpslidepdfcomreaderfullinspeccion-de-pintura-en-campo 4141
Distributed by
Pinturas para mantenimiento
GRACIAS