DISEÑO ESTRUCTURAL DEL MEDIDOR DE CAUDAL PLANTA N° 3

t2 t1A' B'

HL

Sr S1H H1 Eq

H/2 EhWr W1 V1 = Vr

A B

H2H/3 S2

C D V2

W2 h2h1

hrT

DATOS DE DISEÑO

H = 0.80 m. t1 = 0.15 m. P.e. Co. ### kg/m3H1 = 0.65 m. t2 = 0.00 m. P.e. Rel ### kg/m3H2 = 0.15 m. T = 1.00 m. f'c = 210.00 kg/cm2HL = 0.15 m.

Ø = 25.00 grados σ suelo 0.93 kg/cm2Cohes 0.00 kg/cm2Ka = 0.41

Coeficiente Sísmico0.12 CZONA 1 0.15 TIPO III Suelo con gravas, arenas limosas, arenas 0.39ZONA 2 0.30 limosas y limos inorganicosZONA 3 0.40

Sr = 0.00 kg W1 = ### kgS/car 0.00 kg/m2 S1 = 28.08 kgC = 0.39 W2 = ### kg

S2 = 43.20 kgWr = 0.00 kg

Cargas Actuantes:Eh = Coef. Sísmico x Empuje Acti E activ Ka x P.e. x H^2/2Eq = Coef. Sísmico x Efecto Sobr Efecto C x S/C x H

Eh = ### kgEq = 0.00 kg

PROYECTO :“AMPLIACIÓN Y MEJORAMIENTO DE LOS SISTEMAS DE AGUA POTABLE Y

ALCANTARILLADO DEL DISTRITO DE PAUCARA, PROVINCIA DE ACOBAMBA, DEPARTAMENTO DE HUANCAVELICA”

Page 2: CALCULO MEDIDOR CAUDAL PLANTA N° 3

VERIFICACION DE LA SEGURIDAD AL VOLTEO EN TORNO AL PUNTO "C":

Mo de Volteo = Eh x H/3 + Eq x H/2 + Sr x Vr + S1 x V1 + S2 x V2

Mo de Volteo = 55.07 kg-m

Mo estabilizador Wr x hr + W1 x h1 + W2 x h2

Mo estabilizador ### kg-m

Coeficiente de Seguridad:

Mo estabilizador/Mo de volteo = 7.20 BIEN

VERIFICACION DE LA RESISTENCIA A COMPRESION DEL SUELO EN LA BASE "CD":

Sum Fv Sum Fv

Sum FhSum Fh M

C CG D C CG P DT e

T

Sumatoria Fh = Eh + Eq + Sr + S1 + S2

Sumatoria Fh = 248.93 kg

Sumatoria Fv = Wr + W1 + W2

Sumatoria Fv = 594.00 kg

Momento M = Eh x H/3 + Eq x H/2 + Sr x Vr + S1 x V1 + S2 x V2 - Wr x h'r - W1 x h'1

Momento M = 11.30 kg-m

Se cumple que: Suponiendo que los esfuerzos en la base son de compresión:

Sumat. Fv x e = M σ = Sumat. Fv/A +- M x T/2/I

e = 0.02 m σ = 0.06 + - 0.01

σ1 = 0.07 kg/cm2σ2 = 0.05 kg/cm2"

Todo el sistema de fuerzas sobre el muro puede reducirse al sistema de la figura (a), equivalente al sistema de la figura (b).

Page 3: CALCULO MEDIDOR CAUDAL PLANTA N° 3

Sum. Fv

CGe

R σ máx.

X/3X

T

X/3 = T/2 - e Sumatoria Fv = 1/2σ máx. x X x 100σ máx. = 2 x Sumat. Fv / (X x 100)

X = 144.29 cm

σ máx. 0.08 kg/cm2

σ suel 0.93 kg/cm2

DIMENSIONAMIENTO CORRECTO DE LA ESTRUCTURA

VERIFICACION DEL ESFUERZO CORTANTE EN LA SECCION "AB":

V = Eh1 + Eq1 + Sr + S1

Eh1 = 1.12 x (1/2 x Kh x H1^2)Eh1 = 177.65 kg

Eq1 = 1.12 x (C x q x H1)Eq1 = 0.00 kg

V = 205.73 kg

v = V/A = V / (d x b)

v = 0.21 kg/cm2

v < Vc CORRECTOVc = 0.29 x (f'c)^0.5

Vc = 4.20 kg/cm2

CALCULO DE LA ARMADURA EN LA CARA "A' - A":

M = Eh1 x H1/3 + Eq1 x H1/2 + Sr x V'r + S1 x V'1

M = 47.62 kg-m

k = n x fc / (fs + (n x fc)) As = M / (fs x j x d)

Page 4: CALCULO MEDIDOR CAUDAL PLANTA N° 3

n = Es / Ec 10fs = 0.50xfy 2100 kg/cm2 As = 0.23 cm2fc <=0.45xf'c 94.50 kg/cm2j = 1 - (k/3) 0.90 CuantíaAs/(t1 x b) Cuant.Mín.Flex 0.00120r = 3.00 cmd = t1- r-Ø/ 11.00 cm Cuantía0.00015 Cuant.Mín.Tem 0.00180

El Refuerzo requerido en A - A' e 1.80 cm2 (Refuerzo Principal)

Diám. Fierro Corr.Area cm2Ø 5/8" 1 2.00 Tipo de Acero a Utiliz 3Ø 1/2" 2 1.29Ø 3/8" 3 0.71 Distribución del Acer Ø 3/8" @ 0.39

SE COLOCARA Ø = 3/8" cada 0.20

El Refuerzo por Temper. B - B' es 2.70 cm2 (Refuerzo por Temperatura)

Diám. Fierro Corr.Area cm2Ø 5/8" 1 2.00 Tipo de Acero a Utiliz 3Ø 1/2" 2 1.29Ø 3/8" 3 0.71 Distribución del Acer Ø 3/8" @ 0.26

SE COLOCARA Ø = 3/8" cada 0.20

El Refuerzo Horizontal A - A' es : 3.00 cm2 (Refuerzo Horizontal)

Ø 5/8" 1 2.00 Tipo de Acero a Utiliz 3Ø 1/2" 2 1.29Ø 3/8" 3 0.71 Distribución del Acer Ø 3/8" @ 0.24

SE COLOCARA Ø = 3/8" cada 0.20

CALCULO DE LA ARMADURA DE LA ZAPATA:

Esquema de Fuerzas para el Diseño por Flexión:

C CG DR

σ máx. 0.08kg/cm2

X = 1.44

Esquema de Fuerzas para laVerificación por Corte: 0.18 0.67

0.00 0.15 0.85

1.00

Page 5: CALCULO MEDIDOR CAUDAL PLANTA N° 3
Page 6: CALCULO MEDIDOR CAUDAL PLANTA N° 3

0.04kg/cm2 σ máx. 0.08

kg/cm2V

M = R x 2/3 x X As = M / (fs x j x d)

M = ### kg-m As = 2.76 cm2

CuantíaAs/(H2 x b) Cuant.Mín.Flex 0.00120

Cuantía0.00184 Cuant.Mín.Tem 0.00180

El Refuerzo requerido en Zapata 2.76 cm2 (Refuerzo Principal)

Diám. Fierro Corr.Area cm2Ø 5/8" 1 2.00 Tipo de Acero a Utiliz 3Ø 1/2" 2 1.29Ø 3/8" 3 0.71 Distribución del Acer Ø 3/8" @ 0.26

SE COLOCARA Ø = 3/8" cada 0.20m.

El Refuerzo por Temper. Zapata 2.70 cm2 (Refuerzo por Temperatura)

Diám. Fierro Corr.Area cm2Ø 5/8" 1 2.00 Tipo de Acero a Utiliz 3Ø 1/2" 2 1.29Ø 3/8" 3 0.71 Distribución del Acer Ø 3/8" @ 0.26

SE COLOCARA Ø = 3/8" cada 0.20 m. Esfuerzo Cortante:

V = 422.42 kg

v = V / (d x b)

v = 0.38 kg

Vc = 0.29 x f'c^0.50 v < Vc CORRECTO

Vc = 4.20 kg/cm2