8/18/2019 Astm d5873 Esclerometro
1/4
Designation: D5873 − 05
Standard Test Method for
Determination of Rock Hardness by Rebound HammerMethod1
This standard is issued under the fixed designation D5873; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope*
1.1 This test method covers the testing apparatus, sampling,
test specimen preparation, and testing procedures for determin-
ing the rebound hardness number of rock material using a
spring-driven steel hammer, referred to variously as a rebound
hammer, impact test hammer, or concrete test hammer.
1.2 This test method is best suited for rock material withuniaxial compressive strengths (see Test Method D7012)
ranging between approximately 1 and 100 MPa.
1.3 The portable testing apparatus may be used in the
laboratory or field to provide a means of rapid assessment of
rock hardness or to serve as an indicator of rock hardness.
1.4 The values stated in SI units are to be regarded as the
standard.
1.5 This standard does not purport to address all of the
safety concerns, if any, associated with its use. It is the
responsibility of the user of this standard to establish appro-
priate safety and health practices and determine the applica-
bility of regulatory limitations prior to use.
2. Referenced Documents
2.1 ASTM Standards:2
C805 Test Method for Rebound Number of Hardened Con-
crete
D420 Guide to Site Characterization for Engineering Design
and Construction Purposes
D653 Terminology Relating to Soil, Rock, and Contained
Fluids
D3740 Practice for Minimum Requirements for Agencies
Engaged in Testing and/or Inspection of Soil and Rock as
Used in Engineering Design and Construction
D4543 Practices for Preparing Rock Core as Cylindrical Test
Specimens and Verifying Conformance to Dimensional
and Shape Tolerances
D4879 Guide for Geotechnical Mapping of Large Under-
ground Openings in Rock
D7012 Test Method for Compressive Strength and Elastic
Moduli of Intact Rock Core Specimens under Varying
States of Stress and Temperatures
2.2 ISRM Standards:Suggested Method for Determination of Schmidt Rebound
Hardness3
Suggested Method for Quantitative Description of Discon-
tinuities in Rock Masses3
3. Terminology
3.1 For common definitions of terms in this standard, refer
to Terminology D653.
3.2 Definitions of Terms Specific to This Standard:
3.2.1 rebound hammer— a portable, spring loaded, piston-
type, steel hammer used to classify the hardness of rock in the
field or laboratory.3.2.2 rebound hardness number— HR, a dimensionless num-
ber representing empirically determined, relative hardness of
rock material or other hard substance by use of a rebound
hammer.
4. Significance and Use
4.1 The rebound hardness method provides a means for
rapid classification of the hardness of rock during site charac-
terization for engineering, design, and construction purposes
(see Guide D420), geotechnical mapping of large underground
openings in rock (see Guide D4879), or reporting the physical
description of rock core (see Practice D4543). The rebound
hardness number, H r , can serve in a variety of engineering
applications that require characterization of rock material.
These applications include, for examples, the prediction of
penetration rates for tunnel boring machines, determination of
rock quality for construction purposes, and prediction of
hydraulic erodibility of rock.
1 This test method is under the jurisdiction of ASTM Committee D18 on Soil and
Rock and is the direct responsibility of Subcommittee D18.12 on Rock Mechanics.
Current edition approved Nov. 1, 2005. Published November 2005. Originally
approved in 1995. Last previous edition approved in 2005 as D5873 – 00(2005)e1.
DOI: 10.1520/D5873-05.2 For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at [email protected]. For Annual Book of ASTM
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website.
3 Brown, E. T., ed., Suggested Methods: Rock Characterization, Testing, and
Monitoring, International Society of Rock Mechanics: Pergamon Press, London,
1981.
*A Summary of Changes section appears at the end of this standardCopyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1Copyright by ASTM Int'l (all rights reserved);
http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://dx.doi.org/10.1520/C0805http://dx.doi.org/10.1520/C0805http://dx.doi.org/10.1520/D0420http://dx.doi.org/10.1520/D0420http://dx.doi.org/10.1520/D0653http://dx.doi.org/10.1520/D0653http://0.0.0.0/http://dx.doi.org/10.1520/D3740http://dx.doi.org/10.1520/D3740http://dx.doi.org/10.1520/D3740http://dx.doi.org/10.1520/D4543http://dx.doi.org/10.1520/D4543http://dx.doi.org/10.1520/D4543http://dx.doi.org/10.1520/D4879http://dx.doi.org/10.1520/D4879http://dx.doi.org/10.1520/D7012http://dx.doi.org/10.1520/D7012http://dx.doi.org/10.1520/D7012http://0.0.0.0/http://0.0.0.0/http://www.astm.org/COMMIT/COMMITTEE/D18.htmhttp://www.astm.org/COMMIT/SUBCOMMIT/D1812.htmhttp://www.astm.org/COMMIT/SUBCOMMIT/D1812.htmhttp://www.astm.org/COMMIT/COMMITTEE/D18.htmhttp://0.0.0.0/http://0.0.0.0/http://dx.doi.org/10.1520/D7012http://dx.doi.org/10.1520/D7012http://dx.doi.org/10.1520/D7012http://dx.doi.org/10.1520/D4879http://dx.doi.org/10.1520/D4879http://dx.doi.org/10.1520/D4543http://dx.doi.org/10.1520/D4543http://dx.doi.org/10.1520/D4543http://dx.doi.org/10.1520/D3740http://dx.doi.org/10.1520/D3740http://dx.doi.org/10.1520/D3740http://0.0.0.0/http://dx.doi.org/10.1520/D0653http://dx.doi.org/10.1520/D0653http://dx.doi.org/10.1520/D0420http://dx.doi.org/10.1520/D0420http://dx.doi.org/10.1520/C0805http://dx.doi.org/10.1520/C0805http://0.0.0.0/http://0.0.0.0/
8/18/2019 Astm d5873 Esclerometro
2/4
4.2 This test method is of limited use on very soft rock or
very hard rock (unconfined compressive strengths less than
approximately 1 MPa or greater than 100 MPa).
4.3 The results of this test method are not intended for
conversion to strength data suitable for design.
NOTE 1—Several types of rebound hammers are commercially availableto accommodate testing of various sizes and types of concrete construction(See Test Method C805) and rock material.
NOTE 2—The quality of the result produced by this standard isdependent on the competence of the personnel performing it, and thesuitability of the equipment and facilities used. Agencies that meet thecriteria of Practice D3740 are generally considered capable of competentand objective testing and sampling. Users of this standard are cautionedthat compliance with Practice D3740 does not in itself assure reliableresults. Reliable results depend on many factors; Practice D3740 providesa means of evaluating some of those factors.
5. Apparatus
5.1 Rebound Hammer, consisting of a spring-loaded piston,
or hammer, which is projected against a metal anvil in contact
with the rock surface. The hammer must travel with a fixed andreproducible velocity. The rebound distance of the piston from
the steel plunger is measured in a linear scale attached to the
frame of the instrument and is taken as an empirical measure of
rock hardness.
5.2 Steel Base— A steel base of minimum mass of 20 kg to
which specimens are securely fastened. Rock core specimens
may be tested in a steel cradle with a semicylindrical machined
slot of the same radius as the core, or firmly seated in a steel
V-block, see Suggested Method for Determination of Schmidt
Rebound Hardness.
5.3 Calibration Anvil— The standard calibration block used
to calibrate the rebound hammer.5.4 Abrasive Stone— A medium-grained texture silicon car-
bide or equivalent material.
6. Sampling
6.1 Drill core specimens shall be NX or larger core of at
least 15 cm in length. Block specimens shall have edge lengths
of at least 15 cm. Rock surfaces tested in place, including
natural outcrops or prepared surfaces such as tunnel walls or
floors, shall have a smooth, flat test area at least 15 cm in
diameter.
6.2 Samples shall be representative of the rock to be studied.
Obtain samples by direct sampling of subsurface rock unitswith core borings or by sampling blocks of rock material from
outcrops that correlate with the subsurface rock unit of interest.
At surface outcrops, avoid sampling and testing rock material
weakened by weathering or alteration or is otherwise unrepre-
sentative of the rock material of interest, see Suggested Method
for Quantitative Description of Discontinuities in Rock
Masses.
6.3 The rebound hammer is generally unsuitable for very
soft or very hard rock. Conduct simple field tests to quickly
assess a rock material’s suitability for the rebound hammer test
method. Scratch very soft rock with a fingernail and peel with
a pocket knife. An intact specimen of very hard rock breaks
only by repeated, heavy blows with a geological hammer and
cannot be scratched with a common 20d steel nail.
7. Specimen Preparation
7.1 For a block or core specimen, determine its length by
taking the average of four lengths measured at four equally
spaced points on the circumference and record to the nearest 5
mm.7.2 For a block or core specimen, determine its diameter by
taking the average of two diameters measured at right angles to
each other approximately midway along the length of the
specimen and record to the nearest 5 mm.
7.3 Report the moisture condition of the block or specimen.
7.4 The test surface of all specimens, either in the laboratory
or in the field, shall be smooth to the touch and free of joints,
fractures, or other obvious localized discontinuities to a depth
of at least 6 cm. In situ rock shall be flat and free of surface grit
over the area covered by the plunger. If the surface of the test
area is heavily textured, grind it smooth with the abrasive stone
described in 5.4.
8. Calibration
8.1 Prior to each testing sequence, calibrate the hammer
using a calibration test anvil supplied by the manufacturer for
that purpose.
8.1.1 Place the calibration anvil in the core holder and
conduct ten readings on the anvil.
8.1.2 Calculate the correction factor by dividing the manu-
facturer’s standard hardness value for the anvil by the average
of the ten readings taken on the anvil.
NOTE 3—If the instrument reads lower than the manufacturer’s standard
hardness value, the correction factor will be greater than unity. If thereadings are higher, the correction factor will be less than unity.NOTE 4—Operation of the rebound hammer is satisfactory if the
calibration readings fall within the range provided by the manufacturer. If the calibration readings fall outside this range, the instrument must becleaned, adjusted, or returned to the manufacturer for correction.
NOTE 5—Rebound hammers require periodic servicing and verificationto provide reliable results.
9. Procedure
9.1 Place the steel base on a flat, level surface that provides
firm, rigid support, such as a concrete floor.
9.2 Securely clamp rock core specimens in a steel cradle
with a semicylindrical machined slot of the same radius as the
core, or firmly seat into a steel V-shaped block. Securely clampblock specimens to the rigid steel base in such a manner as to
prevent vibration and movement of the specimen during the
test.
9.3 For tests conducted on specimens in the laboratory,
orient the instrument within 5° of vertical with the bottom of
the piston at right angles to and in firm contact with the surface
of the test specimen. A guide may be used to ensure the
rebound hammer is positioned for optimum performance.
Position the hammer not less than one diameter from the edge
of the specimen.
9.4 For tests conducted in situ on a rock mass, the rebound
hammer can be used at any desired orientation provided the
D5873 − 05
2Copyright by ASTM Int'l (all rights reserved);
http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/http://0.0.0.0/
8/18/2019 Astm d5873 Esclerometro
3/4
plunger strikes perpendicular to the surface tested. The results
are corrected to a horizontal or vertical position using the
correction curves provided by the manufacturer.
9.5 Before conducting the tests, ensure the hammer is at the
same temperature as the test specimens by exposing it to the
ambient environmental conditions of the test area (indoors or
outdoors) for at least 2 h.
9.6 Compress the hammer spring by gradually depressing
the plunger until the hammer is triggered and impact occurs.
9.7 Read and record the height of the plunger rebound to the
nearest whole number, as measured on an arbitrary scale of 10
to 100 divisions located on the side of the hammer, before
restoring the piston to its original extension. Repeat this
procedure at ten representative locations on the specimen. Test
locations shall be separated by at least the diameter of the
piston and only one test may be taken at any one point.
9.8 If a specimen breaks during rebound testing, energy is
absorbed during breakage and, consequently, the rebound
reading will be lower than had it not broken. Any individualimpact test that causes cracking or any other visible failure
shall cause that test and the specimen to be rejected.
9.9 Some factors that may affect the results of the test
include:
9.9.1 Rock at 0° C or less may exhibit very high rebound
values.
9.9.2 Temperature of the rebound hammer itself may affect
the rebound number. The hammer and materials to be tested
should be at the same temperature.
9.9.3 For readings to be compared, the direction of impact,
horizontal, upward, downward, and so forth, must be the same.
9.9.4 Different hammers of the same nominal design may
give rebound numbers differing from one to three units andtherefore, tests should be made with the same hammer in order
to compare results. If more than one hammer is to be used, a
sufficient number of tests must be made on typical rock
surfaces to determine the magnitude of the differences to be
expected.
10. Calculation
10.1 Using the data from the ten readings obtained in 9.7,
discard readings differing from the average of ten readings by
more than seven units and determine the average of the
remaining readings. To calculate the rebound hardness number
( H R
) of the tested rock material, multiply this average by the
correction factor determined in 8.1.2 and record the results to
the nearest whole number.
11. Report
11.1 Report the following minimum information for each
specimen or test area:
11.1.1 Source of samples, including geographic location;
boring number, depth, orientation, and stationing; and rock
type,
11.1.2 Weathering and alteration condition of samples, par-
ticularly when sampling a surface outcrop,
11.1.3 Type of specimen (core, block, or in situ); size and
shape of specimen; and, if block type, whether cut or blasted,
11.1.4 Date of sampling and date of testing,
11.1.5 Storage conditions of samples (for example, expo-
sure to temperature extremes, air drying, and moisture
changes),
11.1.6 Type and model number of hammer,
11.1.7 Orientation of the plunger axis during the test,
11.1.8 Method of securing the sample (for example,
V-block, or clamps),
11.1.9 Number of tests conducted,
11.1.10 Temperature of site at time of test, and
11.1.11 The individual and average values of hammer re-
bound, the value of the correction factor, and the rebound
hardness number, H R
(obtained in 10.1).
12. Precision and Bias
12.1 Precision— No data exist to determine the precision of
this test method in determining rock hardness.
12.2 Bias— There is no accepted standard value for H R
for
any material, therefore bias cannot be determined.
13. Keywords
13.1 core; hardness; rock mass; rock; unconfined compres-
sive strength
D5873 − 05
3Copyright by ASTM Int'l (all rights reserved);
8/18/2019 Astm d5873 Esclerometro
4/4
SUMMARY OF CHANGES
In accordance with Committee D18 policy, this section identifies the location of changes to this standard since
the last edition (00(2005)) that may impact the use of the standard.
(1) Deleted Test Method D2938 in Sections 1.2 and 2.1, and
replaced with Test Method D7012.
ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentioned
in this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the risk
of infringement of such rights, are entirely their own responsibility.
This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years and
if not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standards
and should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of the
responsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you should
make your views known to the ASTM Committee on Standards, at the address shown below.
This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,
United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the above
address or at 610-832-9585 (phone), 610-832-9555 (fax), or [email protected] (e-mail); or through the ASTM website
(www.astm.org). Permission rights to photocopy the standard may also be secured from the ASTM website (www.astm.org/
COPYRIGHT/).
D5873 − 05
4Copyright by ASTM Int'l (all rights reserved);
Top Related