Zapata Aislada15x80

9
1 0.32 1/4 " 2 0.71 3/8 " 3 1.27 1/2 " 4 1.98 5/8 " 5 2.85 3/4 " 6 5.1 1 " 1 0.32 1/4 " 2 0.71 3/8 " 3 1.27 1/2 " 4 1.98 5/8 " 5 2.85 3/4 " 6 5.1 1 "

description

asdfasdfasf ashagasdfas fasf asgsagjsdfgasfas fsadfasfas fsaf asfaghasdfas f

Transcript of Zapata Aislada15x80

Hoja1

10.321/4 "20.713/8 "31.271/2 "41.985/8 "52.853/4 "65.11 "

10.321/4 "20.713/8 "31.271/2 "41.985/8 "52.853/4 "65.11 "

Diseo de zapata AisladaDISEO DE ZAPATA AISLADA

DATOS GENERALES:SECCION DE COLUMNAt1 =0.15mts.t2 =0.50mts.CARGA MUERTA:PD =4.00Tn.CARGA VIVA:PL =1.00Tn.CAPACIDAD PORTANTE DEL SUELO:t =2.50kg/cm2.PROFUNDIDAD DE DESPLANTE:Df =2.60mts.PESO ESPECIFICO DEL TERRENO:t =2.10Tn/m3.RESISTENCIA DEL CONCRETO DE LA ZAPATA:f'c =280.00kg/cm2.SOBRECARGA DEL PISO:s/c =500.00kg/m2.RESISTENCIA DEL ACERO:Fy =4200.00kg/cm2.RECUBRIMIENTOR =7.50cmtDIAMETRO DE LAS VARILLAS DE REFUERZO:v =1.27cm.

ALTURA A NIVEL DE PISO TERMINADOh f =2.90mts.ESFUERZO NETO DEL TERRENO " n ":n =18.41Tn/m20.2715915263AREA DE LA ZAPATA " Azap ":Azap = 0.27m2S' x T' =0.530x0.530m2

PARA CUMPLIR Lv1 = Lv2

T =0.705mts. UtilizarT =1.200mt

S =0.355mts. UtilizarS =0.700mt

USARS x T0.700x1.200

Lv1 = Lv2 =0.2500.250

REACCION NETA DEL TERRENO " Wnu ":Pu =7.3TnAz =0.84m2

Wnu = 8.69Tn/m2

DIMENSIONAMIENTO DE LA ALTURA " h " DE LA ZAPATA POR PUNZONAMIENTO:CONDICION DE DISEO:

Vc = Vu/ = (Pu-Wu.m.n)/. ( I )

TAMBIEN: = 0.85Vc = 1.06(f'c)xboxd .( II )I = IIFormando una ecuacion de segundo Gradoa =611.7550233162b =201.64c =-6.65Entonces d =0.0302mt

h =11.79cm usarh =60.000cm

dprom =0.510m

VERIFICACION DE CORTANTE:

Lv =0.300mts.Vdu =-1.28Tn.Vn =-1.50Tn.

Vc =31.66Tn > VnCONFORME

SENTIDO LONGITUDINAL:

DISEO POR FLEXION:Mu =0.19Tn-md =51.00cm2.F'c=280.00kg/cm2Fy =4200.00kg/cm2b =70.00cmITERANDO:d = FACTOR DE REDUCCION DE DISEO IGUAL A 0.9d =0.90Asumiendo a =10.2cm

As =0.11cm2a =0.028cm As =0.10cm2a =0.025cm As =0.10cm2a =0.025 As =0.10cm2

Usar As = 0.10cm2a =0.025

VERIFICACION DE ACERO MINIMO:Asmin = (temp).(b).(d)Asmin = 6.43cm2. Ldisp =22.500cm verificar diametro de barraTransferencia de fuerza en la interfase de columna y cimentacion

a.- Transferencia al Aplastamiento sobre la columna

F'c =280.00Kg/cm2Pu =7.3Tn

Pn =11.23TnResistencia al Aplastamiento de la columna PnbPnb =178.5Tn

Pn < Pnb conforme

b.- Resistencia al Aplastamiento en el concreto de la CimentacionPn =11.23

Xo =0.36mtA2 =0.432mtA1 =0.075mt(A2/A1)^0,5 =2.4usar2.00

Ao =0.15

Pnb =357TnPn < Pnb conforme Dowells entre columna y cimentacionsi Pn < Pnbusar Asmin =3.75cm2para zonas sismicas