The perfect match for: Pumps Fans Compressors Mixers Conveyors and many more Power range: 7.5–110 kW VL T® Compact Start er MCD 200 from Danfoss includes two families of soft starters in t he power range from 7.5–110 kW.  The series offer easy DIN rail mount- ing for sizes up to 30 kW, 2-wire or 3-wire start/stop control and excellent starting duty (4 x I e for 6 seconds). Heavy starting ratings at 4x I e for 20 seconds. Compatible with grounded delta power systems. Features Benets • S mall footprint and compact size Saves panel space Built-in bypass Minimises installation cost and eliminates power loss Advanced accessories • Allows enhanced function ality • I nternal delta wiring kit • The soft starter carries only phase current, and can therefore control a motor with greater full load current Reliable Maximum up-time • Essential motor pr ot ec ti on s ( MC D 20 2) • Redu ce s over al l pr oj ec t i nv es tm en t Pass word protection of parameters Prevents unauthoriz ed changes • Max. ambient temperature 50 ˚C without derating No external cooling or ov ersizing necessary User-friendly  Save commissioning and operating cost Easy to install and use • Eas y D IN rail moun ting f or siz es up to 30 kW • Saves time and spa ce  MCD 201 MCD 202 MCD 202 provides enhanced soft start functionality and various motor protection features Ramp up Initial torque Ramp down U M 3~ M 3~ Ramp up Initial current Current limit Ramp down U I VLT® Compact Starter MCD 200

Transcript of ARRANCADORES SUAVES MCD200

Page 1: ARRANCADORES SUAVES MCD200

7/29/2019 ARRANCADORES SUAVES MCD200

http://slidepdf.com/reader/full/arrancadores-suaves-mcd200 1/2

The perfect match for:

• Pumps

• Fans

• Compressors

• Mixers

• Conveyors• and many more

Power range:

7.5–110 kW

VLT® Compact Starter MCD 200 from Danfoss includes twofamilies of soft starters in the power range from 7.5–110 kW.

 The series offer easy DIN rail mount-

ing for sizes up to 30 kW, 2-wire or

3-wire start/stop control and excellent

starting duty (4 x Ie

for 6 seconds).

Heavy starting ratings at 4x Ie

for 20

seconds.

Compatible with grounded delta

power systems.

Features Benefits

• Small footprint and compact size • Saves panel space

• Built-in bypass • Minimises installation cost and eliminatespower loss

• Advanced accessories • Allows enhanced functionality

• Internal delta wiring kit • The soft starter carries only phase current,and can therefore control a motor withgreater full load current

Reliable – Maximum up-time

• Essential motor protections (MCD 202) • Reduces overall project investment

• Pass word protection of parameters • Prevents unauthorized changes

• Max. ambient temperature 50̊ Cwithout derating

• No external cooling or oversizing necessary

User-friendly – Save commissioning

and operating cost

• Easy to install and use •

• Easy DIN rail mounting for sizes up to 30 kW • Saves time and space

 MCD 201 MCD 202

MCD 202 providesenhanced soft startfunctionality and variousmotor protection features

Ramp up

Initial torque

RampdownU M

3~M3~

Ramp up

Initial current

Currentlimit

Rampdown

UI

VLT® Compact Starter MCD 200

Page 2: ARRANCADORES SUAVES MCD200

7/29/2019 ARRANCADORES SUAVES MCD200

http://slidepdf.com/reader/full/arrancadores-suaves-mcd200 2/2

Specifications

Danfoss Drives, Ulsnaes 1, DK-6300 Graasten, Denmark, Tel. +45 74 88 22 22, Fax +45 74 65 25 80, www.danfoss.com/drives • E-mail: [email protected]

 

MP011A02 VLT® is a trademark of Danfoss A/S Produced by KKM 2007.05

Mains supply (l1, L2, L3)

Supply voltage3 x 200 VAC – 440 VAC or3 x 200 – 575 VAC

Supply frequency 45 – 66 Hz

Control voltage

100 – 240 VAC380 – 440 VAC24 VDC/24 VAC

Control inputs

Control inputsStart, StopReset upsh button on the unit

Relay outputs

Relay outputs1 x main contactor1 x programmable* (Trip or Run)

Protections, MCD 201Phase sequenceSupply faultShorted SCR

Protections, MCD 202

Motor thermistor inputMotor temperature – thermal modelPhase imbalancePhase sequenceExcess start timeSupply faultShorted SCR

LED indications

Indications

Ready/Fault

Run

Ambient operating temperature

Ambient temperature -5 to 60˚C (above 40˚C without derating)

Standards approvals

Approvals CE, UL, C-UL, CCC, C-tick  

Soft Starter for motorsup to 110 kW• Total motor starting solution• Start, stop and protection features• Local programming keypad and

display

Optional:• Modules for serial communication• Remote operator kit• PC software• Pump application module

Remote operator kitRemote Operator and display with

4–20 mA analogue output propor-

tional to motor current (MCD 202)

Serial communication: Modbus RTU,

AS-i, Profibus and DeviceNet.

PC-based MCD set-up software.

Power range(400V)

7–30 kW 37–55 kW 75–110 kW

Height [mm] 190 200 232

Width [mm] 96 140 280

Depth [mm] 152 176 TBA

Cabinet sizes