    Shrouded single or multi-channel impeller pumps with large throughletsand single volute pump c asing for liquids containing solids and f ibres.Cast iron design with double sealing technology . Some modelsav ailable as stainless steel versions.

    Head

    646 345mm646 345mm

    68.3%

    0.0

    1.0

    2.0

    3.0

    4.0

    5.0

    6.0

    7.0

    8.0

    9.0

    10.0

    11.0

    12.0

    13.0

    14.0

    15.0

    16.0

    17.0

    18.0

    19.0

    20.0

    21.0

    22.0

    23.024.0

    25.0

    [m]

    0 40 80 120 160 200 240 280 [l/s]

    Impeller

    Frequency

    Motor

    Rated v oltage

    -

    Rated power

    Rated speed

    Number of poles

    Rated current

    200 V60 Hz

    55.9 kW

    6

    1160 1/min

    213 A

    CP 3300 MT 3~ 646

    Motor #

    3~

    Inlet diameter

    Dimensional drwg

    Weight

    DIMENSION TOENDS OFGUIDE BARS*

    Z - ZVIEWCLOFDISCH

    BOLT 20(4x)REF.LINE

    (TOFURTHESTPOINT)

    MIN LEVEL

    REF.LINE

    REF.LINE

    440

    500

    380

    1290

    1830

    194

    500

    500

    250

    75

    1655

    235

    630

    35816

    434 116

    135 716

    DN 300

    50

    *640

    800

    Z Z

    3"Guidebars

    CP 3300MT

    209

    277

    58

    Impeller diameter 345 mmNumber of blades 2Throughlet diameter 100 mm

    C3300.280 35-28-6AA-W 75hpStator v ariant 28

    Phases

    Starting current 984 A

    Technical specification

    Note: Picture might not correspond to the current c onfiguration.

    Power fact or

    Eff iciency

    1/1 Load3/4 Load1/2 Load

    1/1 Load3/4 Load1/2 Load

    0.890.900.88

    85.0 %86.5 %86.5 %

    250 mmCurve according to: ISO 9906

    P - Semi permanent, WetInstallation:

    Configuration

    Impeller material Stainless steel

    General

    Outlet width 250 mm

    Last updateCreated on

    2013-01-23

    Created byProject IDProject

  • 7/29/2019 Bomba 1

    2/6

    Head

    Efficiency

    Total efficiency

    Shaft power P2

    Power input P1

    NPSH-values

    646 345mm646 345mm

    68.3%

    646 345mm646 345mm646 345mm646 345mm

    646 345mm (P2)646 345mm (P2)646 345mm (P1)646 345mm (P1)

    646 345mm646 345mm

    01

    23456789

    101112131415161718

    19202122232425

    [m]

    0

    10

    20

    30

    40

    50

    60

    [%]

    0

    10

    20

    30

    [kW]

    6

    8

    10

    [m]

    0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 [l/s]

    Motor #

    60 Hz

    Phases 3~

    200 VNumber of poles 6

    Rated power 55.9 kW

    Starting currentRated current 213 A

    Rated speed 1160 1/min

    C3300.280 35-28-6AA-W 75hpStator variant

    Number of blades 2

    Power factor

    CP 3300 MT 3~ 646

    Inlet diameter

    Performance curve

    Pump

    Impeller diameter345 mm

    Throughlet diameter 100 mm

    Motor

    Rated voltage

    984 A

    Efficiency

    1/1 Load

    3/4 Load1/2 Load

    1/1 Load

    3/4 Load

    1/2 Load

    Frequency

    28 0.89

    85.0 %

    0.900.88

    86.5 %

    86.5 %

    250 mm

    Curve according to: ISO 9906

    Outlet width 250 mm

    Last updateCreated on

    2013-01-23

    Created byProject IDProject

  • 7/29/2019 Bomba 1

    3/6

    Head

    646 345mm

    68.3%

    10.2 m

    220.6 l/s0.0

    0.5

    1.0

    1.5

    2.0

    2.5

    3.0

    3.54.0

    4.5

    5.0

    5.5

    6.0

    6.5

    7.0

    7.5

    8.0

    8.5

    9.0

    9.5

    10.0

    10.511.0

    11.5

    12.0

    12.5

    13.0

    13.5

    14.0

    14.5

    15.0

    15.5

    16.0

    16.5

    17.0

    17.518.0

    18.5

    19.0

    19.5

    20.0

    20.5

    21.0

    21.5

    22.0

    22.5

    23.0

    23.5

    24.0

    24.5

    25.0

    25.5

    26.0

    [m]

    0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 [l/s]

    1

    CP 3300 MT 3~ 646Duty Analysis

    Curve according to: ISO 9906

    Indiv idual pump Total

    1 221 l/s 10.2 m 32.5 kW 221 l/s 10.2 m 32.5 kW 67.6 % 0.0469 kWh/m 8.06 m

    Pumpsrunning Specific/System Flow Head Shaft power Flow Head Shaft power Hyd eff. ener gy NPSHre

    Last updateCreated on

    2013-01-23

    Created byProject IDProject

  • 7/29/2019 Bomba 1

    4/6

    Head

    EfficiencyTotal efficiency

    Shaft power P2

    Power input P1

    NPSH-values

    646 345mm646 345mm

    68.3%

    55 Hz55 Hz50 Hz50 Hz

    45 Hz45 Hz40 Hz40 Hz

    646 345mm646 345mm55 Hz55 Hz50 Hz50 Hz45 Hz45 Hz40 Hz40 Hz646 345mm646 345mm55 Hz55 Hz50 Hz50 Hz45 Hz45 Hz40 Hz40 Hz

    646 345mm (P2)646 345mm (P2)

    55 Hz55 Hz50 Hz50 Hz

    45 Hz45 Hz40 Hz40 Hz

    646 345mm (P1)646 345mm (P1)55 Hz55 Hz50 Hz50 Hz45 Hz45 Hz40 Hz40 Hz

    646 345mm646 345mm

    55 Hz55 Hz

    50 Hz50 Hz

    45 Hz45 Hz

    40 Hz40 Hz

    0

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    1112

    13

    14

    15

    16

    17

    18

    19

    20

    21

    22

    23

    24

    25

    [m]

    0

    10

    20

    30

    40

    50

    60

    [%]

    0

    5

    10

    15

    20

    25

    30

    35

    [kW]

    2

    4

    6

    8

    10

    [m]

    0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 [l/s]

    CP 3300 MT 3~ 646VFD Curve

    Curve according to: ISO 9906

    Last updateCreated on

    2013-01-23

    Created byProject IDProject

  • 7/29/2019 Bomba 1

    5/6

    Head

    646 345mm

    68.3%

    10.2 m

    220.6 l/s

    55 Hz50 Hz

    45 Hz40 Hz

    0.0

    0.5

    1.0

    1.5

    2.0

    2.5

    3.0

    3.5

    4.0

    4.5

    5.0

    5.5

    6.0

    6.5

    7.0

    7.5

    8.0

    8.5

    9.0

    9.5

    10.0

    10.5

    11.0

    11.5

    12.0

    12.5

    13.0

    13.5

    14.0

    14.5

    15.0

    15.5

    16.0

    16.5

    17.0

    17.5

    18.0

    18.5

    19.0

    19.5

    20.0

    20.5

    21.0

    21.5

    22.0

    22.5

    23.0

    23.5

    24.0

    24.525.0

    25.5

    26.0

    [m]

    0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 [l/s]

    1

    CP 3300 MT 3~ 646VFD Analysis

    Curve according to: ISO 9906

    Indiv idual pump Total

    1 60 Hz 221 l/s 10.2 m 32.5 kW 221 l/s 10.2 m 32.5 kW 67.6 % 0.0469 kWh/m 8.06 m1 55 Hz 179 l/s 9.38 m 24.4 kW 179 l/s 9.38 m 24.4 kW 68.2 % 0.0438 kWh/m 6.07 m1 50 Hz 142 l/s 8.78 m 18.5 kW 142 l/s 8.78 m 18.5 kW 66.9 % 0.0427 kWh/m 4.64 m1 45 Hz 103 l/s 8.32 m 13.1 kW 103 l/s 8.32 m 13.1 kW 63.5 % 0.0434 kWh/m 3.58 m1 40 Hz 56.1 l/s 7.95 m 8.37 kW 56.1 l/s 7.95 m 8.37 kW 52.5 % 0.055 kWh/m 2.88 m

    Pumpsrunning Specific/System Frequency Flow Head Shaft power Flow Head Shaft power Hyd eff. ener gy NPSHre

    Last updateCreated on

    2013-01-23

    Created byProject IDProject

  • 7/29/2019 Bomba 1

    6/6

    CP 3300 MT 3~ 646Dimensional drawing

    Dimensional drwg

    Weight

    DIMENSION TOENDSOF GUIDEBARS*

    Z - ZVIEWCLOFDISCH

    BOLT 20(4x)REF.LINE

    (TOFURTHEST POINT)

    MIN LEVEL

    REF.LINE

    REF.LINE

    440

    500

    380

    1290

    1830

    194

    500

    500

    250

    75

    1655

    235

    630

    35816

    434 116

    135 716

    DN 300

    50

    *640

    800

    Z Z

    3" Guidebars

    CP 3300 MT

    2

    09

    277

    58

    Last updateCreated on

    2013-01-23

    Created byProject IDProject