AshBM-EL

download AshBM-EL

of 2

Transcript of AshBM-EL

  • 7/31/2019 AshBM-EL

    1/2

    HOW TO ORDER

    30 EL 60 R 040 0/250F XNH

    Dial Size: 3Code 30

    Case Style: EL

    Stem Connection: 12 NPT Code 60

    Stem Location: Rear Code R

    Stem Length: 4Code 040

    Range: Code 0/250F

    Options: Stainless steel tag

    EL Series Bimetal Thermometers

    FEATURES

    Silicone liquid fill

    1% full span accuracy (ASME B40.3 Grade A)

    Maximum ambient temp. is 150F (65C)

    Hermetically sealed case to prevent entryof moisture, interior corrosion and coilfreeze-up.

    External adjustment permits zero reset fromoutside the case.

    Maxivison dial allows readability from anyangle without parallax error.

    Silicone coil dampening (up to 400F)provides vibration dampening and improvesresponse time.

    All-welded stainless steel construction Durable polycarbonate window

    Protection IP 65

    Five year limited warranty

    SPECIFICATIONS

    Ashcroft

    Series: EL

    Dial Sizes: 3, 5

    Stem Length: 21224(1)

    Case & Stem: 304 stainless steel, hermeticallysealed

    Stem Dia: .250

    Window: Durable polycarbonate window

    Dial: Maxivision, black figures on whitebackground

    Pointer: Black

    Connection: 12 NPT and 12 NPT union

    ConnectionLocation: Everyangle(2), Rear

    Ranges: -40/160F 50/550F-20/120C 0/300C

    Options: Code DescriptionC4 Individual calibration cert.XCS Dual scaleXDM Dial markingXNH Stainless steel tagXNN Paper tagX3B 38 stem dia. with 12 NPTX02 14 NPT when 12 NPT is standard(3)

    (1) Special or longer length available, consult factory(2) Everyangle NA on 3 dial(3) Only available on rear connection

    Thermowells must be used on all pressure orvelocity applications, to protect the stem ofthermometer from corrosion and physicaldamage, and to facilitate removal of thethermometer without disturbing the process.

    Maximum ambient temperature is 150F (65C).

    Ashcro ft Inc ., 250 East Main S treet, S tratfor d, CT 06614 USATel: 203-378-8281 Fax: 203-385-0408

    email: [email protected] www.ashcroft.com

    All specific ations are subject to change without notice .All sales subjec t to standard ter ms and conditions .

    Ashcroft Inc. 2011 03/11BULLETIN BM-EL

  • 7/31/2019 AshBM-EL

    2/2

    EL Series selection table

    EL Series Bimetal Thermometers

    Ashcro ft Inc ., 250 East Main S treet, S tratfor d, CT 06614 USATel: 203-378-8281 Fax: 203-385-0408

    email: [email protected] www.ashcroft.com

    All specific ations are subject to change without notice .All sales subjec t to standard ter ms and conditions .

    Ashcroft Inc. 2011 03/11

    Case Size Stem Stem Lengths Temperature RangeAvailable

    SDial Code Style Conn. Code Location Code Length Code F* Fig. C Fig.

    Code (inches) Fahrenheit/ Div.

    Inter. Celsius/ Div.

    Inter.

    40/1602 20

    10/110 2 10

    12 NPT 60 Rear R212 025 20/120 20/120 2 20

    4 040 30/130 1 10 0/50 1 53 30

    6 060 0/200 0/100 1 10

    EL 9 090 0/250 2 20 10/150 2 2012 120 50/300

    12 NPT42

    Everyangle E 15 1505 50 12NPT 60

    18 180 50/550 5 50 5 5012 NPT 60 Rear R 24 240

    EL Dimensions

    *Dual scale ranges available for all standard F rangesUse Ashcroft Duratemp thermometers for ranges aboveand below those listed above.

    Minimum stem length for Everyangle is 4.

    NOTES:1. Figures in parenthesis ( ) are in millimeters. All other dimensions are in inches.2. Standard S dimensions are 212, 4, 6, 9, 12, 15, 18 and 24 inches. Standard stem diameter is 14 inch.3. Add 1 oz. for every 2 inches of stem length.

    Overtemperature limits

    Top of Range F Maximum

    Overpressure

    up to 160 100% of span

    160/300 300F

    300/550 550FWeight in

    Case Dial Connection ounces(3)

    Series Size LocationA B C G H S NPT Hex S 212

    EL 3 Rear 3532 1932 38 (2) 12 78 7

    (80) (15) (8)

    EL 5 Rear 5132 2332 38 (2) 12 78 16

    (128) (18) (8)

    EL 5 Everyangle 5116 2332 178 32132 (2) 12 78 25

    (128) (18) (48) (93)

    G

    B

    H

    S

    A

    S

    A

    C

    B

    EL Series dual scale rangesInner Outer

    40/160F and 40/70C20/120F and 30/50C

    0/200F and 20/94C

    0/250F and 20/120C

    30/130F and 0/55C

    50/300F and 10/150C

    50/550F and 10/290C

    BULLETIN BM-EL

    DIMENSIONS

    Union