BALANCEO DE EQUIPOS1. Primero realizaremos las curvas del compresor,2. Realizar las líneas de la curva del evaporador.3. Realizar un diagrama COMPRESOR vs EVAPORADOR, para intersectar los puntos y poder contar
con una UC
-11 -10 -9 -8 -7 -6 -5 -4 -3 -2 -1 0 1 2 3 4 5 6 7 8 90
20000
40000
60000
80000
100000
120000
140000
160000
30°C
50°C
40°C
50°C
40°C
30°Ccondensador
evaporador
![Page 2: Balance](https://reader036.fdocuments.es/reader036/viewer/2022081816/55cf9153550346f57b8c99ad/html5/thumbnails/2.jpg)
PARA EL COMPRESOR:
30°Cx y
-20 47190
-15 61144
-10 77584
-5 96864
0 119384
5 145605
10 176070
50°C
x y-20 32372
-15 43742
-10 57016
-5 72465
0 90391
5 111135
10 135089
PARA EL CONDENSADOR EVAPORATIVO:
Para 30°C
x y -10 594472.2 4.13
-8 409509.3 2.845-7 374244 2.6-6 313069.5 2.175-5 267728.4 1.86-4 243978.3 1.695-3 217349.4 1.51-2 200796.3 1.395-1 187122 1.30 177765.9 1.2351 165890.85 1.15252 154015.8 1.073 146458.95 1.01754 138902.1 0.9655 133144.5 0.9256 127386.9 0.8857 122349 0.858 117311.1 0.815
Para 40°C Para 50°C
40°Cx y
-20 39785
-15 52458
-10 67329
-5 84710
0 104953
5 128460
10 155696
![Page 3: Balance](https://reader036.fdocuments.es/reader036/viewer/2022081816/55cf9153550346f57b8c99ad/html5/thumbnails/3.jpg)
BALANCEO PARA EL TUNEL DE ENFRIAMIENTO
Unidad Condensadora Evaporador
x y3.9 140000
-2.4 95000-5.9 70000
-7 50000-8 15000
-22 -20 -18 -16 -14 -12 -10 -8 -6 -4 -2 0 2 4 60
20000
40000
60000
80000
100000
120000
140000
160000
Capacidad balanceada del túnel de enfriamiento: 17 kW
X Y factor-10 143940 1
-8 124508.1 0.865-7 117311.1 0.815-6 111553.5 0.775-5 105795.9 0.735-4 101477.7 0.705-3 97159.5 0.675-2 94280.7 0.655-1 91401.9 0.6350 87803.4 0.611 85644.3 0.5952 83485.2 0.583 81685.95 0.56754 77007.9 0.5355 76648.05 0.53256 76288.2 0.537 75208.65 0.52258 74129.1 0.515
X Y Factor-10 81086.2 0.435
-8 81086.2 0.435-7 75293.2 0.38-6 70613.9 0.4-5 60576 0.385-4 54697.2 0.38-3 56856.3 0.395-2 53977.5 0.375-1 52538.1 0.3650 54697.2 0.38
X Y-5 15027
-20 30054
![Page 4: Balance](https://reader036.fdocuments.es/reader036/viewer/2022081816/55cf9153550346f57b8c99ad/html5/thumbnails/4.jpg)
BALANCEO DE LA CAMARA SOLAR
Unidad Condensadora Evaporador
x y3.9 140000
-2.4 95000-5.9 70000
-7 50000-8 15000
-22 -20 -18 -16 -14 -12 -10 -8 -6 -4 -2 0 2 4 60
20000
40000
60000
80000
100000
120000
140000
160000
Capacidad balanceada de la cámara solar: 19 kw
BALANCEO DE LAS CAMARAS DE ENFRIAMIENTO
Unidad Condensadora Evaporador
x y3.9 140000
-2.4 95000-5.9 70000
-7 50000-8 15000
X Y-5 17090
-20 34180
X Y-5 15035
-20 30070
![Page 5: Balance](https://reader036.fdocuments.es/reader036/viewer/2022081816/55cf9153550346f57b8c99ad/html5/thumbnails/5.jpg)
-22 -20 -18 -16 -14 -12 -10 -8 -6 -4 -2 0 2 4 60
20000
40000
60000
80000
100000
120000
140000
160000
Capacidad balanceada de la cámara de enfriamiento: 17 kw