heidenhain-355-v70
-
Upload
donald-santana-bautista -
Category
Documents
-
view
215 -
download
0
Transcript of heidenhain-355-v70
-
8/12/2019 heidenhain-355-v70
1/2
Page 1 of 2
Heidenhain TNC 355NCnet 7.0 settings
Set these parameters on the machine
MP232 = 0 (data transfer mode)
MP71 = 515 (character for program start and end)MP222 = 104 (data format)
To set the controller in the Drip-feed modeDrip feed is not available on this controller.
Set these parameters on the PC
Machine details
Machine name MCH-1Control system HeidenhainMachine ID 01Communication Channel Serial Port
Port Number Any free COM portFolder for PC to Machine transfer Transmit directory
Folder for Machine to PC transfer Receive directoryBaud rate 2400Data bits 7
Parity EvenStop bits 2Handshake Hardware
General settingsIgnore this. Leave all data as it is.
Transmit settings
Wait period at start of transmission 10.00Wait period after transmitting program 5.0Size of transmit packet 0
Delay period after each packet 0Wait for XON before transmitting program No
Transmit comments? YesComment start character (
Comment end character )
Translation mode for CR Transmit as CR
Translation mode for LF Transmit as LF
Acknowledgement and error (Mode of transmission) Transmit descriptive message
ACK/ERR Message start text %1234G71G50
ACK/ERR Message start text M30%1234G71G50
Filter Null Character Yes
-
8/12/2019 heidenhain-355-v70
2/2
Page 2 of 2
NC Program settings
Program start string
Program end string
Characters to transmit at start Number of Characters
Characters to transmit at start Number of Characters
Receive settings
Wait period before receiving program 45.0Wait period after receiving program 5.0Transmit XON before transmitting program No
Auto compare and save YesAcknowledgements and errors Transmit descriptive messagesTranslation mode for CR Ignore
Translation mode for LF Save as CRLF
Ignore control characters other than CR-LF Yes
Save Program between Start Characters and End Characters NoStart Program reception after these characters are received
End Program reception after these characters are received
To set the PC in the Drip-feed modeDrip feed is not available on this controller.
Cable connections
If the PC has 9 pin connector
Null modem Full Handshake
PC9 pin
1234567
8
82320764
5
CNC25 pin
PC9 pin
1234567
8
82367205
4
CNC25 pin
If the PC has 25 pin connector
Null modem Full Handshake
PC
25 pin
82
3207
64
5
83
2207
645
CNC
25 pin
PC
25 pin
82
3207
64
5
83
267
2054
CNC
25 pin