Components:
1. Entrada de edificio (acometida)
2. Building entrance (Rush)
3. Vertical or Backbone Cabling
4. Telecommunications Closet
5. Horizontal Cabling
6. Workspace
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
4/61
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
5/61
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
6/61
All major standards specify that each hardware connection drive musthave a unique identification.
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
7/61
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
8/61
IEC (International Committee Electrotechnical) 17763 recommends thatinformation regarding the system of structured cabling is maintained in adatabase with five fields:
Field 1 General location
Field 2 Specific location
Field 3 The component identifier
Field 4 Port number
Field 5 Physical data
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
9/61
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
10/61
The registration of a cable sets a cable to go from point A to point B.
Installation of the cables can include:
* Cable type (fiber or copper)
* Manufacturer, coating and marking the core
* Number of conductors and pairs available
* Notes on connections and grounding
* Performance data cable
* Certification documents.
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
11/61
* Type of shot, used and available
* Cable Features* Pairs available within the cables (telephony)
* If the cable is connected or not
* Notes on connections and grounding
* Notes on the journey that makes the cable
Records regarding the type and location of outlets of telecommunications:
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
12/61
* Number and type of cables
* Information on routes that feed
* Diagrams racks
* Notes on food, backup power and
environmental controls.
To store data can include the following:
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
13/61
The cables and wiring stairs required be documented including:
* The nature of the route
* The attributes of the route
* Records of installed cables
* Details of materials required
* Information regarding the grounding,
earthing and grounding joined
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
14/61
It is important to record data on each of the devices that need to;details, as device type and model number
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
15/61
Cable access is not connected or marked for future use is consideredto be abandoned.
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
16/61
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
17/61
TIA/EIA-568-B: Standard wiring.TIA/EIA-569-A: Routes and spaces of cables.TIA/EIA-570-A: Wiring residential and commercial child.TIA/EIA-606: Management standards.TIA/EIA-607: Grounding and connection requirements.
Standards which will make it possible to install cabling plant structuredgeneric that you can operate any application of voice or data:
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
18/61
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
19/61
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
20/61
It is an area within a building that hosts system wiring oftelecommunications equipment.
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
21/61
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
22/61
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
23/61
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
24/61
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
25/61
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
26/61
Important elements:
Advanced connection panels can help to increase the ability to manipulate
the density wiring.
Devices and cabling management techniques also play an important role inthe setting of a high density wiring.
Appropriate signage.
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
27/61
Telecommunications rooms should be located away from sources of
electromagnetic interference.
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
28/61
Location of computers both rack and walls in such a way that does not
disrupt the step.
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
29/61
Grounding that consists of a bar is buried in the ground or a ground thatconnects to a terminal main land on the driver's main groundingelectrode.
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
30/61
Hechas de cobre y ser de 50 mm (2 pulgadas) de ancho por 6 mm (0,25pulgadas) de grosor, y de la longitud necesaria para conectar los cables deunin a tierra.
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
31/61
Made of copper and must have a minimum size of 100 mm (4 inches) inwidth and 6 mm (0.25 inches) thick.
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
32/61
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
33/61
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
34/61
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
35/61
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
36/61
Telecommunications room must have sufficient heating, ventilation and air
conditioning (HVAC)
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
37/61
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
38/61
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
39/61
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
40/61
The raised floors and false ceilings can also support patch panels. Usually used to
house the consolidation points or multi-user telecommunications connections
(MUTOs)
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
41/61
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
42/61
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
43/61
A direct cable connection is one that passed between the same pins on both
ends.
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
44/61
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
45/61
Communications Room types:
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
46/61
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
47/61
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
48/61
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
49/61
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
50/61
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
51/61
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
52/61
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
53/61
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
54/61
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
55/61
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
56/61
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
57/61
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
58/61
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
59/61
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
60/61
-
8/8/2019 SENA_PRESENTACIN_INGLS_CAPTULO7_PANDUIT_LARED38110_
61/61