    Produced by SAGEM Dfense Scurit

    Copyright 2007 SAGEM Dfense Scurit

    www.sagem.com

    MA500 Series Enrolment Application User Guide

    SK-0000062337-00-02

    April 2007

    MorphoAccess TM 500 Series

  • 8/12/2019 biometrico configuracion 5002

    2/22

    2 SAGEM Dfense Scurit document. Reproduction and disclosure forbidden.

  • 8/12/2019 biometrico configuracion 5002

    3/22

    SAGEM Dfense Scurit document. Reproduction and disclosure forbidden 3

    APPLICATION SELECTION 6 ADMINISTRATOR LOGIN 6

    BASE STATUS 9 CREATE DATABASE 9 DATABASE EXPORTATION 10 BASE IMPORTATION 12

    USER ENROLMENT 15 USER DELETION 18

    CHANGE P ASSWORD 19 INFORMATION 20

  • 8/12/2019 biometrico configuracion 5002

    4/22

    4 SAGEM Dfense Scurit document. Reproduction and disclosure forbidden.

  • 8/12/2019 biometrico configuracion 5002

    5/22

    SAGEM Dfense Scurit document. Reproduction and disclosure forbidden 5

    In stand-alone mode, the MorphoAccess TM manages its own localdatabase with the Using this application a new user can be directly enroled with the terminalsensor.

    The local database can be exported, encrypted by specific keys, on astandard USB key and imported on another MorphoAccess TM.

  • 8/12/2019 biometrico configuracion 5002

    6/22

    6 SAGEM Dfense Scurit document. Reproduction and disclosure forbidden.

    AApppp lliiccaa ttiioonn ss ee llee cc ttiioonn

    The is launched from the menu.

    A possible running application must be exited to display the menu.

    Keys and allow to select an application in the list.

    Key launches the selected application.

    Select to start the application.

    AAddmm iinn iiss ttrraa ttoorr lloogg iinn

    The application is protected by the .

    By default is 12345.

    If a user in the biometric database has administration rights it is possibleto start the application with a biometric control.

    Please refer to section Administration rights for more information aboutadministration rights.

    If the password is invalid, another attempt is possible.

  • 8/12/2019 biometrico configuracion 5002

    7/22

    SAGEM Dfense Scurit document. Reproduction and disclosure forbidden 7

    If the Administrator uses the default password it is possible to change itimmediately.

    Please refer to the Password Modification chapter to change the

    Note: For security reasons, it is strongly advised to change this passwordas soon as you receive the terminal.

  • 8/12/2019 biometrico configuracion 5002

    8/22

    8 SAGEM Dfense Scurit document. Reproduction and disclosure forbidden.

    The Main Menu is divided in 4 items:

    1. Base Management is dedicated to database management (creation,status).

    2. User Management permits to enroll users into the terminal database.

    3. Configuration allows to change the password.

    4. Quit leaves the application.

  • 8/12/2019 biometrico configuracion 5002

    9/22

    SAGEM Dfense Scurit document. Reproduction and disclosure forbidden 9

    This menu allow s the database 0 managing .

    Keys and allow to browse the list.

    Key selects an item.

    BBaa ss ee ss ttaa ttuuss The menu returns the local database capacity and the number of thecurrently enrolled users.

    A user has two fingerprints template.

    CCrree aa ttee ddaa ttaa bbaa ss ee

    This operation creates a database with ID 0. This database can contain3000 records with two biometric data fields, an ID field and, if theBiometric login is enabled, an Administrator field.

    If a database already exists, all previous records are erased.

  • 8/12/2019 biometrico configuracion 5002

    10/22

    10 SAGEM Dfense Scurit document. Reproduction and disclosure forbidden.

    DDaa ttaa bbaa ss ee EE xxppoorrttaa ttiioonn

    This operation allows to export the local database on a (UMS).

    The database is ciphered on the media.

    The database can be exported later on another MorphoAccess TM.

    The database must have been created with the function.

    Key capacity must not exceed 1GB.

    Key must be FAT16 (FAT) formatted.

    The terminal waits for a Mass Storage key insertion.

  • 8/12/2019 biometrico configuracion 5002

    11/22

    SAGEM Dfense Scurit document. Reproduction and disclosure forbidden 11

    Base name must be entered.

    By default base name is baseYYMMDD.

    A password will ensure database ciphering on the media.

    This password will be required during database importation on anotherMorphoAccess TM.

    Base exportation and ciphering can last 2 minutes.

    At the end of the exportation a message gives the exportation status.

  • 8/12/2019 biometrico configuracion 5002

    12/22

    12 SAGEM Dfense Scurit document. Reproduction and disclosure forbidden.

    BBaa ss ee IImm ppoorrttaa ttiioonn

    This function imports a database previously exported from anotherMorphoAccess.

    Key capacity must not exceed 1GB.

    Key must be FAT16 (FAT) formatted and must contain a database atthe root.

    The terminal waits for a Mass Storage key insertion.

    The terminal browses the list of databases stored on the key.

  • 8/12/2019 biometrico configuracion 5002

    13/22

    SAGEM Dfense Scurit document. Reproduction and disclosure forbidden 13

    In order to import the base the terminal requires the security codepreviously entered during database exportation phase.

    Base importation will delete the current database: all records can be lost.

    Base importation and deciphering can last 2 minutes.

    At the end of the importation a message gives the importation status.

  • 8/12/2019 biometrico configuracion 5002

    14/22

    14 SAGEM Dfense Scurit document. Reproduction and disclosure forbidden.

    This menu is dedicated to enroll or un-enroll a user.

    Keys and allow to browse the list.

    Key selects an item.

  • 8/12/2019 biometrico configuracion 5002

    15/22

    SAGEM Dfense Scurit document. Reproduction and disclosure forbidden 15

    UUss ee rr EEnnrroollmm ee nn tt

    Enrolment consists in adding user fingerprints (templates) in the localdatabase.

    User fingerprints are captured by the sensor, coded and stored in the localdatabase.

    User identifier is the main key of the fingerprints database.

    It can be numerical (for Wiegand system) or alphanumeric.

    It is limited to 24 characters.

    To display a letter press repeatedly the corresponding key to cycle thecharacters.

    For example, to enter press three times the key. requires

    cycling six times key and ).

    The enro lled person may be either a simple user or an administrator.

    An administrator can access to the application with a biometric

    authentication.

  • 8/12/2019 biometrico configuracion 5002

    16/22

    16 SAGEM Dfense Scurit document. Reproduction and disclosure forbidden.

    The user name and first name can be stored.

    Enrolment consists in capturing two different fingerprints (typically rightand left thumbs). Each fingerprint needs three acquisitions..

    Between each fingers capture , the finger must be removed from thesensor.

    The second finger must be different from the first one.

  • 8/12/2019 biometrico configuracion 5002

    17/22

    SAGEM Dfense Scurit document. Reproduction and disclosure forbidden 17

    A final screen displays the enrolment result.

    If templates already exist in the database, user is not enrolled.

    If both fingers are identical an error is reported.

  • 8/12/2019 biometrico configuracion 5002

    18/22

    18 SAGEM Dfense Scurit document. Reproduction and disclosure forbidden.

    UUss ee rr DDee llee ttiioonn

    To remove a user from the local database, the administrator must enterhis identifier.

    If the user does not exist, a message informs the administrator that thereis no corresponding user.

    If the identifier matches, the corresponding user, his templates and hisdata (administrator parameter)) are removed from the database.

  • 8/12/2019 biometrico configuracion 5002

    19/22

    SAGEM Dfense Scurit document. Reproduction and disclosure forbidden 19

    This menu allows to change the password and returns information about

    the sensor and the application.

    CChhaa nnggee PP aa ss ss wwoorrdd

    To change the the old password must be

    previously entered.

    The new password must be entered and confirmed.

  • 8/12/2019 biometrico configuracion 5002

    20/22

    20 SAGEM Dfense Scurit document. Reproduction and disclosure forbidden.

    If password confirmation matches the password is changed.

    If confirmation fails, the new password must be entered and confirmedagain.

    There is no way to reinitialize the password.

    IInn ffoorrmm aa ttiioonn

    This menu returns the software revisions of the and

    of the sensor firmware.