MANTTO ANUAL A TRANSFORMADOR 1500 KVAEFECTUAR LIBRANZA DE EQUIPOCORRECION DE PUNTOS DE OXIDO EN GABINETECORRECION DE PUNTOS DE OXIDO EN RADIADORESLIMPIEZA GENERAL A TRANSFORMADORAPLICAR PROTECCION PRIMARIOAPLICAR PINTURA ACABADOS TENIENDO CUIDADO DE PROTEGER INSTRUMENTACIONREALIZAR MEDICION DE AISLAMIENTO ANEXAR VALORES VOLT APLIC 5000 VOLT APLIC 500 VOLT APLIC 5000TIEMPO ALTA VS BAJA + T BAJA VS ALTA + T ALTA VS BAJA15'' ________MOHMS _______MOHMS ________MOHMS30'' ________MOHMS _______MOHMS ________MOHMS45'' ________MOHMS _______MOHMS ________MOHMS01' ________MOHMS _______MOHMS ________MOHMS02' ________MOHMS _______MOHMS ________MOHMS03' ________MOHMS _______MOHMS ________MOHMS04' ________MOHMS _______MOHMS ________MOHMS05' ________MOHMS _______MOHMS ________MOHMS06' ________MOHMS _______MOHMS ________MOHMS07' ________MOHMS _______MOHMS ________MOHMS08' ________MOHMS _______MOHMS ________MOHMS09' ________MOHMS _______MOHMS ________MOHMS10' ________MOHMS _______MOHMS ________MOHMSIP ____ IA_____REALIZAR MEDICION DE TTR ANEXAR VALORESPOSICION VOLTAJE DE RELACION RELACIONDERIVADOR CONEXION EXCITACION TEORICA MEDIDA % DIF 1 X0-X1 vs H1-H3 _____ _______ _______ ______ 1 X0-X2 vs H2-H1 _____ _______ _______ ______ 1 X0-X3 vs H3-H2 _____ _______ _______ ______ 2 X0-X1 vs H1-H3 _____ _______ _______ ______
2 X0-X2 vs H2-H1 _____ _______ _______ ______ 2 X0-X3 vs H3-H2 _____ _______ _______ ______ 3 X0-X1 vs H1-H3 _____ _______ _______ ______ 3 X0-X2 vs H2-H1 _____ _______ _______ ______ 3 X0-X3 vs H3-H2 _____ _______ _______ ______ 4 X0-X1 vs H1-H3 _____ _______ _______ ______ 4 X0-X2 vs H2-H1 _____ _______ _______ ______ 4 X0-X3 vs H3-H2 _____ _______ _______ ______ 5 X0-X1 vs H1-H3 _____ _______ _______ ______ 5 X0-X2 vs H2-H1 _____ _______ _______ ______ 5 X0-X3 vs H3-H2 _____ _______ _______ ______
REALIZAR MEDICION DE RIGIDEZ DIELECTRICA ANEXAR VALORES1ra MUESTRA 2da MUESTRA 3ra MUESTRAPRUEBA PUNTO DE FALLA PUNTO DE FALLA PUNTO DE FALLA 1.- ______ KV ______ KV ______ KV 2.- ______ KV ______ KV ______ KV 3.- ______ KV ______ KV ______ KVPROMEDIO ______ KV ______ KV ______ KV
MANTENIMIENTO A INTERRUPTOR PRIMARIO 4160 VCAMANTENIMIENTO A INTERRUPTOR SECUNDARIO 480 VCARELAIZAR MEDICION DE PUNTOS CALIENTES EN CAJAS DE CONEXIONCAJA DE 480 VOLTS Ø A ____ ºC Ø B ____ ºC Ø C ____ ºCCAJA DE 4160 VOLTS Ø A ____ ºC Ø B ____ ºC Ø C ____ ºCAPLICAR POTENCIAL Y REALIZAR PUESTA EN SERVICIOVERIFICAR OPERACION