7/16/2019 67653582 Ventilacion de La Mina Raura
1/36
UNIVERSIDAD NACIONAL DE PIURA
FACULTAD DE INGENIERIA DE MINAS
TEMA : VENTILACION DE
LA MINA RAURA
INTEGRANTES : Zambrano Hurtado Gloria
Ramos Garca Jose LuisLpez Ramrez Juan Carlos
Merino Carhuachinchay Jhermain
Ojeda Carrin Keber
PROFESOR : ING. JOSE CHANG VALDIVIEZO.
7/16/2019 67653582 Ventilacion de La Mina Raura
2/36
MINA RAURA: UBICACION
7/16/2019 67653582 Ventilacion de La Mina Raura
3/36
UBICACIN Y ACCESO
UBICACION:
Distrito: San Miguel de Cauri
Provincia: Lauricocha
Dpto: HunucoALTITUD: 4,700 m.s.n.m.
ACCESO:
1- Huacho-Sayn-Oyn-Raura
2- Hunuco-Jess-Cauri-Raura
3- Pasco-Oyn-Raura
Lima La Oroya
Cerro de PascoRaura Oyn
7/16/2019 67653582 Ventilacion de La Mina Raura
4/36
CA. MINERA RAURA S.A. RECIBI EN DICIEMBRE
DEL 2005 LA CERTIFICACIN INTERNACIONAL EN ISO-14001 (AUDITORA INTERNACIONAL BUREAU VERITAS)
LA AUDITORIA INTERNACIONAL DE OHSAS SEREALIZARA EN EL MES DE OCTUBRE DEL 2006
SE ASEGURA QUE NUESTROS PROCESOS YNUESTRAS OPERACIONES CUMPLEN CON LOSESTNDARES INTERNACIONALES DE SEGURIDAD YCALIDAD AMBIENTAL
7/16/2019 67653582 Ventilacion de La Mina Raura
5/36
7/16/2019 67653582 Ventilacion de La Mina Raura
6/36
7/16/2019 67653582 Ventilacion de La Mina Raura
7/36
INTRODUCCION- LA UNIDAD MINERA RAURA, DE PROPIEDAD DE LA CA.MINERA RAURA S.A. INICI SUS OPERACIONES EN 1960.ESTAS OPERACIONES SE EJECUTARON MEDIANTE LABORESSUBTERRNEAS CON PRODUCCIN DE MINERALPOLIMETLICO
- ACTUALMENTE, CA. MINERA RAURA S.A., ES UNAEMPRESA PERUANA DE LA MEDIANA MINERA, DEDICADA ALAS ACTIVIDADES MINERO METALRGICAS DE EXPLOTACIN,BENEFICIO Y COMERCIALIZACIN DE CONCENTRADOS DE
MINERALES POLIMETLICOS (ZINC, PLATA, COBRE Y PLOMO).
7/16/2019 67653582 Ventilacion de La Mina Raura
8/36
- LOS MTODOS DE EXPLOTACIN SON: SHIRINKAGE,CORTE Y RELLENO ASCENDENTE (BREASTING Y TALADROSINCLINADOS), CMARAS Y PILARES, BLOCK CAVING (TALADROSLARGOS).
- COMPAA MINERA RAURA S.A. BUSCA DESARROLLAR UNSISTEMA DE VENTILACIN PTIMO QUE BRINDE UN AMBIENTESEGURO , SALUDABLE Y CMODO AL PERSONAL EN INTERIORMINA
- COMPAA MINERA RAURA S.A. BUSCA LOGRAR AHORROS
EN SUS COSTOS DE OPERACIN REFERENTE A VENTILACIN
- EN UNA MINA COMO RAURA NO SE PUEDE LOGRARBUENOS RESULTADOS EN VENTILACIN SINO SE CUENTA CONLOS EQUIPOS Y LA INFRAESTRUCTURA ADECUADOS, ELDIRECCIONAMIENTO Y VOLUMEN DE AIRE REQUERIDO SE DEBELOGRAR CON AYUDA DE VENTILACIN MECNICA
7/16/2019 67653582 Ventilacion de La Mina Raura
9/36
PLANO ISOMETICO - RAURA
7/16/2019 67653582 Ventilacion de La Mina Raura
10/36
CIRCUITO DE VENTILACION PRIMARIO
INGRESO DE AIRE A CATUVA
Nv 300 (SHUCSHAPAJ) INGRESA AIRE
Nv 380 (TINQUICOCHA) INGRESA AIRE
Nv 590 (HIDRO) INGRESA AIRENv 630 (CATUVA) INGRESA AIRE
Nv 700 (CATUVA) INGRESA AIRE
7/16/2019 67653582 Ventilacion de La Mina Raura
11/36
CIRCUITO PRIMARIO CATUVA
7/16/2019 67653582 Ventilacion de La Mina Raura
12/36
CIRCUITO DE VENTILACION PRIMARIOSALIDA DE AIRE CATUVANv 630, RB 66
Nv 630, RB 69
Nv 630, RB 70Nv 630, RB 02
Nv 630, RB 23
Nv 630, RB 10
Nv 700, RB 09
7/16/2019 67653582 Ventilacion de La Mina Raura
13/36
BALANCE DE AIRE PARA MINA CATUVANECESIDADES DE AIRE PARA CATUVA
POR LA CANTIDAD DE HOMBRES POR GUARDIA148 hombres x 6.0 m3/min 888.00 m3/minPOR EL USO DE EQUIPO DIESEL
1681.50 HP x 3.0 m3/HP/min 5,044.50 m3/minPOR EL USO DE EXPLOSIVOS25.0 m/min x 8 Nv x 11.11 m2 2,222.00 m3/min
TOTAL 8,154.50 m3/min
287,972.90 CFM
7/16/2019 67653582 Ventilacion de La Mina Raura
14/36
BALANCE DE AIRE PARA MINA CATUVAINGRESO DE AIRE ( ANTES )
LUGAR DE INGRESO m3/min CFM
Nv 300, Cx 575 1,534.91 54,204.73
Nv 380, Cr 080 SW 594.45 20,992.78
Nv 380 199.32 7,038.91
Nv 590, Cr 070 SW 528.96 18,680.01
Nv 590 RB 140.99 4,979.00
Nv 590, Gl 480 86.14 3,041.99
Nv 630, Cx 230 SW 2,062.54 72,837.77
Nv 700 114.94 4,059.06
TOTAL 5,262.25 185,834.25
7/16/2019 67653582 Ventilacion de La Mina Raura
15/36
BALANCE DE AIRE PARA MINA CATUVAINGRESO DE AIRE ( DESPUES )
LUGAR DE INGRESO m3/min CFM
Nv 300, Cx 575 2,944.75 104,000.50
Nv 380, Cr 080 SW 594.45 20,992.78
Nv 380 199.32 7,038.91
Nv 590, Cr 070 SW 1,529.11 54,000.00
Nv 590 RB 140.99 4,979.00
Nv 590, Gl 480 86.14 3,041.99
Nv 630, Cx 230 SW 3123.35 110,300.00
Nv 700 114.94 4,059.06
TOTAL 8,733.27 308,412.24
7/16/2019 67653582 Ventilacion de La Mina Raura
16/36
RESUMEN BALANCE DE AIRE CIRCUITO PRINCIPAL
CATUVA
INGRESO
DE AIRE
CFM
NECESIDAD
DE AIRE
CFM
COBERTURA
%
OBSERVACION
185,834.25 287,972.90 64.50
ANTES DEINSTALAR
VENTILADORES
308,412.24 287,972.90 107.10
DESPUES DE LAINSTALACION DEVENTILADORES
7/16/2019 67653582 Ventilacion de La Mina Raura
17/36
- LAS CORRECCIONES HECHAS AL CIRCUITO PRINCIPAL:INCREMENTO DE CAUDAL DE AIRE DE 185,834.25 CFM A
308,412.24 CFM
- SE LOGRO INSTALANDO 02 VENTILADORES DE 100,000 CFM Y01 VENTILADOR DE 50,000 CFM, AS COMO ELMEJORAMIENTO DE PUERTAS Y TAPONES DE VENTILACION
- - CON ESTA CORRECCION EL SISTEMA DE VENTILACION
CUMPLE CON LA NECESIDAD DE AIRE REQUERIDO EN MINACATUVA
7/16/2019 67653582 Ventilacion de La Mina Raura
18/36
PUERTA DE VENTILACION
7/16/2019 67653582 Ventilacion de La Mina Raura
19/36
VENTILACION SECUNDARIA
7/16/2019 67653582 Ventilacion de La Mina Raura
20/36
- PARA LOS CIRCUITOS SECUNDARIOS, LUEGO DE LAEVALUACION SE DETERMINO COMPLETAR LASPREPARACIONES EN LAS LABORES DE EXPLOTACION
- LA CONSTRUCCION DE DUCTOS METALICOS PARA ELIMINARCAIDAS DE PRESION EN LOS CODOS
- EL USO DE MANGAS DE VENTILACION CON LOS DIAMETROSAPROPIADOS
- PARA LABORES MAYORES A 60.0 m DE LONGITUD SEINSTALAN VENTILADORES EN SERIE GENERALMENTE CADA
100.0 m (DEPENDIENDO DE LA CAPACIDAD DEL VENTILADOR)
7/16/2019 67653582 Ventilacion de La Mina Raura
21/36
VENTILADOR SECUNDARIO
7/16/2019 67653582 Ventilacion de La Mina Raura
22/36
DISTRIBUCION Y COSTO DE VENTILACION ANTERIOR
VENTILADOR MOTOR FACTOR CAPACIDAD Kw-h $/Kw-hora $/dia $/ao UBICACIN
(Kw) (horas) (CFM)
VMR-12 75.00 1.0 50,000 1800.00 0.045 81.00 29160.00 Nv 300
VMR-13 11.25 1.0 8,000 270.00 0.045 12.15 4374.00 Nv 300, Tj 835
VMR-14 95.25 0.8 50,000 1714.50 0.045 77.15 27774.90 Nv 300,Cx 035
VMR-11 22.50 1.0 20,000 540.00 0.045 24.30 8748.00 Nv 340, Rp 895
VMR-10 24.00 1.0 20,000 576.00 0.045 25.92 9331.20 Nv 380, Cx 100
VMR-09 11.25 1.0 15,000 270.00 0.045 12.15 4374.00 Nv 380, Cx 315VMR-05 37.50 0.8 18,000 675.00 0.045 30.38 10935.00 Nv 490, Cx 943
VMR-06 15.00 0.8 15,000 270.00 0.045 12.15 4374.00 Nv 490, Cx 943
VMR-08 15.00 1.0 15,000 360.00 0.045 16.20 5832.00 Nv 490
VMR-03 41.25 0.8 20,000 742.50 0.045 33.41 12028.50 Nv 590, Cx 112
VMR-04 34.50 0.8 20,000 621.00 0.045 27.95 10060.20 Nv 540, Tj 082
VMR-01 191.25 1.0 120,000 4590.00 0.045 206.5 74358.00 Nv 630
VMR-02 150.00 1.0 100,000 3600.00 0.045 162.0 58320.00 Nv 630
VMR-15 24.00 0.8 15,000 432.00 0.045 19.44 6998.40 Nv 630, Tj 990
VMR-16 24.00 0.8 20,000 432.00 0.045 19.44 6998.40 Nv 740, Tj 130
VMR-27 40.73 1.0 20,000 977.40 0.045 43.98 15833.88 Nv 440, COBRI
TOTAL 812.48 17870.4 804.1 255966.4
7/16/2019 67653582 Ventilacion de La Mina Raura
23/36
DISTRIBUCION Y COSTO DE VENTILACION ACTUAL
VENTILADOR MOTOR FACTOR CAPACIDAD Kw-h $/Kw-hora $/dia $/ao UBICACIN
(Kw) (horas) (CFM)
VMR-12 75.00 1.0 50,000 1800.00 0.045 81.00 29160.00 Nv 300
VMR-13 11.25 1.0 8,000 270.00 0.045 12.15 4374.00 Nv 300, Tj 835
VMR-09 11.25 1.0 15,000 270.00 0.045 12.15 4374.00 Nv 380, Cx 315
VMR-06 15.00 0.8 15,000 270.00 0.045 12.15 4374.00 Nv 490, Cx 943
VMR-08 15.00 1.0 15,000 360.00 0.045 16.20 5832.00 Nv 490
VMR-03 41.25 0.8 20,000 742.50 0.045 33.41 12028.50 Nv 590, Cx 112
VMR-01 191.25 1.0 120,000 4590.00 0.045 206.55 74358.00 Nv 630
VMR-02 150.00 1.0 100,000 3600.00 0.045 162.00 58320.00 Nv 630
VMR-15 24.00 0.8 15,000 432.00 0.045 19.44 6998.40 Nv 630, Tj 990
TOTAL 534.00 12334.50 555.05 166284.90
7/16/2019 67653582 Ventilacion de La Mina Raura
24/36
VENTAJAS LOGRADAS
- SE REDUJO EL NUMERO DE VENTILADORES INSTALADOS DE16 A 09, CON EL CONSIGUIENTE AHORRO DE ENERGIA
- SE DA MAS EFICIENCIA A LAS OPERACIONES DEBIDO A QUE
LOS TIEMPOS PARA VENTILACION SON MENORES
- DEBIDO A QUE SE CONSTRUYERON CHIMENEAS DEVENTILACION EN LAS LABORES SE HACE POSIBLE EL USODE ANFO
- EL AHORRO EN VENTILACION CALCULADO SOLO PARACATUVA ES: 89,681.58 US$/AO
7/16/2019 67653582 Ventilacion de La Mina Raura
25/36
VENTILACION SECUNDARIA
RB-83 Y RB 79 NV 540 A 300 B BALILLA
NV-540
NV-300
NV-380
NV-490
RB-83 RB-79
7/16/2019 67653582 Ventilacion de La Mina Raura
26/36
PLANTA RB-83 NV 540 A 300 B. BALILLA
NV-540
NV-300
NV-380
NV-490RB-83
7/16/2019 67653582 Ventilacion de La Mina Raura
27/36
SECCION RB-83 NV 540 A 300 B BALILLA
NV-540
NV-300
NV-380
NV-490
RB-83
INCLINACION =-79
LONGITUD =238.00 MTS CUERPO DE MINERAL
SUBNIVEL
7/16/2019 67653582 Ventilacion de La Mina Raura
28/36
VENTILACION SECUNDARIA
7/16/2019 67653582 Ventilacion de La Mina Raura
29/36
VENTILACION SECUNDARIA
7/16/2019 67653582 Ventilacion de La Mina Raura
30/36
CALIDAD DEL AIRE
- UN BUEN SISTEMA DE VENTILACIN REQUIERE TAMBIN EL
MONITOREO CONSTANTE DE VEHCULOS QUE INGRESAN AINTERIOR MINA, QUE LA EMISION DE GASES DE ESTOSVEHICULOS ESTE CONTROLADA
- LA CANTIDAD DE AIRE NO DEBE SER MENOR A 3.0 m3/min
POR CADA HP QUE DESARROLLEN LOS EQUIPOS
- LA CALIDAD DEL AIRE ESTA EN FUNCIN AL CONTENIDO DEO2 (MAYOR A 19.5% VOLUMEN)
- PARA EL USO DE ANFO LA VELOCIDAD NO DEBER SERMENOR A 25 m3/min
- LA EVALUACIN DEL CIRCUITO DE VENTILACIN SEREALIZARA EN UN PERIODO MENOR A 06 MESES
7/16/2019 67653582 Ventilacion de La Mina Raura
31/36
CALIDAD DEL AIRE
MONITOREO
SEMANAL DE CO
7/16/2019 67653582 Ventilacion de La Mina Raura
32/36
CONCLUSIONES:- EL NUMERO DE PERSONAL EN CATUVA ES:
EE OPEMISS SRL : 65 hombres
EE MICONG SRL : 55 hombresAESA MINING : 13 hombresOTROS : 15 hombresHACEN UN TOTAL DE 148 hombres, REQUIRIENDO UN TOTAL DE888.00 m3/min DE AIRE
- EN MINA CATUVA SE TIENEN EN OPERACIN EN INTERIOR MINA ENSIMULTANEO DURANTE EL TURNO:SCOOPTRAMS : 06 undC BAJO PERFIL: 02 undCAMIONETAS : 13 undCAMIONES : 06 und
VOLQUETES : 08 undEQ SERVICIOS : 02 undHACIENDO UN TOTAL DE 1681.50 HP Y REQUIRIENDO UN CAUDAL DE5,044.50 m3/min DE AIRE
7/16/2019 67653582 Ventilacion de La Mina Raura
33/36
- EL PROBLE MA DE LA VENTILACION SE AGUDIZA DEBIDO A QUE LASLABORES SE POLARIZAN
- EL CIRCUITO PRIMARIO DE VENTILACION EN CATUVA ESTADISEADO PARA SUMINISTRAR AIRE A CADA LABOR DE LA MINA,PARA ELLO ES NECESARIO ORGANIZAR LA VENTILACIONSECUNDARIA
- LAS LABORES DEBEN CUMPLIR SUS ETAPAS HASTA QUEDARAPTAS PARA SU EXPLOTACION, UNA BUENA PLANIFICACION DELABORES AYUDARA A EVITAR FUTUROS PROBLEMAS DEVENTILACION
- LAS CHIMENEAS DE VENTILACION QUE SON PARTE DEL CIRCUITO
PRINCIPAL DE VENTILACION TAMBIEN PUEDEN SER USADAS COMOCHIMENEAS DE SERVICIOS PARA LINEA ELECTRICA, TUBERIA DERH. AGUA, AIRE COMPRIMIDO, ETC, Y DEBEN SER INDEPENDIENTESDE LAS LABORES QUE VENTILAN LOS TAJEOS
7/16/2019 67653582 Ventilacion de La Mina Raura
34/36
- EL CIRCUITO PRINCIPAL DE VENTILACION EN CATUVA SE
ALIMENTA DE AIRE LIMPIO POR 05 NIVELES DE LA MINA ELCUAL SE CONDUCE A LAS LABORES EN OPERACIN
- 02 NIVELES ALIMENTAN AIRE EN DESCENSO Y 03 NIVELESALIMENTAN AIRE ASCENDENTE
- TODO ESTE AIRE SE HACE LLEGAR AL Nv 540 DE LA MINA QUE
SE CONVIERTE EN EL CENTRO DEL SISTEMA DE VENTILACIONY DESDE ALLI SE EXTRAE CON 02 VENTILADORES DE 100,000CFM A TRAVES DE RBs A SUPERFICIE
- SE DEBE MANEJAR EL CONCEPTO DE INSTALAR
VENTILADORES SECUNDARIOS SOLO EN LABORES DE AVANCE
7/16/2019 67653582 Ventilacion de La Mina Raura
35/36
BIBLIOGRAFIAwww.todoexpertos.comwww.arqhys.com/ventilacion-minas.
www.derenatura.com/elrinconminero
www.raura.com
7/16/2019 67653582 Ventilacion de La Mina Raura
36/36
Top Related