UNIVERSIDAD CENTRAL DEL ECUADOR INGENIERÍA QUÍMICA ALUMNO: Margarita Vásquez Amaya SEMESTRE: Séptimo FECHA: 2012-12-06 MATERIA: Operaciones Unitarias 3 PROFESOR: ng! Mario "a##e TEMA: ENFRIAMIENTO DE AGUA POR EVAPORACIÓN PROBLEMA Se $ispone $e una torre $e en%riamiento $e &'m( $e a#tura y )'m 2 ( $e secci*n+ en #a que se quiere en%riar agua $es$e &0',"( en uito! .a torre tiene insta#a$o un /entero# $e capaci$a$ 20000 'm 3 ( para e# aire+ #a a#tura $e #a uni$a$ $e tras%erencia pue$e estimarse seg n H OH = 1,32 G v 0, LM !0," ! 4etermine #a canti$a$ $e agua que $e5e a#imentarse a #a torre para que #a temperatura $e sa#i$a sea $e 30 ',"(! '"on$iciones am5iente t 17',"( y t 8 1)',"(( FIGURA 1: D#$%&$'$ () F*+ -

description

diseño de torres

Transcript of Teresa Margarita Vásquez Amaya-tarea 3

UNIVERSIDAD CENTRAL DEL ECUADORINGENIERA QUMICA

ALUMNO: Margarita Vsquez Amaya SEMESTRE: Sptimo FECHA: 2012-12-06 MATERIA: Operaciones Unitarias 3 PROFESOR: Ing. Mario Calle TEMA: ENFRIAMIENTO DE AGUA POR EVAPORACINPROBLEMASe dispone de una torre de enfriamiento de 5(m) dealturay 4(m2)de seccin, en la que se quiere enfriar agua desde 50(C) en Quito. La torre tiene instalado un venterol de capacidad 20000 (m3/h) para el aire, la altura de la unidad de trasferencia puede estimarse segn: HOH= 1,32 Gv0,5LM-0,4. Determine la cantidad de agua que debe alimentarse a la torre para que la temperatura de salida sea de 30 (C). (Condiciones ambiente: t = 19(C) y tw = 14(C))FIGURA 1: Diagrama de Flujo

SOLUCINTABLA 1TENSIONES DE VAPOR DEL AGUATENSIONES DE VAPOR DE AGUA

t, (C)pw*, (mmHg)

1411.987

1512.788

1916.477

2017.535

2523.756

3031.824

3542.175

4055.324

4571.882

5092.511

FUENTE: http://www.vaxasoftware.com/doc_edu/qui/pvh2o.pdf

1. CONSTRUCCIN DEL DIAGRAMA ENTLPICO

1.1. CLCULO MODELO DE LA HUMEDAD ABSOLUTA DE SATURACIN DEL AIRE, PARA t=30C

1.2. CLCULO MODELO DE LA ENTALPA DEL AIRE, (H*) PARA t=30C

TABLA 1.2 1 DATOS PARA EL DIAGRAMA ENTLPICOt, (C)pw*, (mmHg)Ys, (kg vapor/kg aire seco)H*, (kcal/kg)

3031.8240.0386746530.8302133

3542.1750.0523153140.4849798

4055.3240.0704799152.9874317

4571.8820.0947992669.3764647

5092.5110.127604591.1403121

FIGURA 1.2 1: Diagrama Entlpico

2. CONDICIONES DE ENTRADA DEL AIRE A LA TORRE DE ENFRIAMIENTO2.1. HUMEDAD ABSOLUTATABLA 2.1 1 CONDICIONES AMBIENTALESP, (mmHg)542

t, (C)19

tw, (C)14

pw*, (mmHg)11.987

2.2. ENTALPA DE ENTRADA DEL AIRESE ASUME QUE LA TEMPERATURA DE SALIDA DEL AGUA ES APROXIMADAMENTE IGUAL A LA TEMPERATURA DEL AIRE A LA ENTRADA DE LA TORRE, POR EL NUEVO AMBIENTE GENERADO ALREDEDOR DE LA TORRE

2.3. DENSIDAD DEL AIRE

2.4. CLCULO DEL FLUJO MSICO DEL AIRE

3. CONSTRUCCIN DE LA RECTA DE OPERACINPara la recta de operacin y los dems clculos, se asume diferentes flujos msicos de agua, es decir que se debe iterar flujos diferentes de agua hasta lograr obtener la misma altura de la torre ya determina que es de 5(m).TABLA 3 1 FLUJOS MSICOS DE AGUA ASUMIDOS PARA LA ITERACINL, (kg/h)

25000

28000

29000

27500

28500

28981

3.1. Clculo modelo de la pendiente de operacin, para un flujo asumido de L=28981(kg/h)

3.2. Clculo modelo de la entalpa de salida del aire

3.3. RECTA DE OPERACIN

3.4. Clculo modelo de la entalpa para t=35C y 28981(kg/h)

TABLA 3.4 1DATOS PARA LA RECTA DE OPERACIN EN EL DIAGRAMA ENTLPICOt, (C)H, (Kcal/kg)

3013.9488781

3522.8187918

4031.6887055

4540.5586192

5049.4285329

FIGURA 4.4 1: Diagrama Entlpico modelo con Recta de Operacin

TABLA 3.4 2 RESULTADOS PARA DIFERENTES FLUJO MSICOS DE AGUA SUMIDOS EN LA ITERACINL, (kg/h)m,(kcal/kg*C)Hs, (kcal/kg)RECTA DE OPERACING/L

250001.5303044.5548396H=1.53030*tL-31.960064090.65346746

280001.7139348.227555H=1.71393*tL -37.469137150.58345309

290001.7751549.4517934H=1.77515*tL -39.305494840.56333402

275001.6833347.6154358H=1.68333*tL -36.550958310.59406133

285001.7445448.8396742H=1.74454*tL -38.3873160.57321707

289811.7739849.4285329H=1.77398*tL -39.270604050.56370334

TABLA 3.4 3DATOS PARA LA RECTA DE OPERACIN EN EL DIAGRAMA ENTLPICOt, (C)H, (Kcal/kg)

L=25000(kg/h)L=28000(kg/h)L=29000(kg/h)L=27500(kg/h)L=28500(kg/h)L=28981(kg/h)

3013.948878113.948878113.948878113.948878113.948878113.9488781

3521.600368522.518547322.82460722.365517522.671577222.8187918

4029.251858931.088216631.700335830.782156931.394276231.6887055

4536.903349239.657885840.576064639.198796440.116975240.5586192

5044.554839648.22755549.451793447.615435848.839674249.4285329

4. CLCULO DE NOH4.1. CLCULO MODELO DEL GRADIENTE FICTICIO DE ENTALPA, PARA t=30C Y 28981(kg/h)

TABLA 4.1 1RESULTADOS DEL GRADIENTE FICTICIO PARA DIFERENTES FLUJOS DE AGUA EN LA ITERACINt, (C)(H*-H), (Kcal/kg)

L=25000(kg/h)L=28000(kg/h)L=29000(kg/h)L=27500(kg/h)L=28500(kg/h)L=28981(kg/h)

3016.881335116.881335116.881335116.881335116.881335116.8813351

3518.884611317.966432517.660372918.119462317.813402717.666188

4023.735572921.899215221.287095922.205274821.593155621.2987262

4532.473115529.718578928.800400130.177668429.259489528.8178455

5046.585472542.912757241.688518743.524876442.300637941.7117792

4.2. CLCULO MODELO DE LA INVERSA DEL GRADIENTE FICTICIO DE ENTALPA, PARA t=30C

TABLA 4.2 2RESULTADOS DE LA INVERSA DEL GRADIENTE FICTICIO PARA DIFERENTES FLUJOS DE AGUAt, (C)[1/(H*-H)], (kg/kcal)

L=25000(kg/h)L=28000(kg/h)L=29000(kg/h)L=27500(kg/h)L=28500(kg/h)L=28981(kg/h)

300.059237020.059237020.059237020.059237020.059237020.05923702

350.052953170.055659350.056623950.055189280.056137510.05660531

400.042130860.045663740.046976820.045034340.046310970.04695116

450.03079470.033648980.034721740.033137090.034176950.03470072

500.021465920.023303090.023987420.022975370.023640310.02397404

TABLA 4.3 2DATOS PARA EL CLCULO DE NOHt, (C)L=25000(kg/h)L=28000(kg/h)L=29000(kg/h)L=27500(kg/h)L=28500(kg/h)L=28981(kg/h)

H, (Kcal/kg)H, (Kcal/kg)H, (Kcal/kg)H, (Kcal/kg)H,(Kcal/kg)H, (Kcal/kg)

300.06013.950.06013.950.06013.950.06016.880.06013.950.06013.95

350.05321.600.05622.520.05722.820.05518.120.05622.670.05722.82

400.04229.250.04631.090.04731.700.04522.210.04631.390.04731.69

450.03136.900.03439.660.03540.580.03330.180.03440.120.03540.56

500.02144.550.02348.230.02449.450.02343.520.02448.840.02449.43

FIGURA 4.1 1: Diagrama Modelo para [1/(H*-H)]=f(H)

TABLA 4.2 3RESULTADOS DE LAS ECUACIONES PARA EL CLCULO DEL NOHL, (kg/h)ECUACIN

25000[1/(H*-H)] = 1E-06H3 - 0.0001H2 + 0.0021H + 0.0493

28000[1/(H*-H)] = 1E-06H3 - 0.0001H2 + 0.0027H + 0.0413

29000[1/(H*-H)] = 1E-06H3 - 0.0001H2 + 0.0028H + 0.0390

27500[1/(H*-H)] = 1E-06H3 - 0.0001H2 + 0.0026H + 0.0425

28500[1/(H*-H)] = 1E-06H3 - 0.0001H2 + 0.0028H + 0.0401

28981[1/(H*-H)] = 1E-06H3 - 0.0001H2 + 0.0028H + 0.0390

4.3. Clculo modelo del NOH, para 28981(kg/h)

TABLA 4.3 1 RESULTADOS DE NOH PARA DIFERENTES FLUJOS DE AGUAL, (kg/h)NOH

250001.50691

280001.98737

290002.08087

275001.89287

285002.08633

289812.07962

5. CLCULO MODELO DEL HOH PARA 28981(kg/h)

TABLA 5 1 RESULTADOS DE HOH PARA DIFERENTES FLUJOS DE AGUAL, (kg/h)HOH, (m)

250002.5572543

280002.44391844

290002.40985394

275002.46159637

285002.42667701

289812.41048578

6. CLCULO MODELO DE LA ALTURA DE LA TORRE PARA 28981(kg/h)TABLA 6 1 RESULTADOS DE LA ALTURA DE LA TORRE PARA DIFERENTES FLUJOS DE AGUAL, (kg/h)HOH, (m)

250003.85355207

280004.85697019

290005.01459277

275004.65948192

285005.06284906

289815.01289444

CONCLUSIN:POR LO TANTO EL FLUJO MSICO DE AGUA QUE INGRESA A LA TORRE DE ENFRIAMIENTO PARA QUE EL AGUA QUE INGRESA A 50C SE ENFRE HASTA LOS 30C CON UNA CAPACIDAD DEL VENTEROL DE 20000(m3/h) EQUIVALENTES A 16336.89(kg/h) TIENE QUE SER DE:

7. RESULTADOS FINALES DESPUS DE LA ITERACIN DE LOS FLUJOS DE AGUATABLA 7 1 RESULTADOS FINALESpv,( mmHg)9.487G/L0.564

Ye, (kg vapor/kg aire seco)0.011045627m, (Kcal/kg*C)1.77398

Hentrada aire, (kcal/kg)13.94887813Hsalida aire, (Kcal/kg)49.4285329

aire,( kg/m3)0.816834329HOH, (m)2.41048578

G, (kg/h)16336.68657NOH2.07962

L,( kg/h)28981Z, m5.01289444

TORRE DE ENFRIAMIENTO

G=20000(m3/h)

te=tLs=30CYe=???He=???

Condiciones ambientales en QuitoPatm=542mmHgt=19Ctw=14C

ts=???

Ys=???Hs=???

AIRE CALIENTE Y HMEDO (SALIDA)

AGUA CALIENTE(ENTRADA)

L=???tLe=50C

Z=5m

A=4m2

AIRE FRO(ENTRADA)

AGUA FRA(SALIDA)

tLs=30C