Ok Muro de Contencion Tipo01

download Ok Muro de Contencion Tipo01

of 2

description

www

Transcript of Ok Muro de Contencion Tipo01

  • ANCHO SOBRECARGA

    MURO 0.400 0.500 T/M2

    T

    DATOS (MTS)

    SISMO

    Bz= 1.80 mts 0.50

    T = 0.40 mts DENSIDAD ALTURA

    hz= 0.50 mts 1.88 Tn/m3 P2 Hp 3.10

    Hp= 3.10 mts Dp 3.10 Fp ANGULO FRICCION

    E = 0.25 mts 33

    G = 0.00 mts

    Dp= 3.10 mts P3 P5

    Fp= 3.10 6

    M = 0.70 mts M E G N

    N = 0.45 mts Hd 1.200 P1 hz 0.50

    Hd= 1.20 mts

    B

    BASE 1.804

    Peso especifico del concreto (w)= 2.40 T/m3

    Peso especifico suelo (&)= 1.88 T/m3

    Angulo de Friccion ()= 32.74 Grados

    Presion admisible de terreno (q)= 1.42 Kg/cm2

    Coeficiente Friccion (u) 0.60 0.52

    S/C 0.50 T/m2

    Elemento Peso (Ton) Brazo (m) Mr = P*X h s/c 0.266 mts

    1 2.16 0.90 1.95

    2 2.98 1.15 3.42 Ka 0.298

    3 0.93 0.87 0.81

    4 0.00 1.35 0.00 Pa 2.016

    5 2.64 1.58 4.17

    S/C 0.23 1.58 0.36 Ps/c 0.149

    Total 8.94 10.71

    Ea 3.63 1.20 4.35 u 0.600

    S/C 0.54 1.80 0.97

    Total 4.16 5.32

    ** Si consideramos el empuje pasivo Ep para aumentar la fuerza estabilizadora construyendo un

    diente de C

    Ep = 4.54 Tn/m

    FS = M estabiliz = 2.01 >1.5 CONFORME

    VERIFICACION DE ESTABILIDAD

    VERIFICACION DE MUROS DE CONTENCIN - TIPO 01

    CHEQUEO AL VOLTEO

  • VERIFICACION DE MUROS DE CONTENCIN - TIPO 01

    M volteo

    FS = u*Fv +Ep 2.38 >1.50 CONFORME

    Fh

    X = ( Mr - Ma ) 0.60

    P

    e = B/2 - X 0.30

    B/6 > e = 0.30 >e CONFORME

    q1 = 9.89 tn/m2 CONFORME

    q2 = 0.02 tn/m2 CONFORME

    q