Ver. 1.00

38
Ver. 1.00 2006 New Products SPLIT SPLIT Wall Mounted Type Wall Mounted Type FTXR-E series Heat Pump FTXR-E series Heat Pump DAIKIN Global Operations Division

description

2006 New Products SPLIT Wall Mounted Type FTXR-E series Heat Pump. Ver. 1.00. DAIKIN Global Operations Division. — Concept —. DAIKIN’s original NEW air conditioner with Humidity control. The first technology in the industry. Product Concept. Ururu ... Humidifying Operation - PowerPoint PPT Presentation

Transcript of Ver. 1.00

Page 1: Ver. 1.00

Ver. 1.00

2006 New ProductsSPLITSPLIT

Wall Mounted TypeWall Mounted TypeFTXR-E series Heat PumpFTXR-E series Heat Pump

2006 New ProductsSPLITSPLIT

Wall Mounted TypeWall Mounted TypeFTXR-E series Heat PumpFTXR-E series Heat Pump

DAIKIN Global Operations Division

Page 2: Ver. 1.00

2006 New Products2006 New Products 06RAG12-2

Product ConceptProduct Concept

—— Concept Concept ——

DAIKIN’s original NEW air conditioner with Humidity control.DAIKIN’s original NEW air conditioner with Humidity control.The first technology in the industry.The first technology in the industry.

UruruUruru ... ... Humidifying OperationHumidifying Operation creates humid aircreates humid air

SararaSarara ... ... Re-heater Dehumidifying OperationRe-heater Dehumidifying Operationcreates fresh aircreates fresh air

Page 3: Ver. 1.00

2006 New Products2006 New Products 06RAG12-3

FeaturesFeatures

< Indoor Unit >FTXR28/42/50EV1B

< Outdoor Unit >

RXR28/42/50EV1B

Humidity ControlNo Water Supply Humidifying OperationRe-heater Dehumidifying Operation

Ventilation & Air-purifyingAir Supply VentilationFlash Streamer Air-purifyingMold Shock Operation

Energy SavingAll "A" EER Label

Comfortable AirflowComfortable Airflow Mode

—— Features Features ——

Page 4: Ver. 1.00

2006 New Products2006 New Products 06RAG12-4

Product Line UpProduct Line Up

CapacityCapacityclassclass

Model nameModel name

Power supplyPower supplyIndoor unitIndoor unit Outdoor unitOutdoor unit

2.82.8kWkW FTXR28EV1BFTXR28EV1B RXR28EV1BRXR28EV1B

11220~230V220~230V

50Hz50Hz4.24.2kWkW FTXR42EV1BFTXR42EV1B RXR42EV1BRXR42EV1B

5.05.0kWkW FTXR50EV1BFTXR50EV1B RXR50EV1BRXR50EV1B

—— Heat Pump Heat Pump ——

Page 5: Ver. 1.00

2006 New Products2006 New Products 06RAG12-5

FunctionsFunctions

—— Function List Function List ——Function

Wide-angle louvers

Vertical auto-swing

Horizontal auto-swing

3-D airflow

Comfort airflow mode

Breeze cooling airflow

Auto fan speed

Indoor unit silent operation

Quick warming function

Hot-start function

Automatic defrosting

Automatic operation

Humidifying operation

Moisturizing operation

Dehumidifying operation

Dry cooling operation

Function

Wipe-clean flat panel

Washable upper grille

Filter cleaning indicator (Remote controller)

Mold proof operation

Mold shock operation

Mold proof stick

Comfort sleep operation

Supply ventilation

Home leave ventilation

24-Hr ON/OFF timer

Count up-down OFF timer

Night set mode

Auto-restart (after power failure)

Self-diagnosis (R/C, LED) display

Anticorrosion treatment of outdoor heat exchanger

Function

Streamer clean + fan

INV powerful operation

Indoor unit ON/OFF switch

Rainbow-colored multi monitor

Indoor unit indication ON/OFF setting

Signal reception indicator

I.D.&O.D. Temp. display (on R/C)

Humidity display (on R/C)

Child lock

Titanium apatite photocatalytic air purifying filter

Air intake filter

Streamer air-purifying

Mold proof air filter

(Function name is tentative.)(Function name is tentative.)

Page 6: Ver. 1.00

2006 New Products2006 New Products 06RAG12-6

Humidity ControlHumidity Control

—— Humidifying Operation Humidifying Operation ——Daikin’s original technology “No water supply humidifying”Daikin’s original technology “No water supply humidifying” Control not only temperature in a room but humidity.Control not only temperature in a room but humidity.

As moisture is absorbed from the outdoor air, humidification is possible even in the drier air of winter. It also means that you do not have to refill the water supply for the unit.

What’s good about humidifyingWhat’s good about humidifyingHumidified air creates a feeling of warmthand It prevents from getting too warm.Moderate humidification and a relatively low settemperature will leave you feeling warmer.Gentle to your skinThis function keep moderate humidification ina room, and treats your skin kindly. It effects well in a winter when your skin easily getsdry.

Outdoor unit

Moisture is extracted from the Outdoor air.

Page 7: Ver. 1.00

2006 New Products2006 New Products 06RAG12-7

Humidity ControlHumidity Control

—— Effect of Humidifying Effect of Humidifying ——

With a humidifier alone, humidified air stagnates in the upper part of the room.

With heating plus humidifyingYour room is filled with humidified air evenly throughout the room.

Humidification by air conditioner provides your room with moisture evenly as compared to a single humidifier.

Rather dry in lower space

Page 8: Ver. 1.00

2006 New Products2006 New Products 06RAG12-8

Humidity ControlHumidity Control

—— Effect of Humidifying Effect of Humidifying ——

Chilly

Room temp.: 28°C Humidity: 20%You feel cold in a dry air even at a higher temperature. Room temp.: 22°C Humidity: 50%

You feel comparatively warmer in humidified air.

warm

The thermograph shows the temperature distribution of the skin 30 min. after entry into the room.

30.0 35.0 40.0°C

You feel warmer in a humidified air even at a lower temperature.You feel warmer in a humidified air even at a lower temperature.

Page 9: Ver. 1.00

2006 New Products2006 New Products 06RAG12-9

Humidity ControlHumidity Control

—— Effect of Humidifying Effect of Humidifying ——

< Only heating > < Heating & humidifying >

- You feel free from dryness of skin- Skin is well conditioned.

Surface of dry skin exposed

to dry air

Adequately moisturized

skin

Heating plus humidifying operation keeps moderate humidity for your skin.Moreover “Moisturizing operation” gives you more moisture to protect your skin from dryness due to heating.

Page 10: Ver. 1.00

2006 New Products2006 New Products 06RAG12-10

Humidity ControlHumidity Control

——Humidifying mechanismHumidifying mechanism——

Humidifying hose

Humidifying rotor

Humidifying unit

The humidifying rotor absorb moisture from the outdoor air which has been sent to the humidifying unit. The moisture is supplied to the room through the humidifying hose.

Humidifying heater

To humidifying hose

Page 11: Ver. 1.00

2006 New Products2006 New Products 06RAG12-11

Humidity ControlHumidity Control

——Humidifying mechanismHumidifying mechanism——

1.1.Absorbs moistureAbsorbs moisture from the outdoor air from the outdoor airEven dry air in winter contains moisture. The humidifying rotor absorbs moisture from the outdoor air taken into the humidity absorption section by the humidifying fan.

Humidifying rotorHumidifying fan

Humidity absorb section

2.2.Sends moistureSends moistureThe humidifying rotor rotates to send the absorbed moisture to the moisture emission section.

1.Absorbs moisture

2.Rotates humidifying rotor

Page 12: Ver. 1.00

2006 New Products2006 New Products 06RAG12-12

Humidity Control

——Humidifying mechanismHumidifying mechanism——

3.3. Emits moisture Emits moistureIn moisture emission section, the absorbed moisture is emitted by heating humidifying rotor up. The moisture is mixed with the outdoor air to make highly humidified air.

Ventilation fan

Moisture emission section

4. 4. Sends the moisture to the roomSends the moisture to the roomThe emitted moisture is sent to the humidifying hose by the ventilation fan to be supplied to the room.

4. To the room via the humidifying hose

3.Heats up the rotor

Page 13: Ver. 1.00

2006 New Products2006 New Products 06RAG12-13

Humidity ControlHumidity Control

—— Re-heater dehumidifying Re-heater dehumidifying ——

Especially for rainy season

Refreshing without lowering the room temperature Refreshing without lowering the room temperature

Room temp.: 19°C Humidity: 50%You feel chilly because of dehumidifying by lowering room temperature.

With Re-heater dehumidifying

You feel cold

In the case of conventional dry operation In the case of Re-heater dehumidifying

Outdoor temp.: 22°C Humidity: 90% Refreshing and

comfortable

Room temp.: 22°C Humidity: 50% You feel comfortable because of dehumidifying without lowering room temperature.

Page 14: Ver. 1.00

2006 New Products2006 New Products 06RAG12-14

Humidity ControlHumidity Control

—— Effect of Re-heater dehumidifying Effect of Re-heater dehumidifying ——

Muggy

Lower humidity creates comfortable condition even at the same temperature.

Room temp.: 25°C Humidity: 80%You feel stuffy with high humidity.

Room temp.: 25°C Humidity: 50%You feel comfortable at the same temperature with lower humidity. The thermograph shows the temperature distribution of the skin

30 min. after entry into the room.

30.0 35.0 40.0°C

Refreshing and

comfortable

Page 15: Ver. 1.00

2006 New Products2006 New Products 06RAG12-15

Humidity ControlHumidity Control

——Re-heater dehumidifying mechanismRe-heater dehumidifying mechanism——

Re-heater Heat exchanger

Cooler

Dry and cold air (2)

Dry but not cold air (3)

Air warmedby re-heater (1)

Damp air Re-heaterRe-heaterDehumidifyingDehumidifyingOperationOperation

1.Cooling and dehumidifying the air extracted by cooler.

2.Heating up the extracted air by re-heater.

3. The dehumidified cool air (1) is mixed with the re-heated air (2) to be proper condition before sent to the room.

Page 16: Ver. 1.00

2006 New Products2006 New Products 06RAG12-16

Humidity ControlHumidity Control

——Re-heater dehumidifying mechanism Re-heater dehumidifying mechanism ——Puts a pressure reducing device (solenoid valve) in the center of the heat exchanger of Puts a pressure reducing device (solenoid valve) in the center of the heat exchanger of indoor unit to separate it into upper and lower side. The upper side acts as a condenser to indoor unit to separate it into upper and lower side. The upper side acts as a condenser to reheat the discharged air.reheat the discharged air.

Comp.

Indoor unitOutdoor unit

* Depends on the condition* Depends on the condition

openopen<<The current DRY operation>The current DRY operation>As is the cooling mechanism, the current As is the cooling mechanism, the current DRY operation rises latent heat capacity with DRY operation rises latent heat capacity with controlling sensible heat capacity by controlling sensible heat capacity by adjusting the compressor frequency and adjusting the compressor frequency and indoor air flow rate.indoor air flow rate.

close*close*

Compressor

Indoor unitOutdoor unit

Heat exchanger

Electronicexpansion valve

Solenoid valve for dehumidifying

Heat exchanger

openopen closeclose

Page 17: Ver. 1.00

2006 New Products2006 New Products 06RAG12-17

VentilationVentilation

—— Air Supply Ventilation Air Supply Ventilation ——

- Decomposes odors which can not be filtered out.

DraftShut out odors and dusts in the draft

Indoor Outdoor

Outdoor Unit Bad smells

and pollens

Outdoor air

formaldehyde,virus, mold fungus

Flash Streamer

Fresh and clean air

Photocatalytic air purifying filter

- Filters out pollens and dust

- Temperature control and air intakeAir supply filter

- Elimination of exhaust gases (NOx / SOx)

- Decomposition of bad smells

+Humidifyingrotor

Thermal catalyst

Indoor Unit

Contaminated outdoor air is purified through 2 stages of the outdoor unit and indoor unit.

Page 18: Ver. 1.00

2006 New Products2006 New Products 06RAG12-18

VentilationVentilation

—— Air Supply Ventilation Air Supply Ventilation ——

The air in a 26m2 room is replaced with “Fresh air” in 2 hours.

Fresh air

Airsupply

Powerful (32 mPowerful (32 m33/h /h at “High”at “High”) ventilation) ventilationby unique air supply system! by unique air supply system!

Page 19: Ver. 1.00

2006 New Products2006 New Products 06RAG12-19

VentilationVentilation

—— Internal Dry (Damp Discharging) Internal Dry (Damp Discharging) ——Dehydrates the inside of the indoor unit to inhibit the generation of mold and odor. Dehydrates the inside of the indoor unit to inhibit the generation of mold and odor. This operation continues for about 3 hours after the cooling operation is stopped.This operation continues for about 3 hours after the cooling operation is stopped.

<1. <1. Draining>Draining>Water accumulated in the drain pan is drained.

<2. <2. Internal dry> Internal dry> After draining water, water drops left in the drain pan and heat exchanger are evaporated and dehydrated by heating inside of the indoor unit.

<3. <3. Discharge of dampDischarge of damp > >The damp is discharged to outdoor through the humidifying hose.

The damp (evaporated by internal dry) is discharged to outdoor in the form of vapor. Since the sources of mold are discharged to outdoor, the inside of the indoor unit is kept always clean!

Page 20: Ver. 1.00

2006 New Products2006 New Products 06RAG12-20

VentilationVentilation

—— Technology Technology ——

- Air supply and exhaust through the humidification hose

- Controlling air supply and exhaust by the damper in the outdoor unit.

Air supplyposition

Air exhaustposition

About air supply & exhaust functions

Ventilation fan Ventilation fan

Page 21: Ver. 1.00

2006 New Products2006 New Products 06RAG12-21

Air-purifyingAir-purifying

—— Flash Streamer Flash Streamer ——

Flash streamer improves air purify performance!

Powerful air purifying with Flash streamer technology which has been adapted on the DAIKIN Air purifier.

Flash Streamer Unit

Flash Streamer UnitFlash Streamer Unit

Page 22: Ver. 1.00

2006 New Products2006 New Products 06RAG12-22

Air-purifyingAir-purifying

—— Flash Streamer Flash Streamer ——

Terminal unit Streamer discharge

Deodorizing filter

Pre-filter

New air purify method with streamer

Powerfully decompose and remove molecules of allergens or odors by collision with high-speed electrons discharged from streamer unit.

Over 1000 times faster than Over 1000 times faster than plasma discharge!plasma discharge!

Streamer discharge gets 1000 times faster oxidize decompose speed than the most common type of plasma(glow) discharge does while using the same amount of electrical power.

Air purify flow

Page 23: Ver. 1.00

2006 New Products2006 New Products 06RAG12-23

Air-purifyingAir-purifying

—— Flash Streamer Flash Streamer ——

CigaretteCigarette PetPet

BathroomBathroom MoldMold

FishFish EggEgg

CookingCooking GarbageGarbage

20

0

40

60

80

100

Persist

rate(

%)Time (min.)

5 10 15

●Removal rate of lifestyle related odor. (%)

Ammonia : Pet odor ・ Bathroom odor

Trimethlamine : Fish odor

Methyl Mercaptane : Garbage odor ・ Rot odor

Hydrogen Sulfide : Egg odor

Quick deodorizingQuickly remove ingredients of odor

Naturally removed

Over 90% removed

in approximately 10 min.

※ Persist rate of odor ingredients in a box of 1 m 3, operating FTXR42E ( Daikin result )

Page 24: Ver. 1.00

2006 New Products2006 New Products 06RAG12-24

Air-purifyingAir-purifying

—— Mold Shock Operation Mold Shock Operation ——

Mold spores is destroyed when reducing the room humidity by half and keep the conditions for 3 hours.Reported by Environment Biologic laboratory Prof. Keiko Abe at International Congress.  

Shut out mold and mite

from a room by a sudden fall of room humidity!

This function is to control the growth of mold by lowering the humidity quickly dehumidifying for 3 hours continuously.

In general, growth of mold can be controlled under the condition of below 60% in

humidity.

Growth image of mold

Mechanism of Mold Shock Operation

Mold Shock startMold Shock start

Mold Shock ON

Create an environment where mold can hardly grow by a sudden fall of

room humidity!

Mold Shock OFF

Time

The hypha lengthwhich a sporegerminates

Mold

Page 25: Ver. 1.00

2006 New Products2006 New Products 06RAG12-25

Energy SavingEnergy Saving

—— Energy Saving Energy Saving ——

Capacity Capacity classclass Model nameModel name

COPCOP

CoolingCooling HeatingHeating

2.82.8kWkW FTXR28EFTXR28E 4.75 / 4.75 / AA 4.59 / 4.59 / A A

4.24.2kWkW FTXR42EFTXR42E 3.68 / 3.68 / AA 3.81 / 3.81 / AA

5.05.0kWkW FTXR50EFTXR50E 3.23 / 3.23 / AA 3.64 / 3.64 / AA

All "A" EER LabelAll "A" EER Label

Page 26: Ver. 1.00

2006 New Products2006 New Products 06RAG12-26

Energy SavingEnergy Saving

—— Technology Technology ——

Swing Compressor

Adopted cylinder structure less liable to heat-transfer loss and deformation.

New swing compressorFurther energy-savings with improvement of motor and compression efficiency.

Reluctance DC Motor

Heat transfer coil: Distributed roll

Concentrated rollThe heat loss is reduced.

Neodymium magnet:4 pieces to 6 pieces.Rotation of motor gets more smooth.

Rotor part

Stator part

Neodymium magnet

Distributed roll

Current New

Current New

Concentrated roll

Page 27: Ver. 1.00

2006 New Products2006 New Products 06RAG12-27

Energy SavingEnergy Saving—— Technology Technology ——

Standard air outlet grille New twist grilleRight sideRight side Left sideLeft side

Twisted the grille to make the air flow from outdoor unit fan Twisted the grille to make the air flow from outdoor unit fan smooth and lessen the air flow resistance.smooth and lessen the air flow resistance.It resulted in further energy savings.It resulted in further energy savings.

Right sideRight side Left sideLeft side

Not efficient because of air flow resistance caused by horizontal grille.

Highly efficient with the less air flow resistance by twisting left and right side of the grille respectively to be parallel with air flow.

Page 28: Ver. 1.00

2006 New Products2006 New Products 06RAG12-28

Energy SavingEnergy Saving

—— Technology Technology ——Compact size : Depth Compact size : Depth 198198mmmm (( when it is not operatingwhen it is not operating ))Achieved high COP with Slide Opening System and Saw Edge FanAchieved high COP with Slide Opening System and Saw Edge Fan

Not operatingNot operating

OperatingOperating

Slide Opening SystemSlide Opening System

Slide opening system of front Slide opening system of front panel maintains a enough panel maintains a enough volume of air inlet during volume of air inlet during operation.operation.

Saw Edge FanSaw Edge Fan

The indentation of the fan The indentation of the fan blade reduces the air flow blade reduces the air flow resistance. Achieves both the resistance. Achieves both the operation sound decrease operation sound decrease and the air flow increases.and the air flow increases.

Page 29: Ver. 1.00

2006 New Products2006 New Products 06RAG12-29

Comfortable AirflowComfortable Airflow

—— Flap Control Flap Control ——

UpwardUpward DownwardDownward ClosedClosed

< Two horizontal flaps are controlled independently >

Two flaps move only horizontally.

Panel image during operation

Two flaps move independently.

a.Slide opening panel motorb.Horizontal flap motor 1c.Horizontal flap motor 2d.Vertical flap motor

Air flow control with 4 different motors.

Conventional model New model

a

b,c d

Page 30: Ver. 1.00

2006 New Products2006 New Products 06RAG12-30

Comfortable AirflowComfortable Airflow

—— Comfortable Mode Comfortable Mode ——Realizing the fine and efficient air flow control by controlling two Realizing the fine and efficient air flow control by controlling two horizontal-flaps independently.horizontal-flaps independently.

CoolingCooling

HeatingHeating

The warm air reaches the floor.

Upward air flow without air flow loss.

Current model

Current model

New model

New model

Air flow is spread out!

Air flow is spread out!

NOT spread out!

NOT spread out!

Page 31: Ver. 1.00

2006 New Products2006 New Products 06RAG12-31

Comfortable AirflowComfortable Airflow

—— Long Distance Airflow (Heating) Long Distance Airflow (Heating) ——

100 200 300 400 500 600 700 800 900 1000

5

100

190

9m 5 cm above the floor 24.5℃10m 5 cm above the floor 23.6℃

<Test conditions>Outdoor temp.: 2°C R/C setting: 23°C, “Powerful” 30 min. later the operation is started. Test room : 32.4m2 Test model :FTXR40E

Create comfort Create comfort in large space in large space such as large such as large living roomliving room

Hei

ght

(cm

)

Distance (cm)

Page 32: Ver. 1.00

2006 New Products2006 New Products 06RAG12-32

Easy ControlEasy Control

——Two-way communication remote controllerTwo-way communication remote controller——

New remote controller can New remote controller can control various functions.control various functions.

The buttons of frequent use are The buttons of frequent use are placed on the surface of the placed on the surface of the controller cover. The others are controller cover. The others are under the cover. under the cover.

The two-way communication The two-way communication between the controller and the between the controller and the indoor unit enables the indoor unit enables the controller to display the present controller to display the present temperature and humidity.temperature and humidity.

Under the coverUnder the cover

Page 33: Ver. 1.00

2006 New Products2006 New Products 06RAG12-33

Easy ControlEasy Control

—— Direct Mode Buttons Direct Mode Buttons ——

The operation modes used The operation modes used frequently, Cooling, Heating, frequently, Cooling, Heating, Humidifying and Humidifying and Dehumidifying are assigned Dehumidifying are assigned to each special button placed to each special button placed on the surface of the on the surface of the controller. You can set each controller. You can set each mode by just one push.mode by just one push.

Easy Easy OFF timerOFF timer

CoolingCooling

DehumidifyingDehumidifying

HeatingHeating

HumidifyingHumidifying

AutomaticAutomaticOperationOperation

Page 34: Ver. 1.00

2006 New Products2006 New Products 06RAG12-34

Easy ControlEasy Control

—— Temp. & Humidity Indication Temp. & Humidity Indication ——

I.D&O.D Temperature display I.D&O.D Temperature display The present indoor and outdoor temperature is The present indoor and outdoor temperature is

shown on a remote controller display when shown on a remote controller display when pushing the "info" button. It is economic if you pushing the "info" button. It is economic if you change the set temperature appropriately change the set temperature appropriately according to the information.according to the information.

Humidity displayHumidity display The indoor humidity is displayed by 5% on a The indoor humidity is displayed by 5% on a

remote controller when pushing the "info" remote controller when pushing the "info" button. By controlling humidity properly button. By controlling humidity properly according to the information, you can prevent according to the information, you can prevent the growth of mold and mite.the growth of mold and mite.

Indoor Indoor temperature temperature and humidity and humidity displaydisplay

Outdoor Outdoor temperature temperature displaydisplay

Onepush

After 10 sec.or one more push

Page 35: Ver. 1.00

2006 New Products2006 New Products 06RAG12-35

Variable FunctionsVariable Functions

—— Other Functions Other Functions ——Power-airflow dual flapsPower-airflow dual flaps

Control air flow with two guide flaps, bring a cold Control air flow with two guide flaps, bring a cold or warm air(depends on a season) to every part or warm air(depends on a season) to every part of a room. Even to foot. When the air-conditioner of a room. Even to foot. When the air-conditioner does not work, it gives you a stylish sense of does not work, it gives you a stylish sense of design because the flaps are closed tight. design because the flaps are closed tight.

((Breeze cooling airflow)Breeze cooling airflow)

In addition to comfortable air flow control by In addition to comfortable air flow control by Power-airflow dual flaps, shake an air direction Power-airflow dual flaps, shake an air direction in 1/f rhythm, which makes you feel cool without in 1/f rhythm, which makes you feel cool without lowering the temperature. Rising the setting lowering the temperature. Rising the setting temperature gives a thought for women and high temperature gives a thought for women and high energy-saving efficiency.energy-saving efficiency.

Power-airflow louversPower-airflow louvers

The smoothly curved Wide-Angle louvers The smoothly curved Wide-Angle louvers provide wide airflow coverage for effective provide wide airflow coverage for effective cooling/heating.cooling/heating.

3-3-D airflowD airflow

This function combines Vertical and Horizontal This function combines Vertical and Horizontal Auto-Swing to circulate a cloud of cool/warm air Auto-Swing to circulate a cloud of cool/warm air right to the corners of even large spaces.right to the corners of even large spaces.

Indoor unit silent operationIndoor unit silent operation

Indoor unit operating sound levels are Indoor unit operating sound levels are decreased by air flow control [Silent] while your decreased by air flow control [Silent] while your children are studying, or reading a book at the children are studying, or reading a book at the night time.night time.

Moisturizing operationMoisturizing operation

Operate the following three functions at the Operate the following three functions at the same time to create a kind condition for your same time to create a kind condition for your skin. "High humid" setting, "Comfortable skin. "High humid" setting, "Comfortable operation" and supply Vitamin and Hyaluronic operation" and supply Vitamin and Hyaluronic acid ingredients.acid ingredients.

Note)Moisturizing operation is only for create a Note)Moisturizing operation is only for create a kind room condition for your skin under the kind room condition for your skin under the cooling, heating, dry and humid operation. This cooling, heating, dry and humid operation. This is not for beauty treatment, Whitening or rough is not for beauty treatment, Whitening or rough skin.skin.

Page 36: Ver. 1.00

2006 New Products2006 New Products 06RAG12-36

Variable FunctionsVariable Functions

—— Other Functions Other Functions ——Washable upper grilleWashable upper grille

You can remove the upper grille gets dust easily You can remove the upper grille gets dust easily and wash it.and wash it.

((Rainbow-colored multi monitor)Rainbow-colored multi monitor)

The changeable in 6~8 colors indoor unit light The changeable in 6~8 colors indoor unit light shows you the operation mode by color. You shows you the operation mode by color. You can easily know the operation mode even during can easily know the operation mode even during the automatic operation mode.(The colors of the automatic operation mode.(The colors of light are linked with the colors of direct buttons light are linked with the colors of direct buttons on remote controller )on remote controller )

((Indoor unit indication ON/OFF setting)Indoor unit indication ON/OFF setting)

You can turn off the multiple monitor and You can turn off the multiple monitor and operation light on the body of air-conditioner. It operation light on the body of air-conditioner. It is convenient when you feel it is too bright such is convenient when you feel it is too bright such as night time.(There are 3 steps: as night time.(There are 3 steps: Bright~Dark~Off)Bright~Dark~Off)Wipe-clean flat panelWipe-clean flat panel

The flat panel can be cleaned with only the The flat panel can be cleaned with only the single pass of a cloth across their smooth single pass of a cloth across their smooth surface. The flat panel can also be easily surface. The flat panel can also be easily removed for more thought cleaning.removed for more thought cleaning.

((Mold proof stick)Mold proof stick)

Set "Stick" which has antibacterial (mold proof) Set "Stick" which has antibacterial (mold proof) ingredient and it comes out little by little in a ingredient and it comes out little by little in a heat exchanger or drain pan. heat exchanger or drain pan.

((Comfort sleep operation)Comfort sleep operation)

Control original V shape temperature by about Control original V shape temperature by about ±2°C range. Lower the indoor temperature ±2°C range. Lower the indoor temperature slowly as you fall asleep to promote your body slowly as you fall asleep to promote your body temperature gets lowered. Keep the same room temperature gets lowered. Keep the same room temperature until the hour of rising you set. temperature until the hour of rising you set. Raise the room temperature as you wake up to Raise the room temperature as you wake up to promote your body temperature is raised before promote your body temperature is raised before waking up. waking up.

Page 37: Ver. 1.00

2006 New Products2006 New Products 06RAG12-37

Variable FunctionsVariable Functions

—— Other Functions Other Functions ——Self - diagnosis (R/C) displaySelf - diagnosis (R/C) display

Malfunction codes for each indoor unit are Malfunction codes for each indoor unit are shown on the digital display panel of the shown on the digital display panel of the wireless remote controller for fast and easy wireless remote controller for fast and easy maintenance.maintenance.

((Home leave ventilation)Home leave ventilation)

Setting ventilation programme operation allows Setting ventilation programme operation allows you to ventilate a room while you are out of your you to ventilate a room while you are out of your home. This particularly useful during summer home. This particularly useful during summer when rooms quickly become stuffy.when rooms quickly become stuffy.

((Night set mode)Night set mode)

Cooling operation: Raise the room temperature Cooling operation: Raise the room temperature by 0.5°C an hour later from the first turn on to by 0.5°C an hour later from the first turn on to prevent from being too cold. prevent from being too cold.

Cooling, Dehumidifying operation: Lower a Cooling, Dehumidifying operation: Lower a humidity by15% for an first an hour and half to humidity by15% for an first an hour and half to keep your comfort.keep your comfort.

Heating operation: Operate in lower temperature Heating operation: Operate in lower temperature and energy-saving humidifying to prevent from and energy-saving humidifying to prevent from sweating of window or wall. This turns on sweating of window or wall. This turns on automatically when off timer operates.automatically when off timer operates.

Anticorrosion treatment of outdoor heat Anticorrosion treatment of outdoor heat exchangerexchanger

Special anticorrosion treatment of the outdoor Special anticorrosion treatment of the outdoor unit heat exchanger fin gives 5 to 6 times unit heat exchanger fin gives 5 to 6 times greater resistance against acid rain and salt greater resistance against acid rain and salt corrosion.corrosion.

Page 38: Ver. 1.00

2006 New Products2006 New Products 06RAG12-38

SpecificationsSpecifications

2.8kW class2.8kW class 4.2kW class4.2kW class 5.0kW class5.0kW class

Capacity (kW)Capacity (kW) CoolingCooling 2.8 (2.8 (Max. 3.6)Max. 3.6) 4.2 (4.2 (Max. 4.6)Max. 4.6) 5.0 (5.0 (Max. 5.5)Max. 5.5)

HeatingHeating 3.6 (3.6 (Max.4.8)Max.4.8) 5.1 (5.1 (Max. 5.6)Max. 5.6) 6.0 (6.0 (Max. 6.2)Max. 6.2)

COP (W/W)COP (W/W) CoolingCooling 4.75/4.75/AA 3.68 / 3.68 / AA 3.23 / 3.23 / AA

HeatingHeating 4.56/4.56/AA 3.80 / 3.80 / AA 3.64 / 3.64 / AA

Indoor UnitIndoor Unit FTXR28EV1BFTXR28EV1B FTXR42EV1BFTXR42EV1B FTXR50EV1BFTXR50EV1B

Dimensions (HxWxD)Dimensions (HxWxD) 305305x890x209x890x209

Operation Sound Operation Sound (dBA) (H)(dBA) (H)

CoolingCooling 3939 4242 4444

HeatingHeating 4141 4242 4444

Outdoor UnitOutdoor Unit RXR28EV1BRXR28EV1B RXR42EV1BRXR42EV1B RXR50EV1BRXR50EV1B

Dimensions (HxWxD)Dimensions (HxWxD) 693693x795x285x795x285

Operation Sound Operation Sound (dBA)(dBA)

CoolingCooling 4646 4848 4848

HeatingHeating 4646 4848 5050

Operation Limit Operation Limit (Cooling/Heating)(Cooling/Heating)

21~4321~43°CDB / °CDB / -20~24-20~24°CWB°CWB

Power Supply: 50Hz 220-240V—— Main Specifications Main Specifications ——