Water Filter S · Web viewHYDRAVERT® consists of 1 motorized central one-inch brass ball valve...

15
INSTRUCTION MANUAL INSTRUCTIEHANDLEIDING MANUEL D’UTILISATION

Transcript of Water Filter S · Web viewHYDRAVERT® consists of 1 motorized central one-inch brass ball valve...

Page 1: Water Filter S · Web viewHYDRAVERT® consists of 1 motorized central one-inch brass ball valve with manual override and 6 wireless R/F battery-operated discs and 1 central main control

INSTRUCTION MANUALINSTRUCTIEHANDLEIDINGMANUEL D’UTILISATION

HANDBUCH

Page 2: Water Filter S · Web viewHYDRAVERT® consists of 1 motorized central one-inch brass ball valve with manual override and 6 wireless R/F battery-operated discs and 1 central main control

L

MP

K

O

N

Q

R

S

AB

Automatic positionA

B

AB

ManualpositionA

BManualposition

MANUAL DE INSTRUCCIONESMANUALE ISTRUZIONI

BRUKSANVISNINGКерівництво з експлуатації

BD

C

F

GE

H

I

J

A

N

O

M

S

T

U

Page 3: Water Filter S · Web viewHYDRAVERT® consists of 1 motorized central one-inch brass ball valve with manual override and 6 wireless R/F battery-operated discs and 1 central main control

ENGLISHA : big wheelB : small wheelC : “open” buttonD : “close” buttonE : “reset” buttonF : adaptor insertG : valveH : tamper fraud labelI : battery coverJ : antennaK : LCD screen L : red ledM : touch backlight buttonN : green ledO : adaptor insertP : “open” buttonQ : “close” buttonR : “holiday” buttonS : “reset” button

NEDERLANDSA : groot wielB : klein wielC : toets ”openen”D : toets ”sluiten”E : toets ”reset“F : elektrische ingangG : kraanH : garantie etiketI : batterij deurJ : antenneK : LCD schermL : rode ledM : scherm verlichtingN : groene ledO : elektrische ingangP : toets ”openen”Q : toets ”sluiten”R : toets “vakantie”S : toets “reset”

FRANCAISA : grande moletteB : petite moletteC : bouton ”ouvrir”D : bouton ”fermer”E : bouton “reset”F : insertion électriqueG : valveH : étiquette de garantieI : couvercle pour pilesJ : antenneK : écran LCDL : témoin rougeM : éclairage écranN : témoin vertO : insertion électriqueP : bouton”ouvrir”Q : bouton ”fermer”R : bouton ”vacances”S : bouton “reset”

DEUTCHA : grosses RadB : kleines RadC : Taste ”öffnen“D : Taste “schliessen”E : Taste “reset”F : AdaptereinsatzG : VentilH : manipulationssicherer AufkleberI : BatterieabdeckungJ : AntenneK : Bildschirm LCDL : rote LedM : Taste für

Hintergrundbeleuchtung N : grüne LedO : AdaptereinsatzP : Taste ”öffnen“Q : Taste “schliessen”R : Taste ”Urlaub“S : Taste ”reset“

ESPAÑOLA : rueda grandeB : rueda pequeñaC : botón “abrir”D : botón “cerrar” E : botón “reset”F : conexión alimentadorG : válvulaH : etiqueta a prueba de manipulaciónI : tapa compartimento de pilasJ : antenaK : pantalla LCDL : led rojoM : tecla de luz de fondo N : led verdeO : Conexión adaptorP : botón “abrir”Q : botón “cerrar”R : botón “vacaciones”S : botón “reset”

ITALIANOA : volantino grandeB : volantino piccoloC : pulsante “aprire”D : pulsante “chiudere”E : pulsante ”reset“F : inserto adattatoreG : valvolaH : etichetta inviolabileI : coperchio batteriaJ : antennaK : schermo LCDL : led rossoM : pulsante retroilluminato a sfioramentoN : led verdeO : inserto adattatoreP : pulsante “aprire”Q : pulsante “chiudere”R : pulsante “vacanza”S : pulsante “reset”

ENGLISHHYDRAVERT®The whole house water protection solution! HYDRAVERT®, a smart home leak detection and water control system, protecting your entire home with 1 single system.It is a fully wireless, automatic operated unit that closes the central main water supply.HYDRAVERT® consists of 1 motorized central one-inch brass ball valve with manual override and 6 wireless R/F battery-operated discs and 1 central main control box with Graphics LCD screen.The system indicates when battery replacement is needed, where water damage may be occurring, will run self-tests and features a special ‘Holiday” function for long periods of absence.Whenever there is a leak, it will shut the main water supply, making it your best whole house water protection solution, equipped with the latest technologies.These units are Tamper protected and Code Encrypted

Product features:- fully automatic wireless R/F unit- battery and electrical operated- 1 motorized one-inch full port brass ball valve BSP (incl. NPT fittings = only in case of USA/CANADA version)- manual override on valve- 6 wireless discs- 1 controller unit with LCD screen- low battery indication- runs self-tests- holiday function- audible and visual alarm indication- easy installation

Where to use:HYDRAVERT® water discs are meant to be installed next to all critical water appliances that are a danger to your home in general.Place the water discs near to the water heater (boiler), dishwasher, washing machine, sinks, osmoses units, lavatories, refrigerator, water filtration systems, toilets, water softener, fish tank, house plants, basement, garage, sump pump or anywhere hoses or pipes are under pressure, or might freeze or break.For maximum protection, it is recommended that you place the unit under, or near, each such appliance or potential area or leaks.The valve is placed on the central main water entry, and the main control box is to be installed either in the kitchen or garage, but preferably centralised AND ONLY on the ground floor in the home.Important: (for apartments it is recommended to connect the valve to the main water entry coming into the apartment on the same floor).

Page 4: Water Filter S · Web viewHYDRAVERT® consists of 1 motorized central one-inch brass ball valve with manual override and 6 wireless R/F battery-operated discs and 1 central main control

The system could not be applicable in case of passing several floors between the valve and main control box. (the connection between these two components needs to be excellent).

Product codes: HYDRAVERT® Part no. HV-6S-01-EC (Europe) with 1” BSP VALVE HYDRAVERT® Part no. HV-6S-01-US (USA/CANADA) with 1” BSP VALVE (Includes 2 fittings 1” NPT Female Adaptors)

Menu:A) FIRST TIME ACTIVATION

a. If you see “OK” on the LCD screen next to the word “valve”b. If you DO NOT see “OK” on the LCD screen next to the word “valve”

B) SYSTEM FUNCTIONS AND PROBLEMS1) WATER ALARM2) LOW BATTERY (CRITICAL)

a. Putting a NEW batteryb. NO batteries at handc. Disconnecting the electricity

POSSIBILITY 1 POSSIBILITY 2

3) POWER FAILURE/SHUT OFF/FALL OUTa. If the valve is on battery supply (ONLY)b. If the valve is on electric supply

4) DISC MISSING, BROKEN, MALFUNCTIONING OR OUT OF REACH SOLUTIONS

a. RETRYb. ACCEPT

5) VALVE MANUAL OVERRIDE/MANUAL POSITION6) SELF TEST7) HOLIDAY

a. Holiday ONb. Holiday OFF

8) “CLOSE” AND “OPEN” BUTTONa. CLOSEb. OPEN

9) VALVE MALFUNCTIONa. SOLUTION 1b. SOLUTION 2

C) IMPORTANT POINTS OF USE1) MAINTENANCE2) IMPORTANT NOTICE3) TECHNICAL DESCRIPTIONS

A) FIRST TIME ACTIVATION: (Please follow STEP BY STEP, and use the drawings inside the instruction manual).- unwrap the items out of the packaging.You will find:

1 valve 1 main control box with LCD screen 6 discs 2 universal world adapters with each 3 interchangeable plugs switching EC/UK/USA connectors 4 (AA 1.5V Alkaline) batteries 6 (CR123A 3V Lithium) batteries 2 valve fittings (only in case of USA/CANADA version) 1 plastic bag with mounting hardware (plugs and screws) for main control box 1 long “big” straight screw model antenna (for the valve) to be used as first choice 1 extra L-type screw model antenna (for the valve) to be used as seconds choice (in case of “Bad transmitting” cellars) 1 user guide

Instructions and Installation: (the use of a professional plumber is recommended)- Do NOT connect electricity, and do NOT apply batteries to any item.- Turn off the main water supply to the home.- Mount the valve section on the main water supply entering the home, but do NOT connect electricity, and do NOT apply batteries. (the main water supply can be found either in the cellar (basement), or garage)- Place the antenna on the valve (ONLY the long “big” straight screw model antenna)- Make sure that the small wheel (LIFT UP AND TURN) on top of the valve is on automatic position.- Take the main control box and place it as close as possible to the valve, BUT on the ground floor ONLY. (for example the kitchen, laundry room or garage). The ground floor is NOT the cellar or basement!- Open the hinged door on the main control box and you will find 4 buttons:

Open * (green button) Close # (red button) Holiday (orange button) Reset (yellow button)

- NOW apply ONLY electricity to the main control box.

(IF NO TEXT IS SHOWING , THEN DISCONNECT THE ELECTRICITY FROM THE MAIN CONTROL BOX AND RE-CONNECT IMMEDIATELY)

The LCD screen is firstly blank, and will then show:Push RESET

To Enter Teach ModeOR

Page 5: Water Filter S · Web viewHYDRAVERT® consists of 1 motorized central one-inch brass ball valve with manual override and 6 wireless R/F battery-operated discs and 1 central main control

WAIT forAutomatic Mode

- NEW USER press “RESET” (yellow button).(If you push RESET then you are a NEW user = first time installation, and this means “Teach Mode” will be selected) = (you ONLY have 20 seconds to confirm!!!)- Then LCD screen will show:

Entering Teach ModeConfirm?

Accept *Cancel #

- Press “Accept *” (green button), and then LCD screen will show:Insert Batteries

Into Discs One AfterThe Other+ Connect

Electricity To Valve- Now put electricity to the valve ONLY, but do NOT put batteries into the discs, and do NOT put batteries inside the valve.- Go back to the main control box and follow the next steps:

a) If you see “OK” on the LCD screen next to the word “valve”:- The LCD screen should show “OK” next to the word “valve” as following:

Disc 1: Disc 6: Disc 2: Valve: okDisc 3: Disc 4: Accept *Disc 5: Retry #

- If you see “OK” next to the word “valve”, then this means the wireless connection between the main control box, and the valve is strong enough. (this also means that you must keep that distance equal for perfect reception, and so that you DO NOT enlarge afterwards that distance when hanging the main control box on a wall)- If you do want to enlarge that distance, then you need to repeat the whole process.

b) If you DO NOT see “OK” on the LCD screen next to the word “valve”:- Change the long “big” straight antenna on the valve, and screw on the short “small” straight antenna, and repeat (*) the whole process.

(*) The whole process means: disconnect the electricity from the valve + change the antenna on the valve + disconnect the electricity from the main control box + reconnect immediately + push RESET + ACCEPT to enter teach mode + go back to the valve and reconnect the electricity + check the main control box LCD screen.

- If then the LCD does NOT show “OK” next to the word “valve”, then you need to shorten the distance between the valve and the main control box, FIRST with the long “big” straight antenna on the valve, and repeat (*) the whole process, and if STILL NOT “OK”, try with the short “small” straight antenna.

IT IS IMPORTANT THAT THE COMMUNICATION BETWEEN VALVE AND MAIN CONTROL BOX IS EXCELLENT BEFORE PROCEEDING FURTHER!!!

THEN AND ONLY THEN proceed with the following action:- Hang with the supplied mounting hardware the main control box on a wall. (if you disconnected the electricity from the main control box because of hanging it to the wall, then you need to repeat the whole process again).

- INSERTING THE BATTERIES INSIDE THE DISCS:- Take the 6 discs, put them together, turn them all open and place the supplied (CR123A 3V Lithium) batteries inside each one of them, and a RED LED will flash inside each disc, confirming activation and reception. (you need to see the RED LED flash, as otherwise take the battery out, and wait 5 seconds before re-inserting the battery).Important: If you wish to use less discs then only add batteries in the ones you need, and put away the ones you do not need.

- Go to the main control box and you will see “OK” appear one by one next to each disc, as following:Disc 1: ok Disc 6: okDisc 2: ok Valve: okDisc 3: ok Disc 4: ok Accept *Disc 5: ok Retry #

- If this is the case then this means the discs made a connection with the main control box. (if not then press “Retry #”, and remove the battery out from the disc that doesn’t appear “OK”, and re-insert the battery after 5 seconds).You can find the number on the backside of the disc.If all discs have been found, then:- Press “Accept *” (green button), and the LCD screen will show:

…SAVING SETTINGS…Then LCD screen will show:

Page 6: Water Filter S · Web viewHYDRAVERT® consists of 1 motorized central one-inch brass ball valve with manual override and 6 wireless R/F battery-operated discs and 1 central main control

SETTINGS SAVEDThen LCD screen will show:

SYSTEM INITIALIZINGThen LCD screen will show:

WAITING FOR…VALVE RESETTING…

Then LCD screen will show: ...VALVE RESETTING…

Then LCD screen will show:VALVE OPEN–WATER OKAY

SYSTEM STATUS OKAYThen LCD screen will show:

HYDRAVERT LOGOwater detecting system

The GREEN LED on the valve will light-up continuously.The GREEN LED on the main control box will light up continuously, and the LCD backlight will turn off in 30 seconds.

next steps:- Look on the back side of the discs, and you will find a number from 1 to 6.- You will find a label on the back of the hinged door on the main control box, mentioning 1 to 6, and write next to each number where you will put that disc. (for example: water heater, washing machine, dishwasher, under the sink, cellar, water softener, etc…).- Now put all 6 discs near to those critical areas for water damages, according to your list.- Go to the valve, and add the (4 AA 1.5V Alkaline) batteries as back-up, but leave the valve on electricity! (we recommend that you apply electricity to the valve at all times).- Open your main water supply to the home and check for leaks.- Your installation is finished and your system is now fully operational and armed (you are now protected against water damages)BACKLIGHT: EACH TIME YOU WISH TO LIGHT UP THE MAIN CONTROL BOX BACKLIGHT = TOUCH THE LABEL MENTIONING “TOUCH BACKLIGHT” (between the RED and GREEN LED)

B) SYSTEM FUNCTIONS AND PROBLEMS:

There are 3 buttons on the valve:1. OPEN with a GREEN LED ( the Green LED is always on when valve is open). 2. CLOSE with a RED LED ( the Red LED is always on when valve is closed). 3. RESET (here there is NO LED).

There are 5 buttons on the main control box:Button 1: Open * Button 2: Close # Button 3: HolidayButton 4: ResetButton 5: Touch Backlight + the unit has 2 LED’S: RED and GREEN

1) WATER ALARM:

- When 1 or more discs touch water then the main control box will immediately send a signal to close the valve.- The RED LED on the disc will light-up whenever a water leakage is detected, and the RED LED will blink every 4 seconds indicating transmission (max. 10 times)- Once the disc unit receives acknowledgement, then the RED LED goes OFF immediately, and if not it keeps blinking every 4 seconds for not more then 10 times.- The valve will show a RED LED light on top of the valve.- The LCD screen on the main control box will light up continuously + sound a buzzer as (beep…beep…beep = 3 times every 12 seconds).- The RED LED on the main control box will flash continuously.The LCD screen will show:

WAITING FOR…VALVE CLOSING…

Then LCD screen will show:…VALVE CLOSING…

Then LCD screen will show:WATER ALARM !

Disc(s): …VALVE CLOSED-NO WATER

PROBLEM SOLVED?PUSH RESET

- The LCD screen will show the disc with water alarm, or more discs with water alarm.- To know where the disc(s) with water alarm is situated, open the hinged door on the main control box and look on the back side of that hinged door to know where you placed that disc.- Go to that area and check the problem.(It might be that you will find very little water, as the valve reacted very fast, and the damage might be minor, so check under the disc).- if the damage seems unsolvable by yourself, then call a professional plumber.- If you feel the problem is solved, then clean up the water + clean the disc with a dry cloth + open the disc and remove the battery, and re-insert the battery after 5 seconds, showing a RED LED flash inside the disc confirming activation and reception., and then put the disc back into place. (you need to see the RED LED flash, as otherwise re-insert the battery)-Then go back to the main control box, and follow the instructions on the screen by pressing “RESET”

Page 7: Water Filter S · Web viewHYDRAVERT® consists of 1 motorized central one-inch brass ball valve with manual override and 6 wireless R/F battery-operated discs and 1 central main control

The LCD screen will show:WAITING FOR

…VALVE RESETTING…The LCD screen will show:

...VALVE RESETTING…Then LCD screen will show:

VALVE OPEN–WATER OKAYSYSTEM STATUS OKAY

Then LCD screen will show:HYDRAVERT LOGO

water detecting system- The RED LED on the valve will go back to GREEN.- The main control box flashing RED LED will go back to GREEN.- Your system is now AGAIN fully operational and armed, and you are now AGAIN protected against water damages.

2) LOW BATTERY (CRITICAL):

When the critical level of the battery is reached, then the disc(s) or the valve will send out a continuous signal to alert the main control box.When 1 or more discs or the valve have “critical” low battery then the LCD screen on the main control box will enlighten for 30 seconds + sound a small “friendly” 3 beep (beep…beep…beep) every 30 minutes. (It is recommended that you apply ONLY electricity to the valve).The RED LED on the main control box will flash continuously.The valve will remain open, but the LCD screen will show:

Critical low batteryDisc(s): …

REPLACE BATTERY- To know where the disc(s) is situated, open the hinged door on the main control box and look on the back side of that hinged door to know where you placed that disc.

a) Putting a NEW battery:-Open the disc, and place a new (CR123A 3V Lithium) battery, and a RED LED will flash inside the disc, confirming activation and reception. (the RED LED inside the disc must flash)- Close the disc and place it back.- You will see that the LCD screen on the main control box self adjusted and acknowledged acceptance of a new battery, and the LCD screen will show:

HYDRAVERT LOGOwater detecting system

- The main control box flashing RED LED will go back to GREEN.- The system is now back in normal functional mode.IMPORTANT:(If there are more discs with low battery then the LCD screen will show multiple numbers, so when changing for example the battery inside disc 4, then 4 will automatically disappear from that list and the next discs will appear on the LCD screen, until each battery is replaced). b) NO batteries at hand:If the user doesn’t replace the battery(s), the LCD screen will show same info until replaced.(If the user wants to stop the buzzer, then press “RESET”, but if the batteries are not replaced, then the system will go back to alarm mode after 30 minutes).c) Disconnecting the electricity:If the user has NO batteries then he might unplug the electricity from the main control box, to stop the sound of the buzzer.DO NOT DO THAT, as the valve will automatically close itself after maximum 25 minutes because it lost communication with the main control box.

The user has therefore 2 possibilities:POSSIBILITY 1:He can put back the electricity to the main control box, and then the following will start, BUT the user MAY NOT PRESS ANY BUTTONS!!!(IF NO TEXT IS SHOWING , THEN DISCONNECT THE ELECTRICITY FROM THE MAIN CONTROL BOX AND RE-CONNECT IMMEDIATELY)The LCD screen is firstly blank, and will then show:

Push RESETTo Enter Teach Mode

ORWAIT for

Automatic Mode

IMPORTANT: DO NOT PUSH ANY BUTTONS AND WAIT AS THE SYSTEM WILL SET ITSELF BACK TO ITS ORIGINAL MEMORY AFTER 20 SECONDS.

Then LCD screen will AUTOMATICALLY show:SYSTEM INITIALIZING

Then LCD screen will show: WAITING FOR

…VALVE RESETTING…Then LCD screen will show:

Page 8: Water Filter S · Web viewHYDRAVERT® consists of 1 motorized central one-inch brass ball valve with manual override and 6 wireless R/F battery-operated discs and 1 central main control

...VALVE RESETTING…Then LCD screen will show:

VALVE OPEN–WATER OKAYSYSTEM STATUS OKAY

Then LCD screen will show:HYDRAVERT LOGO

water detecting systemThe GREEN LED on the valve will light-up continuously.The GREEN LED on the main control box will light up continuously, and the LCD backlight will turn off in 30 seconds.

BUT

- If the batteries are STILL NOT replaced then the LCD will show again after 30 minutes:Critical low battery

Disc(s)…

REPLACE BATTERY- The main control box LCD backlight will enlighten for 30 seconds + sound a small “friendly” 3 beep (beep…beep…beep) every 30 minutes.- The RED LED on the main control box will flash continuously.(In this case go back to point 2a to solve the problem).

POSSIBILITY 2:Go to the valve and open manually, with the MANUAL OVER-RIDE function.This is done as following:- Go to the valve, and see on top of that valve 2 wheels: (one small wheel mentioning “LIFT UP AND TURN” and one big wheel)- Pull up the small wheel, and turn it into MANUAL position. (you will see that the 2 feet under that wheel will be lifted up, higher then normal).- Now you can OPEN and CLOSE the valve by turning the big wheels direction.- If the user has put the valve on manual position, the LCD screen will remain showing:

Critical low batteryDisc(s)…

REPLACE BATTERYAfter putting it back to AUTOMATIC mode AND AFTER REPLACING THE BATTERIES, the LCD screen will show immediately:

HYDRAVERT LOGOwater detecting system

- The main control box flashing RED LED will go back to GREEN.- The system is now back in normal functional mode.

3) POWER FAILURE/SHUT OFF/FALL OUT:

When the user is at home or he is not, and there is a power fall-out then the main control box will stop working.a) If the valve is on battery supply (ONLY): then the valve will close after maximum 25 minutes.In this case the home is entirely secured against water damages, for as long as the user has put the valve on electric AND battery supply as back-up.b) If the valve is on electric supply: only, then it will not react at all as all electric supply is off, and if the valve is open then it will remain open.If the valve was closed before, then it will remain closed.

What to do?- Apply electricity back to the home and the unit will restart itself, and/or apply electricity to the main control box. BUT the user MAY NOT PRESS ANY BUTTONS!!!

(IF NO TEXT IS SHOWING , THEN DISCONNECT THE ELECTRICITY ON THE MAIN CONTROL BOX AND RE-CONNECT IMMEDIATELY)

The LCD screen is firstly blank, and will then show:Push RESET

To Enter Teach ModeOR

WAIT forAutomatic Mode

IMPORTANT: DO NOT PUSH ANY BUTTONS AS THE SYSTEM WILL SET ITSELF BACK TO ITS ORIGINAL MEMORY AFTER 20 SECONDS.

Then after 20 seconds the LCD screen will show:SYSTEM INITIALIZING

Then LCD screen will show: WAITING FOR

…VALVE RESETTING…Then LCD screen will show:

...VALVE RESETTING…Then LCD screen will show:

VALVE OPEN–WATER OKAYSYSTEM STATUS OKAY

Then LCD screen will show:HYDRAVERT LOGO

Page 9: Water Filter S · Web viewHYDRAVERT® consists of 1 motorized central one-inch brass ball valve with manual override and 6 wireless R/F battery-operated discs and 1 central main control

water detecting system- The main control box flashing RED LED will go back to GREEN, and LCD backlight will turn off in 30 seconds.- Your system is now AGAIN fully operational and armed, and you are now AGAIN protected against water damages.

4) DISC MISSING, BROKEN, MALFUNCTIONING OR OUT OF REACH:

The discs will transmit its presence every 30 minutes, and if for one or the other reason the disc doesn’t transmit any longer then the main control box will alert the user.This can be multiple reasons as for example the disc was moved by accident from its “normal” location and/or is out of the coverage range, or it fell and broke.

IMPORTANT: If for example the LCD screen shows “MISSING/OUT OF RANGE”, and you found the disc on its original place, then it could be that the signal is too low for the disc to transmit, so in this case place the disc more viewable, or closer to the main control box.- If the main control box finds a missing communication from a disc after more then 2 attempts, then the LCD screen shows that 1 disc or more is missing: (In this example: disc n° 4)

The LCD will show:MISSING/OUT OF RANGE !

Disc(s): 4

Accept *Retry #

- The main control box LCD backlight will enlighten for 30 seconds + the RED LED on the main control box will flash continuously. (the buzzer will NOT sound).- To know where the disc(s) is situated, open the hinged door on the main control box and look on the back side of that hinged door to know where you placed that disc.

SOLUTIONS:a) RETRY:If you DO NOT ACCEPT that this disc will be cancelled from the program, and if you wish to RE-ENTER this disc into the program then do the following:PRESS RETRY #, and the LCD screen will show:

Insert BatteryInto Disc(s)

-Open the disc, and take out the existing (CR123A 3V Lithium) battery, and re-insert that same battery after 5 seconds, and a RED LED will flash inside the disc, confirming activation and reception. (the RED LED must flash)- Close the disc and place it back.The LCD screen will show OK next to that missing disc as following:

Disc 1: ok Disc 6: okDisc 2: ok Valve: okDisc 3: ok Disc 4: ok Accept *Disc 5: ok Retry #

- Then press Accept * and the LCD screen will show:…SAVING SETTINGS…

Then LCD screen will show:SETTINGS SAVED

Then LCD screen will show:HYDRAVERT LOGO

water detecting system- The main control box flashing RED LED will go back to GREEN, and LCD backlight will turn off in 30 seconds.- Your system is now AGAIN fully operational and armed, and you are now AGAIN protected against water damages.

b) ACCEPT:If you ACCEPT that this disc will be cancelled (eliminated) from the program, then do the following:- Remove the battery out of that disc and store it.- Press Accept * and the LCD screen will show:

…SAVING SETTINGS…Then LCD screen will show:

SETTINGS SAVEDThen LCD screen will show:

SYSTEM INITIALIZINGThen LCD screen will show:

VALVE OPEN–WATER OKAYSYSTEM STATUS OKAY

Then LCD screen will show:HYDRAVERT LOGO

water detecting system- The main control box flashing RED LED will go back to GREEN, and LCD backlight will turn off in 30 seconds.- Your system is now AGAIN fully operational and armed, and you are now AGAIN protected against water damages, but you cancelled (eliminated) a disc out of the program.

Page 10: Water Filter S · Web viewHYDRAVERT® consists of 1 motorized central one-inch brass ball valve with manual override and 6 wireless R/F battery-operated discs and 1 central main control

5) VALVE MANUAL OVERRIDE/MANUAL POSITION:

If you have no more electricity or no batteries or when the valve is stuck or malfunctioning:Go to the valve and open manually, with the “OVERRIDE” function.This is done as following:- Go to the valve, and see on top of that valve 2 wheels: (one small wheel mentioning “LIFT UP AND TURN” and one big wheel)- Pull up the small wheel, and turn it into “MANUAL” position. (you will see that the 2 feet under that wheel will be lifted up, higher then normal).- Now you can OPEN and CLOSE the valve by turning the big wheels direction.!!! Do not forget to put the small wheel back into “AUTOMATIC” position, after electricity is back or when you have applied batteries inside, and press “RESET” on the valve. (The valve will no matter where it is situated first close and immediately re-open).

6) SELF TEST:

The unit has a automatic function that will do a “self test” of the valve every day = (every 24 hours).This is to make sure the remains of lime, rust or any other dirt is taken away from the valve internal body.The valve will do a self test by closing the valve +- 50%, then stop and re-open immediately. (This process takes around 12 seconds).During this process, the LCD will stay enlighten continuously until the process is finished.Important: The unit will NOT do a self-test while in HOLIDAY ON mode, when there is a valve malfunction, a water alarm or when valve is closed.The LCD will show:

VALVE AUTOMATICSELF TEST

Then LCD screen will show (as long as the valve is in movement):VALVE

INMOVEMENT

Then LCD screen will show: VALVE AUTO SELF TEST

SUCCESFULSYSTEM STATUS OKAY

Then LCD screen will show:VALVE OPEN–WATER OKAY

SYSTEM STATUS OKAYThen LCD screen will show:

HYDRAVERT LOGOwater detecting system

Important: When the valve is on electricity and/or batteries, but the electricity is shut from the main control box, then the self test will NOT happen.

7) HOLIDAY:

a) Holiday ON:When the user is going away for a longer period then he most likely wants to close the main water supply.(If he doesn’t then still there is no problem as the whole system will guard his property as normal, as long as the main control box receives electricity).What to do?The user will need to push the button “HOLIDAY” for 4 seconds, and then the valve will automatically close. (the Red LED on the main control box will light-up continuously).The user will double check his water supply, and see that no water is running. (the valve will also not make any self test, until holiday mode is turned off).This function will remain in the memory of the main control box, even in the case of a electric fall-out.The LCD screen will show:

HOLIDAY ON SELECTEDThen LCD screen will show:

WAITING FOR…VALVE CLOSING…

Then LCD screen will show:…..VALVE CLOSING…..

Then LCD screen will show:HOLIDAY ON

VALVE CLOSED-NO WATERHoliday Off?Push RESET

The RED LED on the main control box will light-up continuously, and the LCD backlight will turn off in 30 seconds.

b) Holiday OFF:When the user comes back and wishes to turn off the “HOLIDAY”, then he will need to push on the “RESET” button.The LCD screen will show:

HOLIDAY ON

Page 11: Water Filter S · Web viewHYDRAVERT® consists of 1 motorized central one-inch brass ball valve with manual override and 6 wireless R/F battery-operated discs and 1 central main control

VALVE CLOSED-NO WATERHoliday Off?Push RESET

-When pushing RESET then the LCD screen will show:WAITING FOR

…VALVE OPENING…Then LCD screen will show:

…VALVE OPENING…Then LCD screen will show:

VALVE OPEN–WATER OKAYSYSTEM STATUS OKAY

Then LCD screen will show:HYDRAVERT LOGO

water detecting system- The RED LED on the main control box will go back to GREEN, and LCD backlight will turn off in 30 seconds.

8) “CLOSE” AND “OPEN” BUTTON:

a) CLOSE:When pushing the “CLOSE” button, and the valve is open, then the valve will automatically close.(If the valve is already closed, then this test will not be done, and the valve will remain closed).The LCD screen will show:

WAITING FOR…VALVE CLOSING…

Then LCD screen will show:….VALVE CLOSING...

Then LCD screen will show:VALVE CLOSED-NO WATER

Open Valve?Push OPEN Button

- The RED LED on the main control box will light-up continuously, and the LCD screen will stay enlighten for 30 seconds.

b) OPEN:When pushing the “OPEN” button and the valve is closed, then the valve will automatically open.(If the valve is already open, then this test will not be done, and the valve will remain open).If the valve is closed due to a water damage or battery issue or another issue, then the valve will remain closed!!!The LCD screen will show:

WAITING FOR…VALVE OPENING…

Then LCD screen will show:…VALVE OPENING…

Then LCD screen will show:VALVE OPEN–WATER OKAY

SYSTEM STATUS OKAYThen LCD screen will show:

HYDRAVERT LOGOwater detecting system

- The RED LED on the main control box will go back to GREEN, and LCD screen backlight will turn off in 30 seconds.

9) VALVE MALFUNCTION:

When the valve is stuck or jammed due to many factors like the remains of lime, rust or any other dirt is pilling up in and round the valve internal body, or even a sudden electric fall-out, then the system will alert the user showing the LCD screen light-up for 30 seconds and the RED LED on the main control box will flash continuously + sound a 3 beep (beep…beep…beep) every 30 seconds.The RED and GREEN LED on the valve will light-up continuously, to indicate a valve malfunction.This means that the motor has to use too much power to close or open the valve, to protect the motor or inside parts such as gears and wheels!The LCD screen will show:

VALVE MALFUNCTION

CHECK VALVE ORCALL PLUMBER

PUSH RESET BUTTON

a) SOLUTION 1: If you press RESET, then the valve will move, and the LCD screen will show:

WAITING FOR…VALVE RESETTING…

Then LCD screen will show: ...VALVE RESETTING…

Then LCD screen will show:VALVE OPEN–WATER OKAY

SYSTEM STATUS OKAYThen LCD screen will show:

HYDRAVERT LOGOwater detecting system

Page 12: Water Filter S · Web viewHYDRAVERT® consists of 1 motorized central one-inch brass ball valve with manual override and 6 wireless R/F battery-operated discs and 1 central main control

In this case the system is back to normal.

b) SOLUTION 2:- Go to the valve, and see on top of the valve 2 wheels: (one small wheel mentioning “LIFT UP AND TURN” and one big wheel)- Pull up the small wheel, and turn it into MANUAL position. (you will see that the 2 pins under that wheel will be lifted up, higher then normal = sitting in 2 dimpling holes).- Now you can OPEN and CLOSE the valve by turning the big wheel direction.- Turn this big wheel back and forth multiple times, so that it becomes “smoother”, as the more you turn, the more the dirt inside the valve is clearing and disappearing.- Then put back the small wheel into AUTOMATIC position. (you will see that the 2 pins under that wheel will be lowered into 2 full holes).- Now the valve is back in AUTOMATIC position, and now you can no longer turn the big wheel as it is in motor engaged position.-Now press the RESET button on the valve, and the valve will automatically close and immediately re-open (the RED LED will flash, and then the GREEN LED will flash, until the valve stops and shows a continuous GREEN LED.- Go back to the main control box, where you will press the RESET button.- If then the problem is NOT solved, either repeat this action again, or call a plumber. C) IMPORTANT POINTS OF USE:

1) MAINTENANCE:

- It is recommended to follow the next proceedings every 6 months:Go to the valve, and see on top of the valve 2 wheels: (one small wheel mentioning “LIFT UP AND TURN” and one big wheel)- Pull up the small wheel, and turn it into MANUAL position. (you will see that the 2 pins under that wheel will be lifted up, higher then normal = sitting in 2 dimpling holes).- Now you can OPEN and CLOSE the valve by turning the big wheel direction.- Turn this big wheel back and forth multiple times, so that it becomes “smoother”, as the more you turn, the more the dirt inside the valve is clearing and disappearing.- Then put back the small wheel into AUTOMATIC position. (you will see that the 2 pins under that wheel will be lowered into 2 full holes).- Now the valve is back in AUTOMATIC position, and now you can no longer turn the big wheel as it is in motor engaged position.-Now press the RESET button on the valve, and the valve will automatically close and immediately re-open (the RED LED will flash, and then the GREEN LED will flash, until the valve stops and shows a continuous GREEN LED.

2) IMPORTANT NOTICE:

Info 1:- When pushing RESET on the valve, then the valve will reset itself and close, and then immediately re-open even when the valve is open.It will first close the valve even when the valve is 95% closed, and then open 100%.- if the valve is not moving either check the batteries or electric supply or press the “RESET” button on top of the valve.- Some promotional units come with batteries included (check your unit/battery every year).- The complete unit does not have an on/off switch (when applying either electricity and/or batteries, it is armed and operating)- The overall duration of the battery will depend on the strength of the battery to begin with.- If the unit is sounding and there is no apparent water present, check carefully for small leaks in the area first, wipe the disc dry and follow the instructions above. If the alarm still sounds when placed into position and there is no moisture present, it is possible that the floor is electrically conductive. In this case, try placing the disc on a small section of paper towel. If the alarm still sounds, the unit may be malfunctioning.- Place the discs at the lowest point of flooring underneath or beside the areas of potential leaks. The lowest point can be found by placing a marble or round object on the floor to see which way it rolls. An alternative is to use a level. In areas where the floor is not sloped enough to detect, place the discs where water is most likely to be sourced from: such as underneath valves, fittings, or the lowest point of tubing. - The valve is placed on the central main water entry, and the main control box is to be installed either in the kitchen or garage, but preferably centralised AND ONLY on the ground floor in the home.Important: (for apartments it is recommended to connect the valve to the main water entry coming into the apartment on the same floor).The system could not be applicable in case of passing several floors between the valve and main control box. (the connection between these two components needs to be excellent).

Caution!- ONLY OPEN the discs to reset after a water damage, or for a battery replacement.- The metal leads on the back or on the bottom of the discs must be facing downwards for the alarm to work.- Prolonged exposure to loud sounds may damage hearing.- Do not place the unit in water or wipe with a wet sponge or towel to clean. Clean the unit only with a dry cloth.- Any tampering with or repairing the unit voids the warranty. (the unit is equipped with a special label to avoid tampering)- Alarms are not foolproof. Like any other electronic device, they are made of components that can wear or fail at any time. Their performance is especially subject to impact, dust, flooding and lack of proper maintenance. They cannot work without power. If the battery is not correctly installed, is missing, or depleted, the alarm will be inoperative.- The unit will not work without electricity and/or batteries installed. The electricity and/or battery must be installed immediately, or the unit will fail. Read and follow instructions or unit will not operate properly.- Although the unit is designed to be loud enough to be heard in nearby rooms, it may not be heard.- The unit will not sound if the water leak does not reach the disc. Leaks that occur in adjacent or nearby areas where water does not travel in the path of the disc will not trigger the alarm.- Although the unit is water resistant, it is not waterproof and flooding can damage the electronics and inhibit the function of the unit.- The unit has a limited life. The unit should be replaced immediately if it is not operating properly. - Never drop the unit.- Although the unit is made to detect water leakage, it is an electronic device susceptible to damage and malfunction.- The unit is solely meant to be a helpful device with no guarantees expressed or implied.- Check with your insurance company for possible premium discounts when using this system.

Page 13: Water Filter S · Web viewHYDRAVERT® consists of 1 motorized central one-inch brass ball valve with manual override and 6 wireless R/F battery-operated discs and 1 central main control

Info 2:- It is recommended that you apply ONLY electricity to the valve.- BACKLIGHT: If you wish to light-up the LCD screen then press “TOUCH BACKLIGHT” on the main control box. (between the RED and GREEN LED)- This product does not guarantee the prevention of water damage.Many factors increase the probability of preventing water damage including :Constant HYDRAVERT® testing / Physical verification of all parts / Correct placement of the discs

For questions or problems, call your plumber, or contact our support help line: [email protected]