CALCULO DE SECCION DE ALCANTARILLADO PLUVIAL proyecto: MEJORAMIENTO DE LA PLAZA DE ARMAS DE LA LOCALIAD DE VISTOSO, DISTRITO DE SAN PEDRO DE CHANA, HUARI, ANCSH TRAMO QAUDAL COMPROB. Jr. Ramirez 0.957 0.017 0.04 0.51 0.60 0.0438 0.60 0.02628 0.6876 0.0382 1.4 0.142 2.12 Supercritico 0.60 X 0.60 3,402.35 3,399.62 62.83 0.036562332606 Jr. Cushin 1.276 0.017 0.041 0.57 0.60 0.0621 0.60 0.03726 0.7242 0.0514 1.7 0.202 2.12 Supercritico 0.60 X 0.60 3,399.51 3,395.50 96.70 0.061741299374 Jr. Toledo 0.832 0.017 0.063 0.45 0.60 0.0328 0.60 0.01968 0.6656 0.0296 1.4 0.134 2.49 Supercritico 0.60 X 0.60 3,402.05 3,399.00 48.54 0.027747086854 Jr. Obregon 0.456 0.017 0.130 0.31 0.60 0.0126 0.60 0.00756 0.6252 0.0121 1.1 0.076 3.18 Supercritico 0.60 X 0.60 3,404.00 3,402.50 11.50 0.008461320277 LA SECCION DE DISEÑO SE TOMARA DE: 0.60 x 0.60 M. COMO MINIMO, POR FACTORES TRABAJABILIDAD EN EL ALCANTARILLADO, ESPECIALMENTE EN EL ENCOFRADO Y DESENCOFRADO. COEFICIENTE DE RUGOSIDAD (n) PENDIENTE S(m/m) ANCHO CALCULADO b (m) ANCHO DISEÑO b (m) TIRANTE y (m) ALTURA DISEÑO h (m) AREA HIDRAULICA (m^2) PERIMETRO P (m) RADIO HIDRAULICO R (m) VELOCIDAD V (m/s) ENERGIA ESPECIFICA E (m) NUMERO DE FROUDE TIPO DE FLUJO SECCION DE DISEÑO COTA DE FONDO AGUAS ARRIBA COTA DE FONDO AGUA ABAJO LONGITUD L (m)

description

diseño de alcantarillado

Transcript of Diseño de Alcantarillado

Hoja1CALCULO DE SECCION DE ALCANTARILLADO PLUVIAL

proyecto:MEJORAMIENTO DE LA PLAZA DE ARMAS DE LA LOCALIAD DE VISTOSO, DISTRITO DE SAN PEDRO DE CHANA, HUARI, ANCSH

TRAMOQAUDALCOEFICIENTE DE RUGOSIDAD (n)PENDIENTE S(m/m)ANCHO CALCULADO b (m)ANCHO DISEO b (m)TIRANTE y (m)ALTURA DISEO h (m)AREA HIDRAULICA (m^2)PERIMETRO P (m)RADIO HIDRAULICO R (m)VELOCIDAD V (m/s)ENERGIA ESPECIFICA E (m)NUMERO DE FROUDETIPO DE FLUJOSECCION DE DISEOCOTA DE FONDO AGUAS ARRIBACOTA DE FONDO AGUA ABAJOLONGITUD L (m)COMPROB.

Jr. Ramirez0.9570.0170.040.510.600.04380.600.026280.68760.03821.40.1422.12Supercritico0.60 X 0.603,402.353,399.6262.830.0365623326Jr. Cushin1.2760.0170.0410.570.600.06210.600.037260.72420.05141.70.2022.12Supercritico0.60 X 0.603,399.513,395.5096.700.0617412994Jr. Toledo0.8320.0170.0630.450.600.03280.600.019680.66560.02961.40.1342.49Supercritico0.60 X 0.603,402.053,399.0048.540.0277470869Jr. Obregon0.4560.0170.1300.310.600.01260.600.007560.62520.01211.10.0763.18Supercritico0.60 X 0.603,404.003,402.5011.500.0084613203

LA SECCION DE DISEO SE TOMARA DE: 0.60 x 0.60 M. COMO MINIMO, POR FACTORES TRABAJABILIDAD EN EL ALCANTARILLADO, ESPECIALMENTE EN EL ENCOFRADO Y DESENCOFRADO.