Memoria de Calculo Ins Sanitarias

Post on 12-Dec-2015

20 views 5 download

description

mm

Transcript of Memoria de Calculo Ins Sanitarias

MEMORIA DE CÁLCULO SISTEMA DE AGUA PROYECTO MEJORAMIENTO DEL SERVICIO EDUCATIVO EN LA INSTITUCION EDUCATIVA N° 206 – TRUJILLO

Aulas (01 al 09) 1 225 225 alumnos Numeral 2.2 letra d 50.00 lts/dia x alumno 11,250.00Guardiania 1 1 1 departamentos Numeral 2.2 letra b 500.00 lts/dia/dep. 500.00Area Verdes 1 1 1 m2 239.90 Numeral 2.2 letra u 2.00 lts/dia/dep. 479.80Topico 1 1 1 consultorio Numeral 2.2 letra s 500.00 lts/dia/m2 500.00Deposito 1 1 1 m2 5.43 Numeral 2.2 letra j 0.50 lts/dia/m2 500.00Botadero 1 1 1 m2 5.43 Numeral 2.2 letra j 0.50 lts/dia/m2 500.00S.U.M. 1 1 1 1 asientos 33.00 Numeral 2.2 letra f 3.00 lts/dia/asiento 99.00S.U.M. 2 1 1 1 asientos 33.00 Numeral 2.2 letra f 3.00 lts/dia/asiento 99.00S.U.M. 3 1 1 1 asientos 33.00 Numeral 2.2 letra f 3.00 lts/dia/asiento 99.00Sala de Profesores 1 1 1 m2 16.20 Numeral 2.2 letra i 6.00 lts/dia/m2 97.20Psicologia 1 1 1 m2 7.04 Numeral 2.2 letra i 6.00 lts/dia/m2 42.24Secretaria y Sala de Espera 1 1 1 m2 10.73 Numeral 2.2 letra i 6.00 lts/dia/m2 64.40Direccion 1 1 1 m2 7.55 Numeral 2.2 letra i 6.00 lts/dia/m2 45.32Deposito 1 1 1 m2 4.37 Numeral 2.2 letra j 0.50 lts/dia/m2 500.00

Fuente: RNE - Cap III.3. INSTALACIONES SANITARIAS Qp= 0.17 lpsCap III.3. Norma IS.010 VOLUMEN DEMANDA DIARIA (VDD)= 14,775.95 lts/dia

14.78 m3/dia

item RNE DOT. DIARIA

UNIDAD DOT. PARCIAL (lts)

CALCULO DEL VOLUMEN DEMANDA DIARIAAGUA FRIA SISTEMA PROYECTADO

NIVELES AMBIENTES Nº NIVELES

1° PISO

2° PISO

CANT. UNIDAD AREA (M2)CANT. POR NIVEL

CÁLCULO VOLUMENES DE ALAMACENAMIENTO SISTEMA DE AGUA PROYECTO MEJORAMIENTO DEL SERVICIO EDUCATIVO EN LA INSTITUCION EDUCATIVA N° 206 - TRUJILLO

VOLUMEN CISTERNA CONSUMO DOMESTICO (3/4*VDD) = 11,082 lts Largo 1 = 3.0011.08 m3 Ancho 1= 2.00

VOLUMEN CISTERNA PROYECTO NUEVO = 12.00 m3 Altura 1 = 2.00VOLUMEN CISTERNA CONSUMO HUMANO = 12.00 m3 Volumen 1= 12

TOTAL VOLUMEN TOTAL CISTERNA = VCH + VSCI 12.00 m3 Vol. Total Cisterna= 12 m3

VOLUMEN TANQUE ELEVADO CONSUMO DOMESTICO (1/3*VDD) = 4,925 lts4.93 m3 Largo 1 = 2.00

VOLUMEN TANQUE ELEVADO PROYECTO NUEVO = 4.93 m3 Ancho 1= 1.70VOLUMEN TANQUE ELEVADO CONSUMO HUMANO = 5.00 m3 Altura 1 = 1.47

Volumen 1= 5

Fuente: RNE - Cap III.3. INSTALACIONES SANITARIAS Vol. Total Cisterna= 5 m3Cap III.3. Norma IS.010

DIMENSION VOL. TANQUE ELEVADO CONSUMO HUMANO

DIMENSION VOL. CISTERNA CONSUMO HUMANO

CALCULO DE VOLUMENES DE ALMACENAMIENTO POR SISTEMA INDIRECTO CISTERNA Y TANQUE ELEVADO

CÁLCULO MAXIMA DEMANDA SIMULTANEA SISTEMA DE AGUA PROYECTO MEJORAMIENTO DEL SERVICIO EDUCATIVO EN LA INSTITUCION EDUCATIVA N° 206 - TRUJILLO

D1PRIV PUB PRIV PUB PRIV TQUE VALV TQUE VALV

INODORO Privado 1 5 3 0 0 3 0LAVATORIO Privado 1 2 1 0 0 0 1DUCHA Privado 1 4 2 0 0 0 2INODORO Publico 2 5 3 0 0 10 0LAVATORIO Publico 2 2 1 0 0 0 4URINARIO Publico 2 3 3 0 0 0 6INODORO Publico 2 5 3 0 0 10 0LAVATORIO Publico 2 2 1 0 0 0 4INODORO Publico 3 5 3 0 0 15 0LAVATORIO Publico 3 2 1 0 0 0 6URINARIO Publico 2 3 3 0 0 0 6INODORO Publico 3 5 3 0 0 15 0LAVATORIO Publico 3 2 1 0 0 0 6INODORO Publico 3 5 3 0 0 15 0LAVATORIO Publico 3 2 1 0 0 0 6URINARIO Publico 2 3 3 0 0 0 6INODORO Publico 3 5 3 0 0 15 0LAVATORIO Publico 3 2 1 0 0 0 6INODORO Privado 1 5 3 0 0 3 0LAVATORIO Privado 1 2 1 0 0 0 1URINARIO Privado 1 3 3 0 0 0 3INODORO Privado 1 5 3 0 0 3 0LAVATORIO Privado 1 2 1 0 0 0 1

3 LAVATORIOS AULAS 1-3 LAVATORIO Privado 3 2 1 0 0 0 33 LAVATORIOS AULAS 4-6 LAVATORIO Privado 3 2 1 0 0 0 33 LAVATORIOS AULAS 7-9 LAVATORIO Privado 3 2 1 0 0 0 31 TOPICO LAVATORIO Privado 1 2 1 0 0 0 11 BOTADERO LAVADERO Privado 2 3 3 0 0 0 69 AREAS VERDES GRIFO DE RIEGO Privado 9 2 2 0 0 0 18

INODORO Privado 1 5 3 0 0 3 0LAVATORIO Privado 1 2 1 0 0 0 1

TOTAL PISO 92 93 1.58 2.48

N1 92 93 1.58 2.48

92.00 93.00 1.58 2.48

NUMERO UNIDADES DE GASTO

GASTOS PROBABLES (HUNTER)

D1 D1

N° PisoNº Dptos

TipoSS. HH./TRAMO DE

TUBERIAAPARATOS USO

UNIDADES DE GASTO

AF AC

CANTIDAD APARATOS

1 SS. HH. NIÑOS A

1 SS. HH. NIÑAS A

1 GUARDIANIA

1 SS. HH. NIÑOS C

1 SS. HH. NIÑAS C

1 SS. HH. NIÑOS B

1 SS. HH. NIÑAS B

TOTAL UNIDADES DE GASTO EN VALVULAS Y GASTO PROBABLE EN DISTRIBUIDORA PRINCIPAL (D1) 93.00 2.48

4.06

1SS. HH. DOCENTES

VARONES

TOTAL UNIDADES DE GASTO Y GASTO PROBABLE EN DISTRIBUIDORASTOTAL GASTO PROBABLE EN DISTRIBUIDORAS

1

CALCULO DE LA MAXIMA DEMANDA SIMULTANEA SISTEMA DE AGUA POTABLE

TOTAL GASTO EN DISTRIBUIDORA PRINCIPAL (MDS=D1) 4.06

TOTAL UNIDADES DE GASTO EN TANQUES Y GASTO PROBABLE EN DISTRIBUIDORA PRINCIPAL (D1)

2DO PISO SS.HH. DIRECCION

1ER PISO

1 SS. HH. DOCENTES DAMAS

92.00 1.58

3

4

6 11 12 13 18

CÁLCULO HIDRAULICO RED DE DISTRIBUCION SISTEMA DE AGUA PROYECTO MEJORAMIENTO DEL SERVICIO EDUCATIVO EN LA

INSTITUCION EDUCATIVA N° 206 - TRUJILLO

1º ) CALCULO DEL CAUDAL DE BOMBEO AGUA

Caudal Maxima Demanda Simultanea (MDS)

Qmds = 4.06 lpsQmds = 0.0041 m3/seg

2º ) CALCULO DEL DIAMETRO ECONOMICO DE LA LINEA DE IMPULSION

En instalaciones de funcionamiento discontínuo :Dec = 1.3* ((N/24) ^0.25)*( Q m3 /seg) ^ (0.5)donde X = ( horas de funcionamiento / 24 )

En este caso : Dec = 0.070 m2.74 pulgs

3º ) CALCULO DE ALTURA DINAMICA DE EQUIPO DE BOMBEO AGUA

Hdt =hf + hacc + H geom + P llegada P llegada= 2.00 m

3.1.- Cálculo de las pérdidas de carga por friccion en Tuberias - Líneas de Succion e Impulsion

3.1.1.- Tramo 01 - Linea de Succion

CAUDAL = 4.06 lps 2.03

DIAMETRO ( D )= 3 pulgs 2

VELOCIDAD ( m/s )= 0.89 m/s 1.00

Longitud ( L ) = 3.00 m 3.00

C Hazen ( C ) = 100 FºGº 100

3.1.2.- Tramo 02 - Linea de Impulsion

CAUDAL = 4.06 lps 2.03 lps

DIAMETRO ( D )= 2 pulgs 1 1/2 pulg.

VELOCIDAD ( m/s )= 2.00 m/s 1.78 m/s

PERDIDA DE CARGA Total = 3.23 m

3.3.- Cálculo de la Altura geométrica

Cota de llegada a Tanque Elevado= 9.21

Cota del nivel Canastilla Succion = -2.94

Desnivel geométrico = 12 m

Hdt =hf + hacc + H geom + P llegada = 17 m

4º ) CALCULO DE LA POTENCIA DEL EQUIPO DE BOMBEO DE AGUA

Pot = Hdt * Q b * Peso específico agua / n * 70

n = Eficiencia de la bomba = 0.60

Peso específico agua = 1

Qb = Caudal de bombeo = 4.06 lps Qb= 2.03 lps

0.0041 m3 /segHdt = Altura dinámica total = 17 m HDT= 17 m

Pot = 1.96 HP Pot = 0.98 HP

Pot. Comercial = 2.00 HP Pot. Com. = 1.00 HP

CALCULO DEL EQUIPO DE BOMBEO DEL SISTEMA DE AGUA DE CONSUMO DOMESTICO

OPTAMOS 2 EQUIPOS DE

BOMBEO + 1 stand by

CALCULO DEL DIAMETRO DEL MEDIDOR:El Caudal de ingreso a la cisterna para el Sistema Indirecto se calcula así: Q=V/T Donde: V=12.00m3 T=4horas

→ Q = 12,000.00/21,600 = 0.83 lts/seg. 3.00 M3/Hr.11.00 G.P.M.

Luego se calcula la carga disponible:

H = PR – PS - HT

Donde: H = Carga disponible PR = Presión en la red = 10.00 mca (como minimo de acuerdo PS = Presión a la salida 3.50 mca al RNE) HT = Altura Red a Cisterna 0.10 m H = 10.00x1.42 - 5 – 0.10x1.42 = 9.06 libras/pulg.2

= 6.34 m.c.a.

La selección del medidor se realiza tomando en cuenta la máxima pérdida de carga del medidor, el 50% de la carga disponible, entonces se tiene:

Hmedidor = 0.5x9.06 = 4.53 libras/pulg.2= 3.17 m.c.a.

En el ábaco de medidores se tiene:

DIAMETRO PERDIDA DE CARGA5/8” 10.50 libras/pulg.2 (7.15mca)3/4” 3.80 libras/pulg.2 (2.66mca)1” 1.70 libras/pulg.2 (1.18mca)

11/2” 0.15 libras/pulg.2 (0.1mca)

Por lo tanto seleccionamos el medidor de 3/4”

SELECCIÓN DEL DIAMETRO DE TUBERIA DE INGRESO DE LA RED PÚBLICA A LA CISTERNA:Como el medidor ocasiona una pérdida de carga de 3.8 libras/pulg.2, equivalente a 2.66 mca, la nueva carga disponible será:

→ Hdisponible = 9.06 - 3.8 = 5.26 libras/pulg.2= 3.68 m.c.a.

Asumiendo un diámetro de 1”Longitud equivalente por accesorios:

Accesorios Longitud Equivalente2 válvula de paso 1” 0.432Red 1"x3/4" 0.431 válvula Compuerta 1” 0.222 codos de 45º 1” 1.551 codos de 90º 1” 4.09Total 6.73

Longitud de tuberia = 11.74Longitud equivalente = 6.73Luego la longitud total es de = 4.00m. + 6.73m. = 18.47 m.De acuerdo al ábaco:

Q = 0.83 lpsC = 150 √pie/seg PVCD = 1 pulgadas 0.03 m.V = 1.23 m/s.S = 116.05 ‰

Luego Hf = 0.11605 x 18.47 = 2.14 m.Como: Hf = 2.14 < Hdisponible = 3.68Por lo tanto seleccionamos la Tuberia de Ingreso de 1” PVC

CALCULO ACOMETIDA AGUA POTABLE (ALIMENTACION DE AGUA TRAMO CAJA PORTAMEDIDOR-CISTERNA)

L Q C D S Lequiv. hf CPI CPF CT P V Dcomercialm m3/s m m/m m m m m m m m/s pulg

Man Suc-1 3.24 0.0020 100 0.050 0.047291 2.91 0.29 14.44 14.15 0.22 13.93 1.03 2"2 1 - 2 0.50 0.0020 100 0.040 0.140206 1.40 0.27 14.15 13.89 0.78 13.11 1.62 11/2"3 2 - 3 8.68 0.0041 100 0.050 0.170703 7.00 2.68 13.89 11.21 9.21 2.00 2.07 2"

3.23

CALCULO HIDRAULICO DE LA LINEA DE IMPULSION c/perdida en ACCESORIOS

Nudo Tramo

L Q C D S Lequiv. hf CPI CPF CT P V Dcomercialm m3/s m m/m m m m m m m m/s pulg

5 4 - 5 8.80 0.0041 150 0.080 0.008116 12.27 0.17 8.25 8.08 0.00 8.08 0.81 3"6 5 - 6 7.50 0.0039 150 0.080 0.007678 9.20 0.13 8.08 7.95 0.00 7.95 0.78 3"7 6 - 7 5.30 0.0038 150 0.080 0.007215 6.14 0.08 7.95 7.87 0.00 7.87 0.76 3"8 7 - 8 1.40 0.0035 150 0.054 0.041804 4.52 0.25 7.87 7.62 0.00 7.62 1.53 2"9 8 - 9 4.30 0.0033 150 0.054 0.037389 4.09 0.31 7.62 7.31 0.00 7.31 1.44 2"

10 9 - 10 9.50 0.0033 150 0.054 0.037097 4.09 0.50 7.31 6.80 0.00 6.80 1.43 2"11 10 - 11 2.70 0.0033 150 0.054 0.036806 4.09 0.25 6.80 6.55 0.00 6.55 1.43 2"12 11 - 12 0.70 0.0033 150 0.054 0.036228 4.09 0.17 6.55 6.38 0.00 6.38 1.41 2"13 12 - 13 4.00 0.0023 150 0.054 0.019528 4.09 0.16 6.38 6.22 0.00 6.22 1.01 2"14 13 - 14 1.75 0.0022 150 0.054 0.018082 4.09 0.11 6.22 6.12 0.00 6.12 0.97 2"15 14 - 15 9.50 0.0022 150 0.054 0.017122 4.09 0.23 6.12 5.88 0.00 5.88 0.94 2"16 15 - 16 9.30 0.0022 150 0.054 0.016832 4.09 0.23 5.88 5.66 0.00 5.66 0.93 2"17 16 - 17 13.60 0.0021 150 0.054 0.016544 4.09 0.29 5.66 5.36 0.00 5.36 0.93 2"18 17 - 18 3.65 0.0019 150 0.054 0.012816 6.14 0.13 5.36 5.24 0.00 5.24 0.81 2"19 18 - 19 7.50 0.0007 150 0.029 0.040182 9.64 0.69 5.24 4.55 0.00 4.55 1.02 1"T1 19- T1 0.70 0.0006 150 0.029 0.034957 2.05 0.10 4.55 4.45 0.00 4.45 0.94 1"T2 T1- T2 0.70 0.0006 150 0.029 0.030542 2.05 0.08 4.45 4.37 0.00 4.37 0.88 1"T3 T2- T3 0.50 0.0006 150 0.029 0.027299 2.05 0.07 4.37 4.30 0.00 4.30 0.82 1"T4 T3 - T4 0.60 0.0005 150 0.029 0.022131 2.05 0.06 4.30 4.24 0.00 4.24 0.74 1"T5 T4 - T5 3.45 0.0004 150 0.023 0.058977 2.50 0.35 4.24 3.89 0.00 3.89 1.07 3/4"T6 T5 - T6 0.80 0.0004 150 0.023 0.056519 1.72 0.14 3.89 3.75 0.00 3.75 1.04 3/4"I T6 - I 1.30 0.0002 150 0.017 0.067599 1.60 0.20 3.75 3.55 0.30 3.25 0.97 1/2"

4.70

T: Tee Nivel de Fondo del Tanque Elevado es = 7.50C: Codo 90°D. Ducha

CALCULO HIDRAULICO DEL NIVEL DE FONDO DEL TANQUE ELEVADO, DISTRIBUIDORA D-1

LEYENDA

Nudo Tramo

MEMORIA DE CALCULO SISTEMA DE DESAGUE

M1 RedPRIV Interior PRIV PUB PRIV PUB PRIV PUB

INODORO Privado 0 1 4 4 0 0 4 0LAVATORIO Privado 0 1 1 2 0 0 1 0DUCHA Privado 0 1 2 3 0 0 2 0INODORO Publico 0 2 4 4 0 0 0 8LAVATORIO Publico 0 2 1 2 0 0 0 4URINARIO Publico 0 2 4 4 0 0 0 8INODORO Publico 0 2 4 4 0 0 0 8LAVATORIO Publico 0 2 1 2 0 0 0 4INODORO Publico 0 3 4 4 0 0 0 12LAVATORIO Publico 0 3 1 2 0 0 0 6URINARIO Publico 0 2 4 4 0 0 0 8INODORO Publico 0 3 4 4 0 0 0 12LAVATORIO Publico 0 3 1 2 0 0 0 6INODORO Publico 0 3 4 4 0 0 0 12LAVATORIO Publico 0 3 1 2 0 0 0 6URINARIO Publico 0 2 4 4 0 0 0 8INODORO Publico 0 3 4 4 0 0 0 12LAVATORIO Publico 0 3 1 2 0 0 0 6INODORO Privado 0 1 4 4 0 0 4 0LAVATORIO Privado 0 1 1 2 0 0 1 0URINARIO Privado 0 1 4 4 0 0 4 0INODORO Privado 0 1 4 4 0 0 4 0LAVATORIO Privado 0 1 1 2 0 0 1 0

3 LAVATORIOS AULAS 1-3 LAVATORIO Privado 0 3 1 2 0 0 3 03 LAVATORIOS AULAS 4-6 LAVATORIO Privado 0 3 1 2 0 0 3 03 LAVATORIOS AULAS 7-9 LAVATORIO Privado 0 3 1 2 0 0 3 01 TOPICO LAVATORIO Privado 0 1 1 2 0 0 1 01 BOTADERO LAVADERO Privado 0 2 2 2 0 0 4 0

INODORO Privado 1 1 4 4 4 0 4 0LAVATORIO Privado 1 1 1 2 2 0 1 0

1 TOTAL PISO 6 0 40 1206 160 100(4")

SEGÚN RNE EN TUBERIAS DE 150(6") Y CON PENDIENTE S=1%EL MAXIMO DE UNIDADES DE DESCARGA ES DE 700SELECCIONAMOS Ø 150MM (6")

ØPROBABLE DE CONDUCTO HORIZONTAL S=1%, 4" HASTA 160 DESCARGAS

CALCULO UNIDADES DE DESCARGA SISTEMA DE DESAGUE

166

N° PISONº DPTOS

TIPO SSHH/TRAMO DE TUBERIA APARATOS USO

CANTIDAD APARATOS

TOTAL UNIDADES DE DESCARGA COLECTOR (M1+Red Interior)

6"

SS. HH. NIÑAS B

1 SS. HH. NIÑOS C

1 SS. HH. NIÑAS C

1SS. HH. DOCENTES

VARONES

1SS. HH. DOCENTES DAMAS

DIAMETRO DEL COLECTOR (M1+Red Interior)

1 SS. HH. NIÑAS A

1 SS. HH. NIÑOS B

1

2DO PISO 1 SS.HH. DIRECCION

Red Interior

TOTAL UNIDADES DE DESCARGA POR MONTANTE

1ER PISO

1 GUARDIANIA

1 SS. HH. NIÑOS A

UNIDADES DESCARGA

M1

TOTAL UNIDADES DESCARGA

1 CR9 CR10 3.34 55.86 55.86 55.46 55.42 0.40 0.44 1.20 4" 1° piso2 CR10 CR11 13.58 55.86 55.86 55.42 55.28 0.44 0.58 1.03 4" 1° piso3 CR11 CR12 9.27 55.86 55.86 55.28 55.18 0.58 0.68 1.08 4" 1° piso4 CR12 CR13 9.08 55.86 55.86 55.18 55.08 0.68 0.78 1.10 4" 1° piso5 CR13 CR18 5.00 55.86 55.86 55.08 55.03 0.78 0.83 1.00 4" 1° piso6 CR18 CR19 8.61 55.86 55.86 55.03 54.94 0.83 0.92 1.05 4" 1° piso7 CR19 CR20 8.61 55.86 55.86 54.94 54.85 0.92 1.01 1.05 4" 1° piso8 CR20 CR21 5.60 55.86 55.86 54.85 54.79 1.01 1.07 1.07 6" 1° piso9 CR21 CR23 4.48 55.86 55.86 54.79 54.74 1.07 1.12 1.12 6" 1° piso

10 CR23 Bzta01 2.00 55.86 55.86 54.74 54.72 1.12 1.14 1.00 6" 1° piso11 CR22 CR23 3.35 55.86 55.86 55.36 55.32 0.50 0.54 1.19 4" 1° piso12 CR14 CR15 3.27 55.86 55.86 55.46 55.42 0.40 0.44 1.22 4" 1° piso13 CR15 CR16 13.58 55.86 55.86 55.42 55.28 0.44 0.58 1.03 4" 1° piso14 CR16 CR17 9.27 55.86 55.86 55.28 55.18 0.58 0.68 1.08 4" 1° piso15 CR17 CR18 9.08 55.86 55.86 55.18 55.08 0.68 0.78 1.10 4" 1° piso16 CR01 CR02 13.45 55.86 55.86 55.56 55.42 0.30 0.44 1.04 4" 1° piso17 CR02 CR03 9.50 55.86 55.86 55.42 55.32 0.44 0.54 1.05 4" 1° piso18 CR03 CR04 3.88 55.86 55.86 55.32 55.28 0.54 0.58 1.03 4" 1° piso19 CR04 CR05 3.23 55.86 55.86 55.28 55.24 0.58 0.62 1.24 4" 1° piso20 CR05 CR06 3.12 55.86 55.86 55.24 55.20 0.62 0.66 1.28 4" 1° piso21 CR06 CR07 2.37 55.86 55.86 55.20 55.17 0.66 0.69 1.27 4" 1° piso22 CR07 CR08 3.64 55.86 55.86 55.17 55.13 0.69 0.73 1.10 4" 1° piso23 CR08 CR23 5.52 55.86 55.86 55.13 55.07 0.73 0.79 1.09 4" 1° piso23 Caja Purga CR08 0.90 55.86 55.86 55.51 55.50 0.35 0.36 1.11 4" 1° piso24 Bzta Empalme 12.59 55.86 55.71 54.72 54.53 1.14 1.18 1.51 6" Via

CALCULO HIDRAULICO COLECTORES INTERIORES DE DESAGUE

Tramo

TramoLongitud

(ml)

Cota de Tapa Cota de Fondo ProfundidadS (%)

Diametro segun RNE (IS.010 Anexo N° 9)

UbicaciónAguas Arriba

Aguas Abajo

Caja Registro

Caja Registro

Aguas Arriba

Aguas Abajo

Aguas Arriba

Aguas Abajo

CALCULO SISTEMA DRENAJE PLUVIAL

CALCULO HIDRAULICO CANAL AGUAS PLUVIALES

Nº Tramo

TramoLongitud

(ml)

Cota de Tapa Cota de Fondo Profundidad

S (%)Ancho Canal

(m)Punto Aguas Arriba

Punto Aguas Abajo

Aguas Arriba

Aguas Abajo

Aguas Arriba

Aguas Abajo

Aguas Arriba

Aguas Abajo

1 2 1 19.42 55.86 55.86 55.76 55.70 0.10 0.16 0.31 0.302 2 3 19.42 55.86 55.86 55.76 55.70 0.10 0.16 0.31 0.303 1 Salida 1 2.22 55.86 55.86 55.70 55.69 0.16 0.17 0.45 0.304 3 Salida 2 3.12 55.86 55.86 55.70 55.69 0.16 0.17 0.32 0.305 4 5 18.00 55.86 55.86 55.76 55.70 0.10 0.16 0.33 0.306 5 Salida 3 4.40 55.86 55.86 55.70 55.68 0.16 0.18 0.45 0.30

I. CALCULO SECCION CANAL RECTANGULAR DRENAJE PLUVIAL MODULO Aulas 01-03

Remplazando estos valores, tenemos que:

Asumimos un valor de b = 0.30 m.

Q = 0.010 m³/s

s = 0.003

n = 0.014 Revestido de concreto

A = b * Yn

P = b + 2Yn

Q * n / (s ^0.5) = A * (R ^ 2/3) = [A ^ 5/3] / [P ^ 2/3]

0.003 = [ ( b*Yn)^ 5/3] / [ (b + 2Yn)^ 2/3]

Iterando :

Yn = 0.07 m

Yn = 0.07 m

Con este valor remplazamos en las formulas y se tiene .

Area (m²) = 0.02

Perim (m) = 0.44

Rad H. (m) = 0.05

Velocidad = 0.50 m/s

h v = 0.01 m.

E = Yn + hv = 0.08 m.

Calculo de borde Libre .

BL = Yn /3 = 0.023 m.

Usaremos : BL = 0.02 m

Resultados:

B.L. 0.02 m. 0.09 m.

Yn 0.07 m.b = 0.30 m.

II. CALCULO SECCION CANAL RECTANGULAR DRENAJE PLUVIAL PATIO

Remplazando estos valores, tenemos que:

Asumimos un valor de b = 0.30 m.

Q = 0.009 m³/s

s = 0.00300

n = 0.014 Revestido de concreto

A = b * Yn

P = b + 2Yn

Q * n / (s ^0.5) = A * (R ^ 2/3) = [A ^ 5/3] / [P ^ 2/3]

0.002 = [ ( b*Yn)^ 5/3] / [ (b + 2Yn)^ 2/3]

Iterando :

Yn = 0.06 m

Yn = 0.06 m

Con este valor remplazamos en las formulas y se tiene .

Area (m²) = 0.02

Perim (m) = 0.42

Rad H. (m) = 0.04

Velocidad = 0.48 m/s

h v = 0.01 m.

E = Yn + hv = 0.07 m.

Calculo de borde Libre .

BL = Yn /3 = 0.020 m.

Usaremos : BL = 0.02 m

Resultados:

B.L. 0.02 m. 0.08 m.

Yn 0.06 m.b = 0.30 m.

b