  • CALCULO DE ARMADURA DE RESERVORIO

    DATOSPROYECTO :AGUA POTABLE PAGO CARABAYA ACERO MUROS EXPEDIENTE : ACERO VERTICAL = 1/2 Pulg.ZONAL : DIAMETRO = 1.270 Cms.EVALUADOR :CARLOS L AREA = 1.267 Cms2.FECHA : 3-Aug-15 PESO = 0.994 Kg/ml

    ACERO HORIZONTAL = 3/8 Pulg.DIAMETRO = 0.953 Cms.

    CARACTERISTICAS GEOMETRICAS AREA = 0.713 Cms2.VOLUMEN RESERVORIO = 10.00 m3 PESO = 0.560 Kg/ml

    ALTURA UTIL RESERVORI = 1.35 mts.LADO UTIL RESERVORIO = 2.75 mts. ACERO LOSA DE TECHO

    ESPECIFICACIONES ACERO HORIZONTAL = 3/8 Pulg.CONCRETO f'c = 210 Kg/cm2 DIAMETRO = 0.953 Cms.SOBRECARGA EN LOSA = 150 Kg/m2 AREA = 0.713 Cms2.ACERO fy = 4,200 Kg/cm2 PESO = 0.560 Kg/mlRESISTENCIA DEL SUELO = 1.50 Kg/cm2 ACERO LOSA DE FONDOCOEF. SISMICO = 0.12 ACERO HORIZONTAL = 3/8 Pulg.RECUBRIMIENTO r = = 4.00 Cm DIAMETRO = 0.953 Cms.fs = 2,100 Kg/cm2 AREA = 0.713 Cms2.fc = 94.5 Kg/cm2 PESO = 0.560 Kg/ml

    0.20 0.15 1.38

    1.73

    1.73

    Sc WcSL 0.10

    A' B'0.30

    WL NIVEL DE AGUA

    S1

    1.35Ea

    1.95 1.90 W1 0.45

    1.03 Wa

    A B

    S2 0.20

    0.10

    C D

    W2

    0.28

    0.87

    1.04

  • CALCULOS

    W1= Pc x V1 594.00 KgW2 = Pc x V2 830.40 KgWa = Pa x Va 1863.00 KgWL = Pc x VL 367.20 KgWs = Sc x A 229.50 KgS1 = 0,12 x W1 106.92 KgS2 = 0,12 x W2 149.47 KgSL = 0,12 x WL 66.10 KgSs = 0,12 x Ws 49.57 KgEa = 1,12 x 0,5 x Pa x H12 1530.90 Kg

    VERIFICACION DEL ESFUERZO CORTANTE EN LA BASE AB

    V = Fh / A 1.17 Kg/cm2

    Vc = 0,29 ( f'c )^1/2 4.20 Kg/cm2

    V= 1.17 Kg/cm2 < Vc = 4.20 Kg/cmBIEN !!

    CALCULO DE LA ARMADURA

    ACERO VERTICAL CARA B'-B

    MOMENTO MAXIMO EN LA BASE A-B

    Mu 976.23 Kg-mts.d = t1 - r - D/2 10.37 Cms.

    AREA DE ACEROAs1 = 85.54 Cms2As2 = 2.57 Cms2 SE ASUME : 2.57 Cms2

    CUANTIA = As / t1 x b 0.0017

    CUANTIA MINIMA POR FLEXION 0.0012 < 0.0017 BIEN!!

    USAR : 1 1/2 @ 0.30 mts.

    ACERO HORIZONTAL B'B

    ASUMIR CUANTIA MINIMA PARA EL ACERO HORIZONTAL, CONSIDERANDO P = 0,0018

    As = P x b x t1 2.70 Cms2

    USAR : 1 3/8 @ 0.26 mts.

    ACERO EN LA ZAPATA

    ASUMIR EL AREA DE ACERO HALLADA PARA LA BASE DE MURO

    USAR : 1 1/2 @ 0.30 mts.

    ACERO EN LA LOSA DE FONDO

    P1 3370.896P2 5452.92P3 4918.32P4 8619.55P5 15425.64

    LUEGO: 4035.56270.00

    4305.56

    WuD :WuL :

    Wu :

  • CALCULO DEL MOMENTO ULTIMO

    2068.19 Kg--mtsd = t1 - r - D/2 15.52 Cms.AREA DE ACEROAs1 = 128.33 Cms2As2 = 3.62 Cms2 SE ASUME : 3.62 Cms2

    CUANTIA = As / t1 x b 0.00181

    CUANTIA MINIMA POR FLEXION 0.0012 < 0.0018 BIEN!!

    USAR : 1 3/8 @ 0.20 mts.

    ACERO EN LA LOSA DE TECHO

    360WuL = SC * 1,8 270

    Wu = 630

    CALCULO DEL MOMENTO ULTIMO

    229.88 Kg--mtsd = t1 - r - D/2 5.72 Cms.AREA DE ACEROAs1 = 47.53 Cms2As2 = 1.09 Cms2 SE ASUME : 1.09 Cms2

    CUANTIA = As / t1 x b 0.00109

    CUANTIA MINIMA POR FLEXION 0.0012 > 0.0011 MAL!! SE ASUME CUANTIA MINIMA P= 0.0012

    As = P * t1 * b 1.20 Cms2

    USAR : 1 3/8 @ 0.25 mts

    Mu = 0,0513 * Wu * L2

    WuD = 2400 * t1 * 1,5

    Mu = 0,0479 * Wu * L2

  • 3.45

    0.15 0.30

    0.20 0.15 TUB. FG 3/4"@ 0,30 Mts.

    0.15

    1.6 UNIONESELECTROSOLDADAS

    0.10

    2.75

    ESCALINES FG

    VER DETALLE DETALLE DE ESCALINES

    BUZON 0,60 x 0,60 Mts.

    TAPA SANITARIA METALICA

    ESPECIFICACIONES TECNICAS

    0.15 RESISTENCIA DEL CONCRETO f'c = 175 Kg/cm2

    FLUENCIA DEL ACERO fy = 4200 Kg/cm2

    0.20 TRASLAPE MINIMO DE VARILLAS = 30 cm

    0.20 0.15 2.75 0.15 0.20

    FONCODESRESERVORIO APOYADO 10 M3

    PLANTAC. LOAYZA P. Aug-15

  • TAPA SANITARIA METALICA 3/8 @ 0.250,60 x 0,60 mts.

    0.10

    0.30

    NIVEL DE AGUA

    1/2 @ 0.30

    3/8 @ 0.26 TARRAJEO C / IMPERMEABILIZANTE 1.65

    1.35

    1/2 @ 0.30

    3/8 @ 0.20 PENDIENTE DE FONDO 1%

    3/8 @ 0.30

    0.20

    0.075

    0.92 SOLADO DE CONCRETO

    0.20 0.15 2.75 0.15 0.20

    FONCODESRESERVORIO APOYADO 10 M3

    CORTE A-AC. LOAYZA P. Aug-15

    TUBERIA DE VENTILACION FG 2"

  • 3/8 @ 0.25

    3.05

    2 3/8

    ESPECIFICACIONES TECNICAS

    RESISTENCIA DEL CONCRETO f'c = 175 Kg/cm2

    FLUENCIA DEL ACERO fy = 4200 Kg/cm2

    TRASLAPE MINIMO DE VARILLAS = 30 cm

    3.05 FONCODESRESERVORIO APOYADO 10 M3ARMADURA DE LOSA DE TECHO

    C. LOAYZA P. Aug-15

  • PLANILLA DE ARMADURA RESERVORIO 10 M3

    ARMADURA LOSA DE TECHO LONGITUD VECES PESO

    2.99

    0.07 3/8 3.13 26.4 46.27

    2.99

    3/8 2.99 4 6.70

    ARMADURA LOSA DE FONDO LONGITUD VECES PESO

    1.27

    0.17 1/2 1.44 50.00 40.23

    3.39

    3/8 3.39 16.22 30.80

    ARMADURA DE MURO LONGITUD VECES PESO

    0.11

    1.81 1/2 2.03 44.67 90.13

    0.15 2.90 3/8 6.25 14.69 51.42

    1.53

    PESO TOTAL EN Kg 265.55

  • HOJA DE METRADOS DE RESERVORIO

    CAPACIDAD : 10 M3

    PROYEC.: AGUA POTABLE PAGO CARABAYA EVALUADOR: CARLOS LEXPED.: 0 FECHA: 8/3/2015

    PARTIDA DESCRIPCION VECES LONG. ANCHO ALTURA SUB-TOTAL TOTAL UNID.

    6.00 RESERVORIO 10.00 M36.01 TRAZO Y REPLANTEO 1.00 3.45 3.45 11.90 11.90 m26.02 EXCAVACION MANUAL 1.00 3.45 3.45 0.80 9.52 9.52 m36.03 SOLADO DE CONCRETO E= 0.05 Mts. 1.00 3.45 3.45 11.90 11.90 m26.04 CONCRETO F'C= 175 KG/CM2 1.00 3.45 3.45 0.20 2.38 6.18 m3

    2.00 3.05 0.15 1.65 1.51 m32.00 2.75 0.15 1.65 1.36 m31.00 3.05 3.05 0.10 0.93 m3

    6.05 CONFOR. DE PENDIENTE DE FONDO C F'C= 175 K 1.00 2.75 2.75 7.56 7.56 m26.06 ENCOFRADO Y DESENCOFRADO 4.00 3.05 1.75 21.35 47.06 m2

    4.00 2.75 1.65 18.15 m21.00 2.75 2.75 7.56 m2

    6.07 ACERO FY= 4,200 KG/CM2 1.00 265.55 265.55 265.55 kg6.08 ESCALINES DE FIERRO GALVANIZADO 2.00 2.15 4.30 5.50 ml

    4.00 0.30 1.20

    6.09 TARRAJEO INTERIOR CON IMPERMEABILIZANTE 4.00 2.75 1.65 18.15 25.71 m21.00 2.75 2.75 7.56 m2

    6.10 TARRAJEO EXTERIOR MEZCLA 1:5 4.00 3.05 1.75 21.35 30.65 m21.00 3.05 3.05 9.30 m2

    6.11 TAPA SANITARIA METALICA 0,60 x 0,60 Mts. 1.00 1.00 1.00 unid6.12 TUBERIA DE VENTILACION FG D= 2" 1.00 1.00 1.00 unid6.13 PRUEBA HIDRAULICA Y DESINFEC. RESERVORIO 1.00 1.00 1.00 glb6.14 SUMINISTRO Y COLOCACION DE HIPOCLORADOR 1.00 1.00 1.00 unid6.15 PINTADO DE MUROS EXTERIORES 4.00 3.05 1.75 21.35 30.65 m2

    1.00 3.05 3.05 9.30

    TIEMPO DE EJECUCION DE OBRA

    PARTIDA DESCRIPCION UNID METRADO RENDI. PERSONAL PERSONAL BASE TIEMPO

    6.00 RESERVORIO 10.00 M36.01 TRAZO Y REPLANTEO m2 11.90 200.00 1.00 1.00 0.48 Hrs.6.02 EXCAVACION MANUAL m3 9.52 3.00 1.00 5.00 5.08 Hrs.6.03 SOLADO DE CONCRETO E= 0.05 Mts. m3 11.90 70.00 2.00 2.00 1.36 Hrs.6.04 CONCRETO F'C= 175 KG/CM2 m3 6.18 9.00 2.00 2.00 5.49 Hrs.6.05 CONFOR. DE PENDIENTE DE FONDO C F'C= 175 K m2 7.56 70.00 2.00 2.00 0.86 Hrs.6.06 ENCOFRADO Y DESENCOFRADO m2 47.06 10.00 1.00 5.00 7.53 Hrs.6.07 ACERO FY= 4,200 KG/CM2 kg 265.55 250.00 1.00 1.00 8.50 Hrs.6.08 ESCALINES DE FIERRO GALVANIZADO ml 5.50 15.00 1.00 1.00 2.93 Hrs.6.09 TARRAJEO INTERIOR CON IMPERMEABILIZANTE m2 25.71 6.00 1.00 2.00 17.14 Hrs.6.10 TARRAJEO EXTERIOR MEZCLA 1:5 m2 30.65 10.00 1.00 2.00 12.26 Hrs.6.11 TAPA SANITARIA METALICA 0,60 x 0,60 Mts. und 1.00 5.00 1.00 1.00 1.60 Hrs.6.12 TUBERIA DE VENTILACION FG D= 2" und 1.00 10.00 1.00 1.00 0.80 Hrs.6.13 PRUEBA HIDRAULICA Y DESINFEC. RESERVORIO glb 1.00 10.00 1.00 1.00 0.80 Hrs.6.14 SUMINISTRO Y COLOCACION DE HIPOCLORADOR und 1.00 10.00 1.00 1.00 0.80 Hrs.6.15 PINTADO DE MUROS EXTERIORES m2 30.65 25.00 1.00 1.00 9.81 Hrs.

    TIEMPO APROX. EJECUCION RESERVORIO. 9.43 Dias

  • VOLUMEN ALTURA LADO INTER VOLUMEN ASUMIDO3.00 1.25 1.55 10.00 M34.00 1.25 1.805.00 1.25 2.00 ALTURA LADO6.00 1.25 2.20 1.35 2.757.00 1.25 2.408.00 1.30 2.509.00 1.30 2.6510.00 1.35 2.7511.00 1.40 2.8512.00 1.45 2.9013.00 1.50 2.9514.00 1.55 3.0515.00 1.55 3.1516.00 1.60 3.2017.00 1.65 3.2518.00 1.65 3.3519.00 1.70 3.3520.00 1.70 3.4521.00 1.75 3.5022.00 1.75 3.5523.00 1.80 3.6024.00 1.85 3.6525.00 1.85 3.7026.00 1.85 3.7527.00 1.90 3.8028.00 1.90 3.8529.00 1.95 3.9030.00 1.95 3.9531.00 2.00 3.9532.00 2.00 4.0033.00 2.05 4.0534.00 2.05 4.1035.00 2.05 4.1536.00 2.10 4.1537.00 2.10 4.2038.00 2.15 4.2539.00 2.15 4.3040.00 2.15 4.3541.00 2.20 4.3542.00 2.20 4.4043.00 2.20 4.4544.00 2.25 4.4545.00 2.25 4.5046.00 2.25 4.5547.00 2.30 4.5548.00 2.30 4.6049.00 2.30 4.6550.00 2.35 4.6551.00 2.35 4.7052.00 2.45 4.6553.00 2.40 4.7054.00 2.40 4.7555.00 2.40 4.8056.00 2.40 4.8557.00 2.45 4.8558.00 2.45 4.9059.00 2.55 4.85

  • 60.00 2.45 4.95

    CALCULOSPLANTACORTE A-AARMADO LOSA TECHOPLANILLA ARMADURAMETRADOSCUADROS