5
CARACTERISTICAS DE LA BOMBA CARACTERÍSTICAS DEL FLUIDO SUCCIÓN DESCARGA CAUDAL POR BOMBA Q (Mbpd) = 25.00 PRESIÓN DE SUCCIÓN PRESIÓN DE DESCARGA 46.00 3.00 15.00 Q (l/s) = 46.01 Ps (kpa) = 294.20 Pd (kpa) = 1,471.00 1.62 Ps (psi) = 42.67 Pd (psi) = 213.35 Q (gpm) = 729.25 Ps (ft) = 99.46 Pd (ft) = 497.31 Ps (m) = 30.32 Pd (m) = 151.58 FACTOR DE SEGURIDAD Fs (%) = 10.00 LONGITUD DE LA TUBERÍA LONGITUD DE LA TUBERÍA Fs = 1.10 H1 (m) = 10.00 H1 (m) = 5.00 H1 (ft) = 32.81 H1 (ft) = 16.40 GRAVEDAD ESPECIFICA S.G. 0.991 ALTURA ALTURA H1 (m) = 5.00 H2 (m) = 15.00 DENSIDAD H1 (ft) = 16.40 H2 (ft) = 49.21 990.95 61.87 DIÁMETRO DE LA TUBERÍA DIÁMETRO DE LA TUBERÍA D (in) = 12.00 D (in) = 12.00 PRESIÓN DE VAPOR D (ft) = 1.00 D (ft) = 1.00 0.03 Pv (kpa) = 2.94 VELOCIDAD VELOCIDAD Pv (psi) = 0.43 V1 (m/s) = 0.70 V1 (m/s) = 0.70 Pv (psia) = 15.13 V1 (ft/s) = 2.29 V1 (ft/s) = 2.29 Pv (ft) = 35.26 Pv (m) = 10.75 L/D VÁLVULAS Y ACCESORIOS L/D VÁLVULAS Y ACCESORIOS L/D (ft) = 608.00 L/D (ft) = 208.00 PRESIÓN ATMOSFÉRICA L/D (m) = 185.32 L/D (m) = 63.40 Patm (psi) = 14.7 L/D (Psi) = 260.83 L/D (Psi) = 89.23 Patm (ft) = 34.27 Patm (m) = 10.44 COEFICIENTE DE RESISTENCIA K COEFICIENTE DE RESISTENCIA K K = 2.75 K = 2.75 LONGITUD TOTAL DE LA TUBERÍA LONGITUD TOTAL DE LA TUBERÍA Hf (ft) = 809.96 Hf (ft) = 426.38 Hf (m) = 246.88 Hf (m) = 129.96 Hf (Psi) = 347.48 Hf (Psi) = 182.92 CAIDA DE PRESIÓN /100 ft CAIDA DE PRESIÓN /100 ft DP (Psig) = 0.06 DP (Psig) = 0.06 DP (ft) = 0.15 DP (ft) = 0.15 CAIDA DE PRESIÓN A LONGITUD TOTAL CAIDA DE PRESIÓN A LONGITUD TOTAL DP (Psig) = 0.50 DP (Psig) = 0.27 DP (ft) = 1.18 DP (ft) = 0.62 OTROS DATOS EFICIENCIA DE LA BOMBA EFICIENCIA DEL MOTOR (90-93%) Eo (%) = 70.00 E1 (%) = 92.00 Eo = 0.70 E1 = 0.92 ALTURAS FACTOR DE FRICCIÓN ALTURA MAYOR (m) = 15.00 f = 0.0180 ALTURA MENOR (m) = 5.00 ALTURA MAYOR (ft) = 49.21 ALTURA MENOR (ft) = 16.40 SUCCIÓN POSITIVA (1) SUCCIÓN NEGATIVA(2) SUCCIÓN POSITIVA(3) EL TANQUE ESTÁ POR ENCIMA EL TANQUE ESTÁ POR DEBAJO EL TANQUE ESTÁ POR ENCIMA DE LA SUCCIÓN DE LA BOMBA DE LA SUCCIÓN DE LA BOMBA DE LA SUCCIÓN DE LA BOMBA TANQUE ATMOSFÉRICO TANQUE ATMOSFÉRICO TANQUE PRESURIZADO ft m ft m ft m hs = 34.27 10.44 hs = 34.27 10.44 hs = 133.73 40.76 hv = -35.26 -10.75 hv = -35.26 -10.75 hv = -35.26 -10.75 hz = 32.81 10.00 hz = -32.81 -10.00 hz = 32.81 10.00 hf = -1.80 -0.55 hf = -1.80 -0.55 hf = -1.80 -0.55 NPSH DISPONIBLE NPSHd (ft) = 30.02 NPSHd (ft) = -35.60 NPSHd (ft) = 129.48 NPSHd (m) = 9.15 NPSHd (m) = -10.85 NPSHd (m) = 39.47 NPSHd (Psi) = 12.88 NPSHd (Psi) = -15.27 NPSHd (Psi) = 55.55 NPSH REQUERIDO NPSHr (ft) = 16.49 NPSHr (ft) = 16.49 NPSHr (ft) = 16.49 NPSHr (m) = 5.03 NPSHr (m) = 5.03 NPSHr (m) = 5.03 NPSHr (Psi) = 7.07 NPSHr (Psi) = 7.07 NPSHr (Psi) = 7.07 ACEPTABLE NO ACEPTABLE ACEPTABLE CARGA POR FRICCIÓN CAIDA DE PRESIÓN TOTAL Hf (ft) = 1.80 Hf (m) = 0.55 Hf (Psi) = 0.77 CARGA ESTÁTICA Hstat (ft) = 430.09 Hstat (m) = 131.09 Hstat (psi) = 184.51 CARGA DINÁMICA Hdyn (ft) = 0.08 Hdyn (m) = 0.02 Hdyn (psi) = 0.04 CARGA TOTAL Hp (ft) = 431.97 Hp (m) = 131.66 Hp (psi) = 185.32 POTENCIA HIDRÁULICA ALTURA CAUDAL DENSIDAD S.G. HHP (hp) = 86.83 86.72 POTENCIA AL FRENO ALTURA CAUDAL DENSIDAD S.G. BHP (Hp) = 124.04 123.88 POTENCIA DEL MOTOR HP (Hp) = 134.83 POTENCIA DEL MOTOR COMERCIAL INMEDIATO SUPERIOR HP (Hp) = 150 Q (dm 3 /s)= Ps (kg/cm 2 ) = Pd (kg/cm 2 ) = Q (ft 3 /s) = D (kg/m 3 ) = D (lb/ft 3 ) = Pv (kg/cm 2 ) =

description

DISEÑO DE BOMBA CENTRIFUGA

Transcript of BOMBA.xlsx

Page 1: BOMBA.xlsx

CARACTERISTICAS DE LA BOMBA CARACTERÍSTICAS DEL FLUIDO

SUCCIÓN DESCARGA CAUDAL POR BOMBAQ (Mbpd) = 25.00

PRESIÓN DE SUCCIÓN PRESIÓN DE DESCARGA 46.00

3.00 15.00 Q (l/s) = 46.01

Ps (kpa) = 294.20 Pd (kpa) = 1,471.00 1.62Ps (psi) = 42.67 Pd (psi) = 213.35 Q (gpm) = 729.25Ps (ft) = 99.46 Pd (ft) = 497.31Ps (m) = 30.32 Pd (m) = 151.58 FACTOR DE SEGURIDAD

Fs (%) = 10.00LONGITUD DE LA TUBERÍA LONGITUD DE LA TUBERÍA Fs = 1.10H1 (m) = 10.00 H1 (m) = 5.00H1 (ft) = 32.81 H1 (ft) = 16.40 GRAVEDAD ESPECIFICA

S.G. 0.991ALTURA ALTURA

H1 (m) = 5.00 H2 (m) = 15.00 DENSIDAD

H1 (ft) = 16.40 H2 (ft) = 49.21 990.95

61.87

DIÁMETRO DE LA TUBERÍA DIÁMETRO DE LA TUBERÍAD (in) = 12.00 D (in) = 12.00 PRESIÓN DE VAPOR

D (ft) = 1.00 D (ft) = 1.00 0.03

Pv (kpa) = 2.94VELOCIDAD VELOCIDAD Pv (psi) = 0.43

V1 (m/s) = 0.70 V1 (m/s) = 0.70 Pv (psia) = 15.13V1 (ft/s) = 2.29 V1 (ft/s) = 2.29 Pv (ft) = 35.26

Pv (m) = 10.75L/D VÁLVULAS Y ACCESORIOS L/D VÁLVULAS Y ACCESORIOS

L/D (ft) = 608.00 L/D (ft) = 208.00 PRESIÓN ATMOSFÉRICAL/D (m) = 185.32 L/D (m) = 63.40 Patm (psi) = 14.7

L/D (Psi) = 260.83 L/D (Psi) = 89.23 Patm (ft) = 34.27Patm (m) = 10.44

COEFICIENTE DE RESISTENCIA K COEFICIENTE DE RESISTENCIA KK = 2.75 K = 2.75

LONGITUD TOTAL DE LA TUBERÍA LONGITUD TOTAL DE LA TUBERÍAHf (ft) = 809.96 Hf (ft) = 426.38Hf (m) = 246.88 Hf (m) = 129.96

Hf (Psi) = 347.48 Hf (Psi) = 182.92

CAIDA DE PRESIÓN /100 ft CAIDA DE PRESIÓN /100 ftDP (Psig) = 0.06 DP (Psig) = 0.06

DP (ft) = 0.15 DP (ft) = 0.15

CAIDA DE PRESIÓN A LONGITUD TOTAL CAIDA DE PRESIÓN A LONGITUD TOTALDP (Psig) = 0.50 DP (Psig) = 0.27

DP (ft) = 1.18 DP (ft) = 0.62

OTROS DATOS

EFICIENCIA DE LA BOMBA EFICIENCIA DEL MOTOR (90-93%)Eo (%) = 70.00 E1 (%) = 92.00

Eo = 0.70 E1 = 0.92

ALTURAS FACTOR DE FRICCIÓNALTURA MAYOR (m) = 15.00 f = 0.0180ALTURA MENOR (m) = 5.00ALTURA MAYOR (ft) = 49.21ALTURA MENOR (ft) = 16.40

SUCCIÓN POSITIVA (1) SUCCIÓN NEGATIVA(2) SUCCIÓN POSITIVA(3)

EL TANQUE ESTÁ POR ENCIMA EL TANQUE ESTÁ POR DEBAJO EL TANQUE ESTÁ POR ENCIMADE LA SUCCIÓN DE LA BOMBA DE LA SUCCIÓN DE LA BOMBA DE LA SUCCIÓN DE LA BOMBA

TANQUE ATMOSFÉRICO TANQUE ATMOSFÉRICO TANQUE PRESURIZADO

ft m ft m ft mhs = 34.27 10.44 hs = 34.27 10.44 hs = 133.73 40.76hv = -35.26 -10.75 hv = -35.26 -10.75 hv = -35.26 -10.75hz = 32.81 10.00 hz = -32.81 -10.00 hz = 32.81 10.00hf = -1.80 -0.55 hf = -1.80 -0.55 hf = -1.80 -0.55

NPSH DISPONIBLE

NPSHd (ft) = 30.02 NPSHd (ft) = -35.60 NPSHd (ft) = 129.48

NPSHd (m) = 9.15 NPSHd (m) = -10.85 NPSHd (m) = 39.47NPSHd (Psi) = 12.88 NPSHd (Psi) = -15.27 NPSHd (Psi) = 55.55

NPSH REQUERIDONPSHr (ft) = 16.49 NPSHr (ft) = 16.49 NPSHr (ft) = 16.49NPSHr (m) = 5.03 NPSHr (m) = 5.03 NPSHr (m) = 5.03NPSHr (Psi) = 7.07 NPSHr (Psi) = 7.07 NPSHr (Psi) = 7.07

ACEPTABLE NO ACEPTABLE ACEPTABLE

CARGA POR FRICCIÓNCAIDA DE PRESIÓN TOTAL

Hf (ft) = 1.80Hf (m) = 0.55Hf (Psi) = 0.77

CARGA ESTÁTICAHstat (ft) = 430.09Hstat (m) = 131.09Hstat (psi) = 184.51

CARGA DINÁMICAHdyn (ft) = 0.08Hdyn (m) = 0.02Hdyn (psi) = 0.04

CARGA TOTAL Hp (ft) = 431.97

Hp (m) = 131.66Hp (psi) = 185.32

POTENCIA HIDRÁULICAALTURACAUDAL

DENSIDAD S.G.

HHP (hp) = 86.83 86.72

POTENCIA AL FRENOALTURACAUDAL

DENSIDAD S.G.

BHP (Hp) = 124.04 123.88

POTENCIA DEL MOTOR

HP (Hp) = 134.83

POTENCIA DEL MOTOR COMERCIAL INMEDIATO SUPERIOR

HP (Hp) = 150

Q (dm3/s)=

Ps (kg/cm2) = Pd (kg/cm2) =

Q (ft3/s) =

D (kg/m3) =

D (lb/ft3) =

Pv (kg/cm2) =

K22
ETMASPC15: PRESIÓN DE VAPOR = PRESIÓN DE SATURACIÓN = PRESIÓN DE EBULLICIÓN
C29
ING. EMMANUEL: IR A LA PESTAÑA TABLA L/D Y SELECCIONAR LAS VÁLVULAS Y ACCESORIOS CORRESPONDIENTES A LA SUCCIÓN
G29
ING. EMMANUEL: IR A LA PESTAÑA TABLA L/D Y SELECCIONAR LAS VÁLVULAS Y ACCESORIOS CORRESPONDIENTES A LA DESCARGA
C34
ING. EMMANUEL: Hallar el valor de K en la pestaña GRAFICA K
G34
ING. EMMANUEL: Hallar el valor de K en la pestaña GRAFICA K
Page 2: BOMBA.xlsx

NOTA: INDICAR EN LAS CASILLAS DE CANTIDADES, EL NÚMERO DE ACCESORIOS QUE CONTENGA SU SISTEMA DE BOMBEO

TABLA 3: LONGITUDES EQUIVALENTES EN ft (MPR-A-001) PEMEX

SUCCIÓNDISPOSITIVO DESCRIPCIÓN L/D CANT.

100 % Abierta 340 0

100 % Abierta 450 0

100 % Abierta 1.75 0

100 % Abierta 1.45 0

Válvula de ángulo de asiento y tapón 100 % Abierta 1.45 0

100 % Abierta 200 0

Válvula de compuerta 100 % Abierta 13 1Válvula de compuerta 75 % Abierta 35 0Válvula de compuerta 50 % Abierta 160 0Válvula de compuerta 25 % Abierta 900 0Válvula de retención 100 % Abierta 135 1Válvula de retención 100 % Abierta 450 0Válvula de retención 100 % Abierta 200 0Válvula de retención 100 % Abierta 150 0

100 % Abierta 420 0

100 % Abierta 75 0

100 % Abierta 18 0

80 % Abierta 44 0

80 % Abierta 140 0

Codo 90° 30 10Codo 45° 16 5Codo 90° de radio largo 20 0Codo 90° roscado 50 0Codo 45° roscado 26 0Codo de esquina cuadrada 5.70 0Tee con flujo en línea recta 20 1Tee con flujo en línea derivada 60 1Curva en "U" estrecha 50 0

Válvula de globo lineal de asiento y tapón

Válvula de globo lineal con perno guiado en disco

Válvula de globo "Y" con vástago a 60° del flujo.

Válvula de globo "Y" con vástago a 45° del flujo.

Válvula de ángulo con perno guiado en disco

Válvulas de pie con coladera con disco y varilla

Válvulas de pie con coladera con disco y bisagra no metálica

Válvulas auxiliares recta con tapón regular y área al puerto igual al área de la tubería

Válvulas auxiliares tres vías con tapón regular y área al puerto igual al área de la tubería (flujo en línea recta)

Válvulas auxiliares tres vías con tapón regular y área al puerto igual al área de la tubería (flujo en línea derivada)

Page 3: BOMBA.xlsx

NOTA: INDICAR EN LAS CASILLAS DE CANTIDADES, EL NÚMERO DE ACCESORIOS QUE CONTENGA SU SISTEMA DE BOMBEO

TABLA 3: LONGITUDES EQUIVALENTES EN ft (MPR-A-001) PEMEX

SUCCIÓN DESCARGATOTAL CANT. TOTAL

0 0 0

0 0 0

0 0 0

0 0 0

0 0 0

0 0 0

13 1 130 0 00 0 00 0 0

135 1 1350 0 00 0 00 0 0

0 0 0

0 0 0

0 0 0

0 0 0

0 0 0

300 2 6080 0 00 0 00 0 00 0 00 0 0

20 0 060 0 00 0 0

608.00 208.00

Page 4: BOMBA.xlsx

NOTA: INDICAR EN LAS CASILLAS DE CANTIDADES, EL NÚMERO DE ACCESORIOS QUE CONTENGA SU SISTEMA DE BOMBEO

GRÁFICA 4: LONGITUD EQUIVALENTE L, RELACIÓN L/D Y COEFICIENTE DE RESISTENCIA K. (MPR-A-001) PEMEX

Page 5: BOMBA.xlsx

NOTA: INDICAR EN LAS CASILLAS DE CANTIDADES, EL NÚMERO DE ACCESORIOS QUE CONTENGA SU SISTEMA DE BOMBEO

GRÁFICA 4: LONGITUD EQUIVALENTE L, RELACIÓN L/D Y COEFICIENTE DE RESISTENCIA K. (MPR-A-001) PEMEX