ObjectiveIntroduction
ContentsRequirements for the accredition of water analysislaboratoriesMinimum equipments for each service.Minimun required refference for laboratory.SynthesisEvaluation
7/31/2019 MTLBE Report. Pueblo JAD
4/49
After completion of this lesson our classmateswill be able to:
explain the importance of water testinglaboratories.identify the standard laboratory proceduresin the examination of drinking water.enumerate the requirements foraccreditation of water analysis laboratories.
7/31/2019 MTLBE Report. Pueblo JAD
5/49
-PD 866 (Code of sanitation of Philippines)
-Examination of drinking water ---Department of Health.
7/31/2019 MTLBE Report. Pueblo JAD
6/49
January 1968 (Ministry of HumanSettlements and Ecology)
-published a three- volume PhilippineStandards Methods for Air and WaterAnalysis September 1978 (Ministry of Health)-issued a revised National Standards forDrinking Water
7/31/2019 MTLBE Report. Pueblo JAD
7/49
-assurance that accepted procedures
available for determination of STANDARD
-adherence to the procedures allowscomparability of results of analysis within asingle laboratory and between laboratories.
7/31/2019 MTLBE Report. Pueblo JAD
8/49
Water analysis laboratories maybeaccredited for separate services like:
BacteriologicalChemicalRadiologicalBiological
7/31/2019 MTLBE Report. Pueblo JAD
9/49
Name, citizenship and domicile of the head of the laboratoryMunicipality and where it is establishedName of establishmentName, citizenship and domicile of ownerScope and nature of work, specifying procedures
Statement that applicant has complied with allbusiness requirements
Tax clearance for proceeding year
7/31/2019 MTLBE Report. Pueblo JAD
10/49
sanitary engineer .In areas where there may not be a licensed
sanitary engineer,licensed chemistmedical technologist
pharmacist
7/31/2019 MTLBE Report. Pueblo JAD
11/49
headmanageor supervise up to 3 waterlaboratories
7/31/2019 MTLBE Report. Pueblo JAD
12/49
technical aspect:physical bacteriological,
chemical,biological and radiological examinations of water ,
should be a registered: pharmacist,medical technologist,or chemist.
7/31/2019 MTLBE Report. Pueblo JAD
13/49
must have been trained and musthave at least 1 year experience.
may supervise not more than two
skilled workers .
7/31/2019 MTLBE Report. Pueblo JAD
14/49
Laboratory support personnelsuch as;laboratory aides - are needed to clean glassware's, assist in thepreparation of media.
Each service must therefore be operated by at least oneregistered professional, one laboratory aide .
Bacteriological service-----handle at most 30 samples/day
Chemical service -----5 samples for routine chemistry .
7/31/2019 MTLBE Report. Pueblo JAD
15/49
Work rooms must be:house in a permanent buildingWell-ventilated
correlate with the volume and type of workA bench height of 90 cm providesconvenience for workers
adequate running water.Adequate physical provisions for the safetyof the laboratory personnel must beprovided.
7/31/2019 MTLBE Report. Pueblo JAD
16/49
7/31/2019 MTLBE Report. Pueblo JAD
17/49
Quality -to meet the levels of sensitivity,reliability and should only need
minimum service repair.Increased workloadEfficiency and effectively.Highest grade of quality media andreagent are to be used
7/31/2019 MTLBE Report. Pueblo JAD
18/49
A. bacteriological Analysis Service
B. biological Analysis Service
C. Physical and Chemical Analysis Services
D. Radiologic Analysis Service
7/31/2019 MTLBE Report. Pueblo JAD
19/49
7/31/2019 MTLBE Report. Pueblo JAD
20/49
Multiple-tube fermentation technique
7/31/2019 MTLBE Report. Pueblo JAD
21/49
IMVIC test Standard plate count
7/31/2019 MTLBE Report. Pueblo JAD
22/49
Fecal coliform test Optional-test for fecal streptococcal group
7/31/2019 MTLBE Report. Pueblo JAD
23/49
7/31/2019 MTLBE Report. Pueblo JAD
24/49
7/31/2019 MTLBE Report. Pueblo JAD
25/49
7/31/2019 MTLBE Report. Pueblo JAD
26/49
7/31/2019 MTLBE Report. Pueblo JAD
27/49
ColorOdorPh valueSpecific conductanceTasteTemperatureTurbidityTotal solidsHardness
AcidityAlkalinityAluminumArsenicBariumCadmiumCalcium free CO2ChlorideChlorine (residual)
TEST FOR
7/31/2019 MTLBE Report. Pueblo JAD
28/49
Chromium(hezavalent)CopperCyanideFluorideIronLeadMagnesiumManganeseMercury
Nitrogen, ammoniaNitrogen nitrateOil and greaseTotal organic carbonOxygen, dissolvedOxygen, demand,biochem.PesticidesPhenolsPhospahate
7/31/2019 MTLBE Report. Pueblo JAD
29/49
PotassiumResidueSeleniumSilica, dissolvedSilver
SodiumSulfateSulfideSulfiteSurfactantzinc
7/31/2019 MTLBE Report. Pueblo JAD
30/49
7/31/2019 MTLBE Report. Pueblo JAD
31/49
7/31/2019 MTLBE Report. Pueblo JAD
32/49
Total radioactive strontium in H2O
Strontium --- 90 in H2OTotal Radium (Precipitation Technique)Radium ---- 266 by Radon (Soluble, suspendedand Total)
7/31/2019 MTLBE Report. Pueblo JAD
33/49
7/31/2019 MTLBE Report. Pueblo JAD
34/49
IncubatorWaterbath, 37C45C 0.5(Escherichia coli test is to be performed)
AutoclavepH meterAnalytical balanceColony counter
MicroscopeHot plate/stoveBunsen burnerRefrigerator
7/31/2019 MTLBE Report. Pueblo JAD
35/49
Incubator
Waterbath
7/31/2019 MTLBE Report. Pueblo JAD
36/49
Autoclave
pH meter
7/31/2019 MTLBE Report. Pueblo JAD
37/49
Analytical balance
Hot plate/stove
7/31/2019 MTLBE Report. Pueblo JAD
38/49
7/31/2019 MTLBE Report. Pueblo JAD
39/49
Bunsen burner
Refrigerator
7/31/2019 MTLBE Report. Pueblo JAD
40/49
pH meterOven sterilizingCandle turbidimeter
Pipette washerSpectrophotometer, spectronic 20, or AAMagnetic stirrerWaterbathRefrigeratorGas chromatographerVacuum filter
7/31/2019 MTLBE Report. Pueblo JAD
41/49
Oven sterilizing
Candle turbidimeter
7/31/2019 MTLBE Report. Pueblo JAD
42/49
Pipette washer
Spectrophotometer
Magnetic stirrer
7/31/2019 MTLBE Report. Pueblo JAD
43/49
Gas chromatographer Vacuum filter
7/31/2019 MTLBE Report. Pueblo JAD
44/49
1. Water sampler, any of the following:a. Van dornb. Kemmerrerc. Wansend. Buttnere. Improvised Neyer or LLDAs Modifier
Sampler2. Water pump with graduated intake3. Bottom drodge4. Inverted microscope5. Compound microscope
7/31/2019 MTLBE Report. Pueblo JAD
45/49
Bottom dredge
Inverted microscope
7/31/2019 MTLBE Report. Pueblo JAD
46/49
7/31/2019 MTLBE Report. Pueblo JAD
47/49
a. Philippine Standard Methods for Air andWater Analysis, vol.1 and vol.2, HumanSettlements Commission, January 1978Standard Methods for the Examination of Water and Wastewater: APHA, AWWA,WFCF, 14th edition.
National Standards for Drinking Water,Bureau of Research and Laboratories,Ministry of Health, 1978.
7/31/2019 MTLBE Report. Pueblo JAD
48/49
7/31/2019 MTLBE Report. Pueblo JAD
49/49
In every glass of water we drink, some of the water has already passed through fishes, trees, bacteria,
worms in the soil, and many other organisms,including people...Living systems cleanse water and
make it fit, among other things, for humanconsumption.
ELLIOT A. NORSE